• Title/Summary/Keyword: Fixed bed

Search Result 516, Processing Time 0.028 seconds

Studies on syngas production and gas engine generation of soild waste gasification in the fixed bed gasification melting furnace (고정층 가스화 용융로에서의 고상폐기물 가스화 합성가스 생산 및 가스엔진 발전 연구)

  • Gu, Jae-Hoi;Kim, Su-Hyun;Yoo, Young-Don;Yun, Yong-Seung;Lee, Hyup-Hee;Nam, Sang-Ik;Yoon, Jae-Kwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.717-720
    • /
    • 2007
  • The 3 ton/day-scale pilot plant consists of compressor, feed channel, fixed bed type gasification & melting furnace, quench scrubber, demister, flare stack and gas engine. Syngas composition of gasification using the 35.50(waste I), 4.34%(wasteII) moisture-containing solid waste showed waste I CO 25-35%, 20-40% hydrogen, waste II 25-35%, 20-30% hydrogen. Gasification melting furnace was operated $1,500{\sim}1,600^{\cdot}C$. Gas engine was generated $35{\sim}40$ kW as waste gasification syngas.

  • PDF

Treatment of Textile Wastewater by Anaerobic Sludge and Aerobic Fixed-Bed Biofilm Reactor (혐기성 슬러지 공정과 호기성 고정생물막 공정을 이용한 염색폐수 처리)

  • 박영식;문정현
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.55-63
    • /
    • 2002
  • This study was carried out to treat textile wastewater using anaerobic sludge and aerobic fixed-bed biofilm reactor immobilized with Bacillus sp. dominated activated sludge(Bacillus sp. fraction : 81.5%). The range of influent con-centration of SCOD and soluble color were 1032-1507 mg/1, and 1239-1854 degree, respectively. Continuous treatment experiments were performed with variation of textile wastewater ratio at a same HRT. When textile wastewater ratio was 100%(HRT : 24 hours), The removal efficiency of SCOD and soluble color were 88% and 78%, respectively. When compare aerobic reactor of this study that was immobilized with Bacillus sp. dominated activated sludge to other study that was immobilized with activated sludge, SCOD and soluble color removal efficiency of this study showed a little higher efficiency than immobilized with activated sludge. The Bacillus sp. fraction of initial condition was 81.5%), but the fraction after operation was decreased to 31.8%).

Adsorption Analysis of Benzene Vapor in a Fixed-Bed of Granular Activated Carbon (활성탄 충전층에서 벤젠 증기의 흡착특성)

  • Kim, Seong-Soo;Kim, Jong-Hyun;Park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.495-500
    • /
    • 2009
  • Activated carbon was used as an adsorbent to capture benzene vapor from gaseous stream of nitrogen in a fixed-bed to obtain the breakthrough data. The deactivation model is used to analyze the adsorption kinetics of benzene vapor using the experimental breakthrough data. The experimental breakthrough data are fitted very well to the deactivation model than the adsorption isotherm models in the literature.

Assessment of PIV to Measure the Flow Field Over a Fixed Dune Bed (언덕이 있는 하상유동 계측을 통한 PTV기법의 수력학적 적용연구)

  • Hyun B.-S.;Balachandar R.;Patel V. C.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.217-220
    • /
    • 2002
  • The assessment of PIV to measure the mean velocity and turbulence was carried out over a train of fixed two-dimensional dunes. The agreement between the PIV and LDV is good enough even in regions of flow reversals and high shear. Though limited in the wall normal direction field-of-view, PIV provides instantaneous flow fields, which reveal the complex nature of flow over dunes, as well as more sophisticated analyses such as two-point space correlation and quadrant analysis with a reasonable accuracy.

  • PDF

MODELING AND OPTIMIZATION Of A FIXED-BED CATALYTIC REACTOR FOR PARTIAL OXIDATION OF PROPYLENE TO ACROLEIN

  • Lee, Ho-Woo;Ha, Kyoung-Su;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.451-451
    • /
    • 2000
  • This study aims for the optimization of process conditions in a fixed-bed catalytic reactor system with a circulating molten salt bath, in which partial oxidation of propylene to acrolein takes place. Two-dimensional pseudo-homogeneous model is adopted with estimation of suitable parameters and its validity is corroborated by comparing simulation result with experimental data. The temperature of the molten salt and the feed composition are found to exercise significant influence on the yield of acrolein and the magnitude of hot spot. The temperature of the molten salt is usually kept constant. This study, however, suggests that the temperature of the molten salt must be axially adjusted so that the abrupt peak of hot spot should not appear near the reactor entrance. The yield of acrolein is maximized and the position and the magnitude of hot spot are optimized by the method of the iterative dynamic programming (IDP).

