• 제목/요약/키워드: Fire-damaged concrete

검색결과 115건 처리시간 0.023초

SEM과 XRD를 이용한 수열온도별 화재피해 콘크리트의 Ca(OH)2 분석 (Analysis of Fire Damaged Concrete Ca(OH)2 by Heating Temperature Using Scanning Electron Microscope and X-ray Diffraction)

  • 임군수;한수환;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2022
  • In Korea, there is no clearly established technology for diagnosing and evaluating the damage depth of concrete structures created by fire. There have been cases of repairing, reinforcing, and demolishing degraded structures without diagnosing the damage depth. The commonly used phenolphthalein-based carbonate thickness measurement does not satisfy the complete disappearance condition of Ca(OH)2 in the interval where the relatively stationary flow declines after exposure to high temperatures. Even a small amount of Portlandite[Ca(OH)2] reacts with a red color, and the damage depth is misjudged. It was confirmed by X-ray diffraction and scanning electron microscope that Ca(OH)2 existed from 300℃ to 500℃ where the residual compressive strength decreased.

  • PDF

콘크리트 환경과 고온의 복합환경이 FRP 보강근의 계면전단성능에 미치는 영향 (The Combined Effect of Concrete Environment and High Temperature on Interlaminar Shear Strength of FRP Reinforcement)

  • 문도영;오홍섭
    • 콘크리트학회논문집
    • /
    • 제23권6호
    • /
    • pp.749-756
    • /
    • 2011
  • FRP 보강근의 화재 노출시 내구성능에 대한 연구들은 고온 노출이 인장성능에 미치는 영향에 대한 분석이 대부분을 차지한다. 그러나, 신설 구조물에 삽입된 FRP 보강근은 먼저 콘크리트 내에서 습윤환경 및 알칼리에 의한 성능저하가 발생하며, 이와 같은 FRP 보강 콘크리트 구조물에 화재가 발생하면, 보강근은 고온에 노출된다. 그러므로 화재에 의해 손상 받은 FRP 보강근의 평가시에는 콘크리트 환경과 고온에 의한 영향을 동시에 고려하여야 한다. 이 연구에서는 장기간동안 용액에 노출된 FRP 보강근에 $60^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$$300^{\circ}C$의 온도를 가하고, 계면전단강도를 측정, 비교 하였다. 실험 결과에 따르면, 환경과 고온의 복합영향이 FRP 보강근의 역학적 특성에 미치는 영향이 환경만의 영향 또는 고온만의 영향 보다 큰 것으로 나타났다.

천공저항시험에 의한 콘크리트 터널라이닝의 역학적 특성 추정 (Estimation of the Mechanical Properties of the Concrete Tunnel Lining by Drilling Resistance Test)

  • 최순욱;성연창;정호섭;장수호
    • 한국지반공학회논문집
    • /
    • 제23권11호
    • /
    • pp.87-98
    • /
    • 2007
  • 화재 후 터널 구조물의 신속한 복구를 위하여 화재손상 구간을 정확하고 빠르게 파악하는 것이 무엇보다도 중요하다고 할 수 있다. 본 연구에서는 화재로 인한 라이닝 콘크리트의 역학적 특성 변과를 라이닝의 두께방향으로 연속적으로 측정하기 위한 천공저항시험법을 제안하고, 천공시험으로부터 측정된 천공 변수들로부터 모르타르와 콘크리트의 역학적 특성을 추정하고자 하였다. 비교적 균질한 모르타르에 대하여 일련의 천공저항시험을 실시한 결과, 분당회전수가 1,300rpm, 관입속도가 1.40mm/sec, 그리고 비트직경이 10mm인 경우에 측정된 천공 반력값의 편차가 가장 작게 나타나 최적의 시험조건으로 판별할 수 있었다. 최적 시험조건에서 모르타르에 대해 천공저항시험을 실시한 결과, 천공반력과 모르타트의 압축강도 및 탄성계수 사이의 결정계수가 각각 0.91 및 0.93으로 나타나 양호한 상관관계를 도출할 수 있었다. 또한 콘크리트에 존재하는 골재의 영향을 고려하기 위하여 반력 에너지 개념을 제시하였고 실제 압축강도와의 결정계수는 0.94로서 역시 양호한 상관관계를 도출할 수 있었다. 이상과 같이 천공 비트의 관입과 동시에 연속적으로 재료의 역학적 특성을 추정할 수 있는 천공저항시험의 적용 가능성을 파악할 수 있었다.

