• 제목/요약/키워드: Fitting evaluation

검색결과 309건 처리시간 0.029초

일개 의료원 산하 병원간 전략과 HR시스템의 정합성 평가 (Evaluation on Fitness between Human Resource Management System and Strategy on Subsidiary Hospitals of Medical Center)

  • 김영훈;김한성;우정식;김효정
    • 한국병원경영학회지
    • /
    • 제17권1호
    • /
    • pp.59-78
    • /
    • 2012
  • The purpose of this study is to evaluate on the fitting with human resource practice and strategic on 6 public hospital in the point of resource based view. At the result of this study, public strategy is not much fitted into HRM(human resource management) system, but it shows positive result of the fitting with efficiency strategy and HRM system. These results were associated with the integration of G Medical Center. Generally 6 public hospitals of the HRM system and the strategy had not been linked. They also did not achieve a great outcome. We suggest that the manager in charge of each hospital make strategies of the hospital, and then evaluates about fitting with HRM system. We hope, hereafter, it applied the analysis methods that evaluates it with financing result and individual non-financial result all together.

  • PDF

인체의 동작을 고려한 스케이트 팬츠 패턴 개발 (Pattern Development of Skate Pants Allowing for Dynamic Movement and Postures)

  • 정연희
    • 한국생활과학회지
    • /
    • 제17권1호
    • /
    • pp.115-126
    • /
    • 2008
  • The construction of an athlete's tight-fitting garments is very important to the wearer in terms of athletic performance. Therefore pattern development of tight-fitting garments must allow for the full range of human movement and postures. In this study the relationship between the construction of a skate pants pattern and clothing fitting was explored with the aim of improving the comfort of the clothing. The four male subjects were university students between the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using a seven-point Likert scale on four consecutive days. While wearing the garments, subjects were asked to take five different postures including waist flexion, sitting and others. A Likert-type scale was used for the evaluation, with 7 points indicating the best fit in tight-fitting pants. Results showed differences in the front-rise length and back-rise length between basic pants(A) and modified pants(B,C,D) were -5.16cm and +5.64cm. Comparing the basic pants pattern(A) with modified pants pattern(B), the latter was superior to basic pants(A) in terms of pressure sensation and closeness of fit, but there was no significant difference. Among the four tight-fitting skate pants, A and B pants were superior to the others in terms of fitting and stability of waist and hip sections. In the case of the skate pants, the number of cutting lines in the pattern had an influence on clothing comfort. A minimum cutting line for tight skate pants was better than a maximum cutting line in terms of clothing comfort.

휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발 (Development of Tight-Fitting Garments with a Portable ECG Monitor to Measure Vital Signs)

  • 정연희;김승환;양영모
    • 한국의류학회지
    • /
    • 제34권1호
    • /
    • pp.112-125
    • /
    • 2010
  • A Holter monitor is used for ECG monitoring of ambulatory daily life in hospital. However, the use of this apparatus causes skin allergies and discomfort in patients because of the attachment gel and tapes used to attach disposable electrodes to the skin. In this study, the development of tight-fitting clothing connected to a portable Holter monitor was proposed. In addition, the use of conductive fabrics as electrodes was proposed; this will enable the use of garments in u-health care for measuring ECG signals. The male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales. A Likert type scale was used for the evaluation and a 7 point score indicates that it provided the best fit as a tight-fitting upper clothing. Clothing pressure was measured using an air-pack-type pressure sensor (model AMI 3037-2) at 4 locations (the conductive fabric electrode) As results, a male basic sloper for upper clothing was developed and that pattern was manipulated to the tight fit pattern by considering the reduction rate of the percentage stretch in the fabric. The developed tight-fitting garment was superior in terms of subjective sensation and 6t. The mean pressure of the garment with reduction rates of 40% in width and of 50% in length was 8.45gf/$cm^2$. A conductive fabric electrode was developed by considering the sewing method and the developed electrode was detected well. The ECG data were recorded for 13 hr 19 min 44 sec and the artifacts in the ECG signals were recorded for 9 hr 3 min 46 sec (total time: 22 hr 23 min 23 sec). The artifacts data were obtained during heavy activities.

