• Title/Summary/Keyword: Fistula formation

Search Result 100, Processing Time 0.022 seconds

Management of Pharyngocutaneous Fistula Following Laryngectomy (후두적출술 후 발생한 인두피부누공의 치료 경험)

  • Min Hun-Ki;Kwon Soon-Young;Jung Kwang-Yoon;Choi Jong-Ouck
    • Korean Journal of Head & Neck Oncology
    • /
    • v.11 no.2
    • /
    • pp.167-172
    • /
    • 1995
  • Pharyngocutaneous fistula(PCF) is one of the complications following total laryngectomy in laryngeal and hypopharyngeal cancer. Fistula lead to delayed wound healing, more serious complications such as carotid blow-out, prolonged hospitalization, significant patient morbidity and occasional mortality. Identification of patients at high risk for fistula formation, appropriate preventive measures, and appropriate management are the head and neck surgeon's responsibility. So we analyzed the clinical data of pharyngocutaneous fistula which was developed after total laryngectomy. Following results were obtained: 1) Occurrence of PCF increases with salvage surgery compared to curative surgery. 2) Early detection and effective management of PCF are the key factors to decreasing the hospitalization period. 3) Constructing a pharyngostoma seems to be an ideal method of preventing dangerous complications and ultimately closing the fistula. 4) Simultaneous reconstruction is necessary in the high risk group.

  • PDF

Surgical Outcomes of Forearm Loop Arteriovenous Fistula Formation Using Tapered versus Non-Tapered Polytetrafluoroethylene Grafts

  • Han, Sun;Seo, Pil Won;Ryu, Jae-Wook
    • Journal of Chest Surgery
    • /
    • v.50 no.1
    • /
    • pp.30-35
    • /
    • 2017
  • Background: Tapered grafts, which have a smaller diameter on the arterial side, have been increasingly used for arteriovenous fistula (AVF) formation. We compared the outcomes of 4-6-mm tapered and 6-mm straight forearm loop arteriovenous grafts. Methods: A total of 103 patients receiving forearm loop arteriovenous grafts between March 2005 and March 2015 were retrospectively analyzed and separated into 2 groups (group A, 4- to 6-mm tapered grafts, n=78; group B, 6-mm straight grafts, n=25). In each group, complications and patency rates after surgery were assessed. Results: Clinical characteristics and laboratory results, except for cerebrovascular disease history (group A, 7.7%; group B, 28.0%; p=0.014), were similar between the groups. No significant differences were found for individual complications. Kaplan-Meier survival analysis revealed no significant differences in 1-year, 3-year, and 5-year patency rates between groups (61.8%, 44.9%, and 38.5% vs. 62.7%, 41.1%, and 35.3%, respectively). Conclusion: We found no significant differences in complication and patency rates between the tapered and straight graft groups. If there are no differences in complication and patency between the two graft types, tapered grafts may be a valuable option for AVF formation in light of their other advantages.

Factors Influencing on Early Patency Rate of Autogenous Arteriovenous Fistula for Hemodialysis (혈액투석을 위한 자가 동정맥루 수술에 있어서 조기개존율에 영향을 미치는 요인)

  • 민선경;한재진;원태희;안재호
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.342-348
    • /
    • 2004
  • It is very important for hemodialysis in patients with end stage renal disease to obtain vascular access that resists repeated punctures and maintains adequate blood flow. This study was designed to indentify factors that may influence early patency rate of autogenous arteriovenous fistula. Material and Method: 49 cases in 47 patients who underwent radiocephalic fistula formation in our hospital from June 2002 through May 2003 were reviewed and analyzed. Result: The early patency rate was 79.6%. Age, sex, hypertension, and diabetes mellitus were not significant factors for patency. Body mass index and duration of hypertension and diabetes did not influence the early results either. Cephalic vein diameter measured preoperatively and blood flow at radio-cephalic fistula were significantly positive correlative factors. Groups with the vein diameter less than 2.7mm, or with the blood flow less than 100 mL/min had significantly lower early patency rate than the other groups. Conclusion: To improve early patency rate of radiocephalic fistula, large sized cephalic vein should be selected and if the intraoperative flow at radiocephalic fistula is less than 100 mL/min, another arteriovenous fistula formation should be considered.

Non-Surgical Management of Gastroduodenal Fistula Caused by Ingested Neodymium Magnets

  • Phen, Claudia;Wilsey, Alexander;Swan, Emily;Falconer, Victoria;Summers, Lisa;Wilsey, Michael
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.4
    • /
    • pp.336-340
    • /
    • 2018
  • Foreign body ingestions pose a significant health risk in children. Neodymium magnets are high-powered, rare-earth magnets that is a serious issue in the pediatric population due to their strong magnetic force and high rate of complications. When multiple magnets are ingested, there is potential for morbidity and mortality, including gastrointestinal fistula formation, obstruction, bleeding, perforation, and death. Many cases require surgical intervention for removal of the magnets and management of subsequent complications. However, we report a case of multiple magnet ingestion in a 19-month-old child complicated by gastroduodenal fistula that was successfully treated by endoscopic removal and supportive care avoiding the need for surgical intervention. At two-week follow-up, the child was asymptomatic and upper gastrointestinal series obtained six months later demonstrated resolution of the fistula.

