• Title/Summary/Keyword: Fire-retardant performance

Search Result 88, Processing Time 0.024 seconds

A Study on Fire Prevention Capability Performance Evaluation of the Phosphate Flame Retardant Honeycomb Core (인계 난연 허니컴 코아의 방화성능평가에 관한 연구)

  • Moon, Sung-Woong;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.72-77
    • /
    • 2010
  • Honeycomb core structure with its excellent stiffness and strength is being utilized in many fields such as interior building material. Because it is inexpensive and renewable, honeycomb paper production is economically and environmentally helpful. However, the paper needs to be fireproofed because it is vulnerable to fire. In this study, we have undergone the performance evaluation process of the honeycomb paper which is widely used as interior material of a fire door and packing material. Four kinds of honeycomb (a honeycomb made of flame-resistant paper; a honeycomb attached with conventional flame-resistant film made in the laboratory; honeycomb impregnated with flame retardant; a honeycomb attached with flame-resistant film after impregnating fire retardant) were used in the study to compare the fire retardant performance. As a result, the honeycomb with impregnated flame retardant showed the highest performance. The flame-resistant film was effective in delaying the igniting time but had a negative effect on the rate of heat and smoke production.

A Study on the fire characteristic of pipe insulation film materials (배관 보온필름의 화재특성에 관한 연구)

  • Lee, Young-Sam;Lee, Jang-Won;Rie, Dong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • This study was performed to test the combustive properties of the pipe insulation materials which are mainly used in the industries and buildings. Fire characteristic test of pipe insulation film according to the KS F ISO 5660-1 was performed. The experimental materials commonly used in the pipe insulation were used four kinds of films. Two kinds of 4 types of products that have the flame retardant performance and the other two types of them have no flame retardant performance. They were selected for fire characteristic test. The result of finding 25kW/$m^2$ radiation from the ignition was that flame retardant products were 140sec and the other one were 69sec in average of heat release rate(HRR). The result of flame retardant products in the 50kW/$m^2$ was 34sec and the other one were 15sec in average of HRR. However, the HRR of flame retardant products was much higher than the other one. Flame propagation test was conducted according to the KOFEIS 1001. The result of flame retardant products was that flame retardant products had a hold without fire spread after firing them. But the other one were completely fired after firing them. Therefore, I want to recommend that flame retardant products need to be used by the regulation to prevent or decrease a fire spread.

A Study on the Smoke Hazard Increase of Flame-retardant-treated Interior Decorative Textile -Focused on Viscose Rayon Textile Wallcovering- (난연 처리된 실내장식섬유의 연기 위해성 증가에 관한 연구 -비스코스 레이온 섬유 벽지를 중심으로-)

  • Lee, Joonhan;Kim, Sun Mee
    • Journal of Fashion Business
    • /
    • v.24 no.3
    • /
    • pp.30-39
    • /
    • 2020
  • This study was conducted to identify problems in domestic flame-retardant performance specifications. Currently, the domestic wallcovering anti-inflammatory regulations are not prepared for damage caused by smoke, with the carbonized area as the main function. In particular, given that smoke is the main cause of human casualties and injuries in a fire, it is reasonable that the flame density and toxicity of the wallcovering should also be the main performance indicators. The scope and method of research in this study were as follows. First, a prior study related to fire on various wallcoverings was considered. Second, it raised questions about the effects of smoke in the event of a fire and domestic anti-inflammatory performance tests. Third, textile wallcovering samples were manufactured with viscose rayon for experimental verification of the problems and tested by Korean and EU standards without flame retardant processing to analyze the differences between each regulation. Fourth, the performance of flame retardant wallcovering according to Korean standards was evaluated using smoke density and harmful gas testing methods. The results of each test were as follows. Non-fire retardant wallcovering was rejected by Korea standards. However, B-s1.d0 in Europe. Smoke density testing and harmful gas by domestic combustion processing on the same sample showed that the smoke density increased about 4.3 times more than before, and the harmful gas test showed that the suspension of the post-processing sample slowed earlier than the non-processed sample.

Study on Property Change with a Fire Retardant Content in the Manufacture of Polymer Composites for Cable Sheath

  • Li, Xiang Xu;Lee, Sang Bong;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • v.54 no.2
    • /
    • pp.118-122
    • /
    • 2019
  • Four different polymer compounds were manufactured to make cable sheaths for the shipping industry. Two kinds of ethylene vinyl acetate (EVA) as the main matrix polymers and EVA-grafted maleic anhydride (EVA-g-MAH) as the coupling agent were selected for compounding with fire retardant, crosslinking agent, filler, plasticizer, and other additives. The properties of the four compounded materials were investigated with different contents of the fire retardant, silanecoated magnesium dihydroxide (S-MDH). In the rheology evaluation, the $t_{60}$ and ${\Delta}T$ values increased with increasing S-MDH contents. On the other hand, the tensile strength decreased with increasing S-MDH content due to a relative decrease in binder polymers. With increasing S-MDH content, fire resistance increased, but cold resistance showed no obvious enhancement due to the polar effect of vinyl acetate in EVA.