  • PDF

Prediction of the Dynamic Adsorption Behaviors of Uranium and Cobalt in a Fixed Bed by Surface Modified Activated Carbon

  • Park, Geun-Il;Lee, Jung-Won;Song, Kee-Chan;Kim, In-Tae;Kim, Kwang-Wook;Yang, Myung-Seung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.73-77
    • /
    • 2003
  • In order to predict the dynamic behaviors of uranium and cobalt in a fixed bed at various influent pH values of liquid waste, the adsorption system was regarded as multi-component adsorption between each ionic species in a solution. Langmuir isotherm parameters of each species were extracted by incorporating equilibrium data with the solution chemistry of uranium and cobalt using IAST. Prediction results were in good agreement with the experimental data, except for a high concentration and pH. Although there was some limitations in predicting the cobalt adsorption, this method may be useful in analyzing a complex adsorption system where various kinds of ionic species exist in a solution.

  • PDF

The Effect of Porosity of Seiving Particles on the Romoval Efficiency of Organic Substances via Biofilter in the Fixed Bed

  • Park Young Gyu
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • This paper was investigated to clarify the possibility of a biodegradation of materials adsorbed on different porous granular-activated carbons (GACs) such as coal-& coconut-based GAC. Total organic carbon, humic substance and ammonia were used to compare their removal efficiencies. The objective of this study is to determine the adsorption capacity of bioregenerated GAC. When raw water reacted with chloride, the yield of THMs increased as a function of the input amount of chloride. The formation of trihalomethanes (THMs) was investigated in water treated with chlorine when humic acid was used as THM precursor. As the input amount of chloride in raw water increased by two or five-fold to remove the $NH_3$, the chloroform of the THMs significantly increased also five or ten-fold. It was found that the chloroform was significantly removed by the treatment of biological activated carbon (BAG) in comparison with the ozone treatment, and the removal efficiency of THMs in coal-typed GAC was $10-30\%$ better than coconut-typed GAC due to the biological degradation on the surface of the activated carbons.

Identification of guideway errors in the end milling machine using geometric adaptive control algorithm (기하학적 적응제어에 의한 엔드밀링머시인의 안내면 오차 규명)

  • 정성종;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.163-172
    • /
    • 1988
  • An off-line Geometric Adaptive Control Scheme is applied to the milling machine to identify its guideway errors. In the milling process, the workpiece fixed on the bed travels along the guideway while the tool and spindle system is fixed onto the machine. The scheme is based on the exponential smoothing of post-process measurements of relative machining errors due to the tool, workpiece and bed deflections. The guideway error identification system consists of a gap sensor, a, not necessarily accurate, straightedge, and the numerical control unit. Without a priori knowledge of the variations of the cutting parameters, the time-varying parameters are also estimated by an exponentially weighted recursive least squares method. Experimental results show that the guideway error is well identified within the range of RMS values of geometric error changes between machining passes disregarding the machining conditions.

Fixed bed column modeling of lead(II) and cadmium(II) ions biosorption on sugarcane bagasse

  • Vera, Luisa Mayra;Bermejo, Daniel;Uguna, Maria Fernanda;Garcia, Nancy;Flores, Marittza;Gonzalez, Enrique
    • Environmental Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • In this paper the results of the biosorption of lead(II) and cadmium(II) with sugarcane bagasse in fixed bed columns are presented. Experimental data were fitted to several models describing the rupture curve for single-component and two-component systems. The percentages of removal of lead and cadmium in single-component systems are 91% and 90%, respectively. In lead-cadmium bicomponent systems the percentage of elimination of lead was 90% and cadmium 92%. In single-component systems, Yoon-Nelson and Thomas models successfully reproduce the rupture curves. In two-component system, the Dose-Response model was the best one reproducing the experimental rupture curves in the entire measured range.

Effect of Additional Gaseous Fuel in Iron Ore Sinter Process (제철 소결 공정에서 추가 가스 연료 주입에 따른 영향)

  • Lee, Younghun;Choi, Sangmin;Yang, Won;Cho, Byungkook
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.21-24
    • /
    • 2012
  • In the iron ore sinter process, temperature distribution pattern in sintering bed is related with productivity and quality of sintered ore. Evenly heat distribution make the uniform quality of sintered ore but in normal operating condition, upper part of bed has lack of heat and scarce quality of sintered ore, thus yeild rate is decreased and productivity is diminished. Therefore, using the additional fuel in the upper part of bed is considered and effect of fuel is discussed. (max. 80 words).

  • PDF