고온에 노출 된 시멘트 매트릭스의 미세구조 특성 (Microstructure Properties of Cement Matrix Exposed to High Temperature)

  • 이건영;이건철;최중구;高山;허영선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.24-25
    • /
    • 2015
  • To secure fundamental materials for the performance change in concrete structure damaged by fire, this study analyzed SEM and XRD of hardened cement depending on high temperature conditions. As a result, at more than 200℃, SEM and XRD were not observed because of dehydration of Ettringite; at more than 500℃, calcium hydroxide was rapidly decomposed; at more than 700℃, calcium oxide was found; at 1000℃, the highest peak point appeared.

  • PDF

고성산불로 인한 시설물피해특성 연구 (A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun)

  • 염찬호;이시영;박흥석;권춘근
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.469-478
    • /
    • 2019
  • 연구목적: 본 연구는 산불에 의한 시설물피해 특성연구를 위하여 2018년 3월 28일 강원도 고성군 간성읍 탑동리 산16(야산)에서 발생한 산불(피해면적 40ha)을 대상으로 시설물피해 현황을 조사 하였다. 고성산불은 산림 및 농작물 피해는 물론이고, 사람이 거주하는 주택, 공공시설, 창고, 군사시설 등 17건의 시설물에 피해를 주었다. 본 연구의 목적은 이 피해 시설물들의 세부적인 피해원인을 분석하여, 산림인접 시설물들에 대한 산불피해 방지 방안을 제시하기 위하여 수행하였다. 연구방법: 고성산불발생시 기상을 분석하기 위해 산불발생과 진화완료시(2018.3.28 06:19 ~ 22:00)의 기상상황(기온, 풍속, 풍향, 습도)을 1분단위로 분석하였고, 시설물 피해 사례조사를 위해 고성산불로 인해 발생한 17건의 시설물 중 군사시설 등을 제외한 10건의 피해 시설물 주변의 경사도, 사면향, 지세특성, 산림과의 이격거리, 주요수종, 수관화발생 유무, 주택방위, 주택재질 등 9개 항목에 대한 현장조사를 실시하여 산불피해특성을 분석하였다. 연구결과:고성산불 발생과 진화완료시(2018.3.28 06:19 ~ 22:00)의 기상상황(간성 517AWS)은 기온 및 습도가 고온 건조한 상태였으며, 풍속은 평균 4.1m/s, 최대 11.6m/s의 강한 바람이 불었다. 주풍향은 W(225~315°)방향이었으며, 산불의 확산 방향과 일치하였다. 또한 산불피해 시설물들은 급경사지와 능선의 산정부에 위치하였고, 시설물주변 산림은 수관화 발생지역의 소나무 밀임분 지역이었다. 산림과 시설물과의 이격거리는 평균 13.5m이었으며, 시설물의 재질이 불에 강한 콘크리트였을 경우 경미한 피해를 입었지만, 샌드위치판넬 등 산불에 약한 재질은 모두 전소한 것으로 나타났다. 결론: 본 연구를 통해 얻은 결과인 주택주변의 숲 가꾸기 실시와 이격거리 확보, 시설물들의 불연재 재질로의 개선 등을 통해 산림인접 시설물들에 대한 산불방지 대책수립에 기여 할 것으로 기대된다.

잔골재 및 혼화재 종류에 따른 콘크리트의 폭열 성상에 관한 실험적 연구 (An Experimental study on Explosive spalling of Concrete According to Kinds of Fine Aggregate and Admixture)

  • 장재봉;김갑수;김재환;김용로;권영진;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.667-670
    • /
    • 2003
  • The purpose of this study is to present data for the reusing, reinforcement and estimation of safety of the RC structure damaged by fire, and for the prevention of explosive spalling by checking the character of explosive spalling according to kinds of fine aggregate, admixture and water-cement ratios. The materials used fine aggregates were sea sand, crushed sand and recycled sand, and the admixtures were fly ash and blast-furnace slag. Also the water-cement ratios was 55% and 30.5%. After those were heated respectively for 30 and 60 minutes in accordance with Standard Time-Temperature Curve. And then conditions of explosive spalling were divided into five grades, and characters of explosive spalling were investigated.

  • PDF

고강도콘크리트의 폭렬대책공법에 대한 국내외 현황과 성능적 구조내화설계를 위한 과제 (Trends of Research and Practical Use on Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete)