확률 분포 함수의 지수 곡선 접합을 이용한 RVE 적합성 평가 (Evaluation of RVE Suitability Based on Exponential Curve Fitting of a Probability Distribution Function)

  • 정상엽;윤태섭;한동석
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.425-431
    • /
    • 2010
  • 2가지 이상의 재료로 구성된 다상(multi-phase) 재료는 상 분포에 따라 재료 특성이 다르기 때문에, 상 분포를 묘사할 수 있는 적절한 방법이 필요하다. 본 연구에서는 확률 분포 함수 two-point correlation function과 lineal-path function을 사용하여 재료 내부의 상 분포 상태를 확률적으로 묘사하였다. 수치 계산 방법으로 계산되는 확률 분포 함수를 3개의 매개 변수를 사용한 곡선 접합(curve fitting)을 이용하여 수식으로 표현하고, 적용성을 살펴보기 위하여 2상 합금 미세구조 가상 시편과 지반 모델 시편을 사용하였다. 이를 통해, 확률 분포 함수는 곡선 접합을 이용하여 지수 형태의 수식으로 표현이 가능하며, 이는 시편의 RVE로서의 활용 가능성을 판단하는데 사용될 수 있음을 확인하였다.

단신 : 페달링 시 정량적인 동적 피팅을 위한 실시간 평가 시스템 (Technical-note : Real-time Evaluation System for Quantitative Dynamic Fitting during Pedaling)

  • 이주학;강동원;배재혁;신윤호;최진승;탁계래
    • 한국운동역학회지
    • /
    • 제24권2호
    • /
    • pp.181-187
    • /
    • 2014
  • In this study, a real-time evaluation system for quantitative dynamic fitting during pedaling was developed. The system is consisted of LED markers, a digital camera connected to a computer and a marker detecting program. LED markers are attached to hip, knee, ankle joint and fifth metatarsal in the sagittal plane. Playstation3 eye which is selected as a main digital camera in this paper has many merits for using motion capture, such as high FPS (Frame per second) about 180FPS, $320{\times}240$ resolution, and low-cost with easy to use. The maker detecting program was made by using Labview2010 with Vision builder. The program was made up of three parts, image acquisition & processing, marker detection & joint angle calculation, and output section. The digital camera's image was acquired in 95FPS, and the program was set-up to measure the lower-joint angle in real-time, providing the user as a graph, and allowing to save it as a test file. The system was verified by pedalling at three saddle heights (knee angle: 25, 35, $45^{\circ}$) and three cadences (30, 60, 90 rpm) at each saddle heights by using Holmes method, a method of measuring lower limbs angle, to determine the saddle height. The result has shown low average error and strong correlation of the system, respectively, $1.18{\pm}0.44^{\circ}$, $0.99{\pm}0.01^{\circ}$. There was little error due to the changes in the saddle height but absolute error occurred by cadence. Considering the average error is approximately $1^{\circ}$, it is a suitable system for quantitative dynamic fitting evaluation. It is necessary to decrease error by using two digital camera with frontal and sagittal plane in future study.

Evaluation of energy correction algorithm for signals of PET in heavy-ion cancer therapy device

  • Niu, Xiaoyang;Yan, Junwei;Wang, Xiaohui;Yang, Haibo;Ke, Lingyun;Chen, Jinda;Du, Chengming;Zhang, Xiuling;Zhao, Chengxin;Kong, Jie;Su, Hong
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.101-108
    • /
    • 2020
  • In order to solve the contradiction between requirements of high sampling rate for acquiring accurate energy information of pulses and large amount of data to be processed timely, the method with an algorithm to correct errors caused by reducing the sampling rate is normally used in front-end read-out system, which is conductive to extract accurate energy information from digitized waveform of pulse. The functions and effects of algorithms, which mainly include polynomial fitting with different fitting times, double exponential function fitting under different sampling modes, and integral area algorithm, are analyzed and evaluated, and some meaningful results is presented in this paper. The algorithm described in the paper has been used preliminarily in a prototype system of Positron Emission Tomography (PET) for heavy-ion cancer therapy facility.

