• Title/Summary/Keyword: Fire-retardant

Search Result 264, Processing Time 0.026 seconds

A Study on Evaluation Methods for the Fire-retardant Performance of Hanok Components (건축 마감재의 화재안전기준 비교분석을 통한 한옥 부재의 난연성능 평가기준 연구)

  • Kwark, Ji-Hyun;Choi, Jung-Min;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2011
  • In this study, standards and test methods for building materials of domestic and foreign countries were compared and analyzed to propose evaluation methods for the fire-retardant performance of HANOK components (Traditional house). IBC and NFPA codes recently have been adopted in the US, and the properties such as critical heat flux, fire spread index and smoke density are being used as an evaluation reference. In Europe, the unified Euroclass has been adopted and the surface flammability, prototype fire test or cone calorimeter test are conducted for the performance test. Japan has the similar system as Korea where the class is classified into 3 grades. We tried to study a quantitative evaluation method of fire retardant performance for the HANOK components based on the analysis results of the several countries' standards and test methods for building materials.

Incombustibility of Polypropylene by Metal Addition Flame Retardant (폴리프로필렌의 금속첨가형 난연제에 의한 난연 특성)

  • Lee, Sang-Eun;Song, Young-Ho;Chung, Kook-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.40-45
    • /
    • 2005
  • The principal actions of a flame retardant are to decrease or prevent the formation of volatile products and increase the formation of char layer. Use of flame retardant additives can decrease the overall fire hazard of the product containing them thus leading to an increase in overall fire safety. Although several flame retardants have been developed for use in polymers, many of these are known to increase the amount of smoke and toxic gases generated by them. This paper present a new flame retardant using metal addition flame retardant. For this study, the experiments of flame retardancy conducted are as follows : burning ratio, weight loss rate using TGA-DTA, the measurement of LOI and char yield. And smoke mass concentration and CO yield were measured. The metal addition flame retardant reduced burning ratio and weight loss rate, increased the LOI and yield of char formation with decreased smoke mass concentration and CO yield.

A Study on Fire Characteristics of Carpet and Curtain Treated or Untreated with Flame Retardant (카페트와 커튼의 방염처리 및 사용여부에 따른 화재특성에 관한 연구)

  • Lee, Hae-Pyeong;Park, Young-Ju
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.74-81
    • /
    • 2007
  • In this study, we have evaluated the hazardous factors of fires such as heat release rate, smoke density, ignition temperature, and flammability of carpet and curtain used in the public facilities. As a result of flame retardant treatment, the heat release rate of materials treated with flame retardant was lower than that of not treated. However, the smoke density of treated materials was higher than that of not treated. Also, we have investigated the fire characteristics of used and unused carpet. As a result, the heat release rate and the smoke density of used for 3 years carpet were higher than those of unused carpet. The distinct differences of flammability and ignition temperature between used and unused carpet were confirmed.

Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood (합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度))

  • Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

An Experimental Study on Combustion Characteristics of Aluminum Composite Panels for Flame Retardant and General Materials (난연소재와 일반소재 알루미늄복합패널의 연소특성 비교에 관한 실험적 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Kim, Mi-Suk
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.105-111
    • /
    • 2012
  • In this research, aluminum composite panels of the general materials and fire retardant materials as building claddings make researches about fire performance comparison analysis. Test methods of the small and medium cone calorimeter experiments and SBI (Single Burning Item) experiments was applied to the determination. As a result, in the experiments peak heat release rate cone calorimeter the general aluminum composite panel $1,293kW/m^2$ ($75kW/m^2$), flame-retardant aluminum composite panel $70kW/m^2$ ($75kW/m^2$) was measured. In the SBI experiments fire growth rate the general fire aluminum composite panel is approximately 743 W/s and the flame-retardant aluminum composite panel is approximately 97 W/s of the value were measured. Thus, a standards enactment are urgently required in this case it is used as building claddings of the aluminum composite panel by fire risk assessment.

Combustion Characteristics of Fire Retardants Treated Wood (I) (난연처리 목재의 연소특성 분석(I))

  • Son, Dong Won;Kang, Mee Ran
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.96-103
    • /
    • 2015
  • The aim of this paper is to analyze combustion characteristics of treated woods by fire retardants which are prepared by several borate and phosphate compound solutions. The combustion characteristics for flame retardant treated wood were carried out using thermogravimetric analysis (TGA) to measure their combustion heat and flame retardant test using cone-calorimeter. The result of TGA and flame retardant test showed that single chemical solution affected the char forming and flame delay. The mixed retardants solutions was believed to be related to the efficacy and property of single chemical. The retention value and concentration of the retardants also affected the performance of fire retardant treated woods. The fire retardants FR1 and FR2 satisfied the requirement of The 3 Grade of Korean building codes.

Decay Resistance and Anti-mold Efficacy of Wood Treated with Fire Retardants (난연처리 목재의 방미 및 방부성능)

  • Son, Dong Won;Kang, Mee Ran;Lee, Dong-Heub;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.559-565
    • /
    • 2013
  • This study evaluated the ability of white and brown rot fungi to decompose fire retardant-treated wood by measuring mass loss. Anti efficacy of FRT against sapstain and mold fungi was evaluated. Wood was treated with liquid sodium silicate and boric acid, ammonium borate, di-ammonium phosphate. Retardant treated wood was then subjected to fungal decay resistance tests performed according to KS standard method using a brown-rot fungus, Fomitopsis palustris and white rot fungus Trametes versicolor. Aspergillus niger, Penicillium funiculosum, Rhizopus nigricans, Aureobasidium pullulans, Tricoderma virede fungi were used anti-sapstain and mold test. Boron and phosphorus chemicals used in this study increased the resistance of fire retardant treated wood against both fungal attack. Anti mold and sapstain efficacy of the fire retardant treated wood was excellent but there were difference depend on mold. After the liquid sodium silicate treatment, the second chemical treatment process could lead chemical fixation into wood, which effects decay resistance.