  • 권영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.935-940
    • /
    • 2008
  • 지금까지 콘크리트는 내화재료로서 일정한 두께만 확보하면 내화구조로 인정됨으로서, 콘크리트는 화재에 대하여 매우 우수한 소재로 알려져 왔다. 그러나 콘크리트가 고강도화 됨에 따라 부재의 내부 조직이 치밀화되어 화재 시에 발생되는 열응력 및 수증기압 등의 이유로 인하여 일정 이상의 고온에서 피복콘크리트가 심한 폭음과 함께 박리 박락되는 폭렬(Explosive Spalling) 현상이 발생되며, 이러한 폭렬현상은 철근콘크리트 부재 파편의 비산되는 1차 폭렬현상으로 인하여 피난자들의 인명안전성을 위협 할 뿐만 아니라 철근의 노출 및 부재단면의 감소되는 2차 폭렬현상이 발생됨에 따라 구조물의 붕괴로 이어질 수 있다는 것이 2005년 스페인 마드리드시의 윈저타워화재사례에서 경험한바있다. 이러한 사실은 2004년${\sim}$2008년도의 각종 매스컴 및 중앙일간지 등의 보도자료로 이슈화됨으로써 고강도, 초고강도 및 고성능 콘크리트의 내화성능에 대한 근본적인 재확인 작업이 요구되었으며, 2008년 5월에는 "고강도콘크리트 기둥 보의 내화성능 관리기준"이 국토해양부의 "건축물의 피난 방화구조 등의 기준에 관한 규칙"으로 고강도콘크리트에 대한 내화 성능확보 방안으로 개정되었고, 이에 따라 국내의 각 주요 건설사에서는 고강도콘크리트의 폭렬을 고려한 내화공법의 개발에 박차를 가하고 있다. 한편, 본 관리규정의 적절성에 대한 검증과 이미 축조된 구조물에 대한 대책 및 현재 선진 각국에서 시행되고있는 성능적 구조내화설계기법에 대한 대책 등이 향후 본 학회의 주요 과제로 됨으로써, 본 위원회에서는 폭렬메커니즘을 중심으로 한 제1차 전문위원회 연구발표를 2006년도에 시행하였고, 그 후 2년간의 각 건설업체의 내화공법개발현황에 대한 발표회를 통하여 현재의 국내 기술수준 및 현황을 파악하고 향후 진전방향등에 대한 토론을통하여 구체적인 추진방향을 모색하고자 한다.

  • PDF

중심 축하중을 받는 고강도 RC기둥의 섬유 혼입량에 따른 폭열 및 내화 성상 (Spatting and Fire Enduring Properties of High Strength RC Column Subjected to Axial Load Depending on Fiber Contents)

  • 한천구;황인성;이재삼;김경민
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.83-90
    • /
    • 2006
  • 본 연구는 PP 및 CL 섬유 혼입량 변화에 따라 제작한 고성능 K 기둥부재를 대상으로 화재를 상정한 내화시험 후 폭열 방지 및 내화성능을 검토한 것으로, 그 실험결과를 요약하면 다음과 같다. 굳지않은 콘크리트의 특성으로, PP 및 CL섬유 혼입량 증가에 따른 유동성은 섬유의 엉킴현상 등에 의해 플레인보다 저하하였고, 공기량은 다소 증감의 차이는 있으나 모두 목표 공기량의 범위를 만족하였으며, 경화 콘크리트의 압축강도는 섬유 혼입량 변화에 따라 50 MPa 전후의 고강도로 나타났다. 내화시험 후 RC 기둥부재의 폭열특성으로, 섬유를 혼입하지 않은 플레인은 전체적으로 심한 파괴폭열이 발생하여 철근이 노출되었고, PP섬유를 혼입한 경우는 내부 수증기압의 효과적인 배출로 폭열이 방지되었으며, CL섬유는 플레인보다 폭열 방지효과는 있으나, 모서리 부분에서 일부 파괴폭열이 발생하였다. 또한, 내화시험 후 폭열깊이는 표면보다 모서리에서 더 깊게 나타났고, 폭열발생면적율은 폭열방지 성능과 관계하여 PP섬유를 혼입한 경우가 가장 양호하였으며, 중성화깊이는 $6{\sim}8mm$ 전후의 유사한 깊이로 나타났다. 내화시험 후 잔존 압축강도율은 PP섬유를 혼입한 경우 40% 전후로 플레인의 20% 보다 크게 나타났고, CL섬유를 혼입한 경우는 25% 전후로 플레인과 큰 차이가 없었다.

800℃ 조건에서의 시멘트 경화체의 균열 특성 (Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃)

  • 지우람;박지웅;신기돈;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

고온 노출 시간에 따른 시멘트 페이스트 경화체의 푸리에 변환 적외분광 분석 (Cement Paste Hardened Body with High Temperature Exposure Time Fourier Transform Infrared Spectroscopy)

  • 김민혁;조현서;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.120-121
    • /
    • 2019
  • In this study, FT-IR analysis was performed by exposing cement paste to high temperature in order to characterize the change of hydration behavior of concrete structure damaged by fire accident. As the holding time increased, the Al-O vibration region increased due to the increase of Si-O symmetric Ca2(SiO4) and Brownilerite, and the OH stretching region tended to increase due to thermal decomposition of Ca(OH)2.

  • PDF