착용쾌적성이 향상된 방탄복 개발과 성능평가 (Development and Performance Evaluation of Body Armor for Wear Comfort Enhancement)

  • 김소영;이예진;홍경희
    • 한국의류학회지
    • /
    • 제36권10호
    • /
    • pp.1050-1057
    • /
    • 2012
  • This study helps develop a cool body armor that maintains a tight-fit configuration to the body surface and evaluates the performance of newly developed body armor in a wear test. Three types of body armor were used for evaluation. One was a tight fitting body armor that was constructed to improve the degree of fit and ease of movement for Korean soldier using 3D technology. Another was ventilating body armor with attached spacers on the shoulder to reduce the thermal stress on the soldier. The third was a prevailing body armor produced by a Korean body armor company. In order to evaluate the performance of the body armor, a human wear test, a thermal mannequin test, and computational fluid dynamics (CFD) were executed. Five subjects participated in the wear test. Subjective wear sensation, total amount of sweat and dynamic change of clothing microclimate were observed during and after exercise on a treadmill; subsequently, it was found that subjects rated tight fitting body armor and ventilating body armor lighter, drier, and easier to move than the conventional body armor (p<.05). Total amount of sweat was the least in the case of ventilating body armor. The thermal resistance and vapor resistance of the ventilating body armor were improved remarkably. In addition, the skin temperature of the ventilating body armor with spacers was lower than the tight fitting body armor by at least $1^{\circ}C$ in the CFD result. It is noted that thermal-wet comfort of the 3D body armor with ventilating feature is superior to the conventional body armor, especially when the ventilating channel is not closed due to a backpack.

자전거 페달링 시 하지 정렬 평가를 위한 영상 시스템 개발 (Simple Camera-based Evaluation System for Lower Limb Alignment during Pedalling)

  • 오호상;최진승;강동원;서정우;배재혁;탁계래
    • 한국운동역학회지
    • /
    • 제22권1호
    • /
    • pp.123-129
    • /
    • 2012
  • Simple camera-based system for evaluation of lower limb alignment as a part of an automated cycling fitting system was developed and verified in this study. Developed imaging system can evaluate lower limb alignment quantitatively during pedaling using a general camcorder and single marker attached on the knee. Threshold-based marker detection algorithm was proposed in this study. Experiment was carried out to compare the trajectory data from marker detection algorithm of the developed imaging system with the trajectory data from 3-D motion capture system. Results showed that average error between trajectories was 2.33 mm (0.92 %) in the vertical direction and 0.62 mm (1.86 %) in the medio-lateral direction. There existed significant correlation between two measured values (r=0.9996 in the vertical direction and r=0.9975 in the medio-lateral direction). It can be concluded that developed imaging system be applied to evaluate lower limb alignment which is an important factor for dynamic bicycle fitting.

3D 가상착의를 활용한 40~50대 비만남성 피티드 토르소 패턴 개발 ( Developing a fitted torso pattern for obese males in their forties and fifties utilizing virtual fitting)

  • 장정아;권의정
    • 복식문화연구
    • /
    • 제30권6호
    • /
    • pp.828-841
    • /
    • 2022
  • This study aims to develop a fitted torso pattern suitable for males in their forties and fifties who are obese-a group that accounts for more than fifty percent of men in this age group-using a 3D virtual fitting program. Size Korea's 2022 data for obese males in their forties and fifties is utilized for this study. In terms of the research method, a 3D program (CLO 3D) is used to implement the target group's various body types and to apply fitted torsos that enable verification and evaluation of the pattern's fit and ease. The characteristics of fitted torso patterns for obese bodies are as follows: the front centerline is a profile line; shoulder darts are added by reflecting waist-abdominal protrusion in the front panel; and shoulder, arm, waist, and center-back darts are constructed for the back panel. For obese bodies, the minimum circumference ease amounts should be approximately 6-7cm for the chest, 6cm for the waist, and 6-7cm for the hips. Based on an evaluation of the virtual fit of the developed fitted torso pattern, the data shows that a pattern (foundation) such as this is well suited for obese body types with an average of 4.67/5 points for reverse triangular obesity, an average of 6.67/7 points for log obesity, and an average of 6.69 points for the ease amount.