Fire Performance of the Wood Treated with Inorganic Fire Retardants

  • Son, Dong-Won;Kang, Mee-Ran;Kim, Jong-In;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.335-342
    • /
    • 2012
  • To prepare the eco-friendly fire retardant wood, Japanese red pine (Pinus densiflora), Hemlock (Tsuga heterophylla), and Radiata pine (Pinus radiata) were treated with inorganic chemicals, such as sodium silicate, boric acid, ammonium phosphate, and ammonium borate. Different combination and concentration of those chemicals were impregnated by vacuum/pressure treatment methods. The electron-beam treatment was used to increase the chemical penetration into the wood. The fire performance of the fire retardant treated wood was investigated. The penetration of chemicals into the wood was enhanced after electron beam treatment. Ignition time of the treated wood was the most effectively retarded by sodium silicate, ammonium phosphate, and ammonium borate. The most effective chemical combination was found at 50% sodium silicate and 3% ammonium borate, which satisfied flammability criteria for a fire retardant material in the KS F ISO 5660-1 standards.

A Study for the Fire Retardant-Characteristics of Expandable Graphite Composite Materials (팽창흑연을 사용한 복합재료의 난연 특성에 관한 연구)

  • Chun, Kwan-Ok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.28-33
    • /
    • 2017
  • In this study, the composite material of expandable graphite was made to the material development for improving such as a composite material of the sandwich panels or material properties of a fire door and was tested by the ISO 1182, ISO 5660-1(Cone calorimeter Method). For the test, the composite material of expandable graphite, what the expandable graphite ratio was increased by respectively 0g~30g, was classified A1,A2, A3, A4, and made to the test specimens. Through cone calorimeter test, peak heat release rate(HRR) and total heat release(THR), expanded thickness and expansion rate of each composite material of expandable graphite, and fire prone crack and mass loss rate after burning was measured. Thus, the effect of the addition of the expandable graphite and whether is suitable for reference as a fire retardant, was analyzed. Consequently the correlation of THR and fire retardant performance rate was confirmed.

Comparison on the fire performance of additional insulation materials for improving the fire retardancy in engine-room of FRP vessel (FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교)

  • Choi, Jung-Min;Um, Han-Chan;Jin, Young-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1150-1155
    • /
    • 2014
  • To prevent the flame spread in FRP vessel in fire, the engine-room of the vessel should be constructed additionally with laminated fire-retardant resin over 3 times or equivalent insulation materials to former according to the relevant standard for FRP vessel structure. It is surveyed that insulation materials called 'Gel coat' are widely used in FRP fishing vessel, however, test method and its criteria for Gel coat are not clearly establish and have not been evaluated yet, while test method and criteria for fire-retardant resin and fire-retardant polyurethane composite are described in test standard for type-approval. In this study, 3 fire-retardant resins, 4 gel coats, 1 flame-retardant paint and 1 polyurethane composite were selected based on the survey and were evaluated according to both IMO FTP Code part 5 and flame-retardant test. When comparing based on CFE values from flame-spread test, average value for 4 gel coats were lower than that of 3 fire-retardant resins. As for flame-retardant test, there were no significant differences between fire-retardant resin and gel coat, based on charred area.

Study on the Smoke Density Characteristics of Flame Retardant Sol Manufactured by a Sol-gel Method (졸-겔법으로 제조된 방염제졸의 연기밀도 특성에 관한 연구)

  • Cho, Kyeong-Rae;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.11-18
    • /
    • 2017
  • In this study, a non-halogen type organic-inorganic hybrid flame retardant sol, which can impart flame resistance to synthesize silicate of inorganic material and silane coupling agent of organic material by a sol-gel method, were newly manufactured. The addition of flame retardant will prevent loss of life in a fire because smoke from the flammability of interior finishing materials used as the construction materials poses a major danger. The smoke density measurement standard based on flame retardant performance standards, experiments were conducted according to the test equipment and procedures of ASTM E 662. The non-flaming mode experiment and the flaming mode experiment were conducted to confirm the performance of the manufactured flame retardant sol. As a result, the manufactured flame retardant sol improved the physical properties and heat resistance of existing flame retardants, and decreased the smoke production of the fire. Therefore, it may be possible to reduce the damage caused by smoke and expand the applications to various interior finishing materials.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

A Study on Evaluation Methods for the Fire-retardant Performance of Hanok Components (건축 마감재의 화재안전기준 비교분석을 통한 한옥 부재의 난연성능 평가기준 연구)

  • Kwark, Ji-Hyun;Choi, Jung-Min;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2011
  • In this study, standards and test methods for building materials of domestic and foreign countries were compared and analyzed to propose evaluation methods for the fire-retardant performance of HANOK components (Traditional house). IBC and NFPA codes recently have been adopted in the US, and the properties such as critical heat flux, fire spread index and smoke density are being used as an evaluation reference. In Europe, the unified Euroclass has been adopted and the surface flammability, prototype fire test or cone calorimeter test are conducted for the performance test. Japan has the similar system as Korea where the class is classified into 3 grades. We tried to study a quantitative evaluation method of fire retardant performance for the HANOK components based on the analysis results of the several countries' standards and test methods for building materials.