• Title/Summary/Keyword: Fixed dental prostheses

Search Result 169, Processing Time 0.022 seconds

Clinical study on the comparison of gold and zirconia wear in an implant-supported fixed prosthesis (임플란트 지지 고정성 보철물에서 금과 지르코니아의 마모 비교에 대한 임상 연구)

  • Kim, Jee-Hwan;Yang, Seung-Won;Oh, NamSik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.252-259
    • /
    • 2017
  • Purpose: The purpose of this study was to compare and analyze the wear of a prosthesis for 6 months after restoration with implant-supported fixed dental prosthesis made of either zirconia or gold. Materials and Methods: This study was conducted on patients requiring implant-supported fixed dental prostheses on first or second molar from January, 2015 to January, 2016. A total of 47 prostheses and antagonists were examined. Occlusal surface was recorded by impression of each prosthesis and antagonist 1 week and 6 months after prosthesis delivery. The digital files were created by impression scan. Occlusal shapes of 1 week and 6 months were compared and wear of prostheses and antagonists was analyzed. The Mann-Whitney test was used to analyzed the result data underwent normality test using SPSS (Version 23.0, IBM Corporation) Results: Mann-Whitney test revealed that there was no statistically significant difference in the median amount of mean vertical wear for 6 months in zirconia ($50.84{\mu}m$) and gold ($42.84{\mu}m$) prostheses (P > 0.05). When the opposing teeth were natural, the median amount of mean vertical wear of zirconia and gold prostheses was $47.72{\mu}m$ and $41.97{\mu}m$, respectively, and the median amount of mean vertical wear of enamel was $47.26{\mu}m$ and $44.59{\mu}m$, respectively. Statistical analysis showed no significant difference (P > 0.05). Conclusion: Despite the short study period and the small number of experimental groups, zirconia and gold showed no significant difference in wear during the first 6 months. Opposing natural enamel also showed no significant difference in the wear.

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

Fiber-reinforced composite resin bridges: an alternative method to treat root-fractured teeth

  • Heo, Gun;Lee, Eun-Hye;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.1
    • /
    • pp.8.1-8.9
    • /
    • 2020
  • The replacement of missing teeth, especially in the anterior region, is an essential part of dental practice. Fiber-reinforced composite resin bridges are a conservative alternative to conventional fixed dental prostheses or implants. It is a minimally invasive, reversible technique that can be completed in a single visit. The two cases presented herein exemplify the treatment of root-fractured anterior teeth with a natural pontic immediately after extraction.

Design of Bristle Shapes using 3-dimensional Teeth Data for the Periodontally Involved Patients

  • Kim, Hyun-Jun;Suh, Myung-Won;Bae, Jong-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2006
  • Bristles for the prosthetic and periodontally involved patients are investigated based on previous studies. Specifically, the ideal location and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis were investigated. 3D (Three-Dimensional) scanner was used to develop 3D visual models of bristles and teeth. These models were used for designing the ideal bristles. In the design, the interproximal area of dental arch and bristle must be maximized and the standard teeth may have to be chosen from many gypsum molds. During the design process the factors that influence plaque removal by the bristle were considered.

Accuracy of several implant bite registration techniques: an in-vitro pilot study

  • Park, Do-Hyun;Park, Ji-Man;Choi, Jae-Won;Kang, Eun-Sook;Bae, Eun-Bin;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.341-349
    • /
    • 2017
  • PURPOSE. This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS. Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS. The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION. Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.

Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system

  • Lee, Jeong-Yol;Choi, Sang-Jin;Kim, Min-Soo;Kim, Ha-Young;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.118-125
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate the effect of the span length on the fit of zirconia framework fabricated using CAD/CAM system. MATERIALS AND METHODS. Abutments for single, 4-unit and 6-unit fixed partial prostheses were fabricated. Ten zirconia frameworks were fabricated for each group. The marginal and internal gap were presented by means of replica technique and measured by measuring microscope ($AXIO^{(R)}$, Carl Zeiss, Rochester, NY) and software (I-$solution^{(R)}$, IMT i-solution Inc., Vancouver, BC, Canada). The results were statistically analyzed by multivariate analysis test and Dunnett T3 test for post hoc test (${\alpha}$=.05). RESULTS. There were statistically significant differences at 2, 4, 7, 8 points (mesio-distal section) and b, d, e, f, g (labio-lingual section). In some marginal reference points of 6-unit group (P<.05), the marginal gap were larger than 120 ${\mu}m$. CONCLUSION. Span length of zirconia core may have an influence on marginal and internal fit. Within the limitation of this study, the increase of span length of zirconia framework of 6 or more-unit fixed partial denture may decrease the marginal and internal fit.

Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis (Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례)

  • Kim, Seong-Mo;Park, Jin-Hong;Ryu, Jae-Jun;Shin, Sang Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.126-133
    • /
    • 2018
  • The development of cone beam computerized tomography (CBCT) allows three-dimensional analysis of the patient's anatomy. The surgical guide is a combination of CBCT, computer-aided design/computer-aided manufacturing (CAD/CAM) and implant diagnostics software, which allows well planned prostheses design and ideal implant placement. Guided surgery minimizes possible anatomical damage and allows for more reproducible treatment planning. In this case, the operation time was shortened by using a surgical guide for multiple implants placement in a fully edentulous patient. Immediate loading were performed more easily using preliminary preparation of provisional prosthesis. The patient was satisfied with improved esthetics and chewing function.

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

LONGITUDINAL CLINICAL STUDY ON THE EFFICACY OF OSSEOINTEGRATED DENTAL IMPLANTS IN PARTIALLY EDENTULOUS KOREAN PATIENTS: AN 8-YEAR PROSPECTIVE STUDY

  • Han Dong-Hoo;Bae Hanna Eun-Kyong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.698-708
    • /
    • 2001
  • This study was to evaluate the clinical evidence for the success and the predictability of the osseointegrated dental implants in the partially edentulous Korean patients. 201 patients have received total of 502 Branemark implants, which were restored with either single or multiunit fixed superstructures at the Implants Clinic, Yonsei University Dental Hospital. The clinical and radiographic evaluations carried out on the patients for maximum 8 years were assessed annually for peri-implant inflammation, implant mobility (PTV), Plaque Index (PI), Gingival Index (GI), Bleeding on Probing (BOP), Keratinized Mucosa width and any changes in the surrounding bone level. The radiographs were taken at completion of the restoration, and annually thereafter. On the last recall appointments the patients filled a questionnaire consist of 29 questions in four categories. The cumulative non-failure rate of success was 93.9%. The first year mean bone loss was 0.3mm and less than 0.2mm annually thereafter. The periodontal parameters, keratinized tissue width and periotest values stabilized after initial changes in the first few years. The questionnaire has shown general satisfactory responses in all four aspect of dental implants treatment, including chewing efficacy, comfort, aesthetics and speech. The results support the predictability and success of the long-term rehabilitation of implant supported prostheses in partially edentulous Korean patients.

  • PDF

Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report (임플란트 지지 나사-시멘트 유지형 보철물에서 보철물-지대주 제거 후 변연부 연마의 효과: 증례보고)

  • Kim, Mijoo;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.239-243
    • /
    • 2020
  • When the marginal fit of fixed dental prosthesis decreases, biological and technical complications, such as plaque accumulation, periodontal disease, hypersensitivity, components fracture, cement loss, can happen. The complications affect the long-term success and survival of prostheses. This case report describes a clinical procedure to minimize the marginal gap of implant-supported screw-and-cement retained prosthesis by removing prosthesis-abutment complex and burnishing the interface area. The marginal gap was measured before and after the burnishing using a stereomicroscope and compared. This technique improves the marginal fit, thereby contributing the longevity of the prosthesis.