Congeniral Coronary Arteriovenous Fistula; Right Coronary- Right Ventricle; Report of Two Cases (우관상동맥에서 우심실로 개구되는 선천성 관동맥루;수술치험 2례)

  • 윤영철
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.638-642
    • /
    • 1993
  • Congenital coronary arteriovenous fistula is relatively uncommon and widespread use of echocardiogram and selective coronary angiogram are being recognized with increasing frequency. The right coronary artery is most commonly involved and the fistulous communication is most common to right ventricle. Surgical correction is strongly recommended to prevent the development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and pulmonary hypertension, as well as coronary aneurysm formation, with subsequent rupture or embolism. We report two cases of coronary arteriovenous fistula originated from right coronary artery terminated in the right ventricle. These 8 year-old female and 7 year-old male patients had surgical interventions using cardiopulmonary bypasses.

  • PDF

Surgery for Synovial Fistula after Excision of the Lateral Malleolar Bursitis of the Ankle: A Case Report (족관절 외과의 점액낭염 절제술 후 발생한 활액막 누공의 수술적 치료: 증례 보고)

  • Jang, Hyo-Seok;Choi, Hong-Joon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.3
    • /
    • pp.118-121
    • /
    • 2015
  • Lateral malleolar bursitis of the ankle is a commonly encountered disease in the department of orthopedic surgery. Although most cases of lateral malleolar bursitis are managed by conservative treatments, operative treatment is considered in cases of infected bursitis or complication after surgery. There are several potential complications associated with operative treatment, including wound healing problem, skin necrosis, nerve injury, or recurrence. However, synovial fistula of the ankle as a complication after surgery for lateral malleolar bursitis has not been previously reported. The author experienced the complication of synovial fistula after surgery for lateral malleolar bursitis and obtained a satisfactory result in revision surgery for the complication, which was coverage of the fistular formation with a periosteal flap from the distal fibula.

Spontaneous Regression of the Pseudoaneurysm Developed after Balloon Occlusion of the Direct Carotid-cavernous Fistula

  • Lee, Chae-Heuck;Kim, Myoung-Soo;Lee, Ghi-Jai
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.323-326
    • /
    • 2007
  • Direct carotid-cavernous fistula [CCF] is a common post-traumatic disease. However, pseudoaneurysm formation after balloon occlusion is a rare complication. The author present such a case with review of the literature. A 26-year-old man involved in a motor vehicle accident as a driver. Only mild conjunctival injection and minimal exophthalmos on the right eye were noted after trauma. However, angiography revealed a direct CCF and dissection of the proximal intracranial internal carotid artery [ICA]. After first balloon occlusion of the CCF, the patient redeveloped fistula due to early deflation of the balloon. After the second balloon occlusion, pseudoaneurysm and diplopia were developed with the change of balloon position and shape. However, visual symptom spontaneously resolved and pseudoaneurysm was also decreased within 6 months after balloon occlusion.

Radial Arteriovenous Fistula Developed Late after Coronary Angiography: A Case Report

  • Na, Kwon Joong;Kim, Myung A;Moon, Hyeon Jong;Lee, Jeong Sang;Choi, Jae-Sung
    • Journal of Chest Surgery
    • /
    • v.45 no.6
    • /
    • pp.421-423
    • /
    • 2012
  • Transradial access is a widely accepted method for percutaneous coronary diagnostic and interventional procedures, and it has dramatically reduced access site vascular complications compared to transfemoral access. Arteriovenous fistula formation at the access site is an especially rare complication in transradial access. We report an extremely rare case of delayed radial arteriovenous fistula that developed one year after transradial coronary angiography, which was successfully treated by surgical repair.

Multiple foreign bodies causing an orocutaneous fistula of the cheek

  • Kim, Woo Ju;Kim, Woo Seob;Kim, Han Koo;Bae, Tae Hui
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.2
    • /
    • pp.139-142
    • /
    • 2018
  • Foreign bodies impacted in the maxillofacial region are often a diagnostic challenge. They can be a source of chronic inflammatory reactions and infections leading to the formation of an orocutaneous fistula. Such orocutaneous fistulas cause significant morbidity in most patients, eventually requiring surgery. Recently, we encountered a very rare case of an orocutaneous fistula caused by multiple foreign bodies in the cheek. Precise removal of the foreign bodies was required, and a double-sided anterolateral thigh free flap was used to reconstruct the defect. Surgeons should be aware of the complications of multiple foreign bodies and should be able to diagnose these on careful clinical examination.

Multiple Pulmonary Arteriovenous Fistula combined with Cyanosis Report of one Case (청색증을 동반한 다발성 폐동정맥루 치험 1례)

  • 조규도
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.806-811
    • /
    • 1985
  • Pulmonary arteriovenous fistula is a rare congenital vascular malformation in the lung, resulting from erroneous capillary development, with incomplete formation or disintegration of the vascular septa that would normally divide the primitive connection between the venous and arterial plexus. The pathogenesis of its symptom is that unoxygenated and desaturated arterial blood enter into the pulmonary venous system directly. Recently we have experienced a case of multiple pulmonary arteriovenous fistula in a 15 year old male patient, who presented the symptom of cyanosis and dyspnea on exertion. The operation revealed well circumscribed and multilobulated aneurysmal lesion in left lower lobe with its subpleural and posterolateral basal location, and another aneurysmal lesion in inferior lingular segment of left lung. There was no abnormal connection between the fistula and systemic circulation. The left lower lobectomy was performed along with local extirpation of the inferior lingular segment of left lung. Both lesions showed angiomatous dilatation of the various sized vessels embedded in the parenchyma microscopically. Postoperative clinical course disclosed much improvement in symptoms and in the value of blood gas analysis. The patient was discharged without any complication.

  • PDF