• Title/Summary/Keyword: Fire- and explosion safety

Search Result 403, Processing Time 0.021 seconds

A Study on the Explosion Hazard by Spark Discharge of the Lithium-Ion Battery (리튬이온전지의 불꽃방전에 의한 폭발위험성에 관한 연구)

  • Lee, Chun-Ha;Jee, Seung-Wook;Kim, Shi-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.14-20
    • /
    • 2010
  • This paper was studied on the explosion hazard by spark discharge of the lithium-ion battery. The experimental samples were chosen lithium-ion battery(general, notebook) which were used for source of portable equipment. The IEC(International Electrotechnical Commission) type spark ignition test apparatus and experimental gases such as methane, propane, ethylene or hydrogen were used for explosiveness test. It was confirmed through the experiment that the explosion hazard by spark discharge. Also, it was used thermal imager for confirm that spontaneous ignition possibility by short-circuit. As the result, this paper verified that lithium-ion battery should be used and designed by special attention safety in the hazardous zone which is existed explosiveness gas.

Measurement of Fire Point and Flash Point for Alcohols Using Tag Open-Cup Apparatus (Tag식 개방계 장치를 이용한 알콜류의 인화점 및 연소점 측정)

  • Ha Dong-Myeong;Lee Sung-Jin;Song Young-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.69-73
    • /
    • 2004
  • The flash point is one of the most important combustible properties used to determine the potential for the fire and explosion hazards of industrial material and the fire point is the temperature of the flammable liquid at which there will be flaming combustion, sustained 5 seconds in response to the pilot flame. In this study, the flash point and fire point were measured to present raw data of the flammable risk assessment for alcohols, using Tag open-cup apparatus(ASTM D 1310-86). The measured values were compared with the calculated values based on 0.78 times stoichiometric concentration. The values calculated by the proposed equations were in good agreement with the measured values.

A Study on the Risk Assessment Technique of the Underground Space -Focused on Prevention Policy of Fire and Explosion- (지하공간의 위험성 평가수법에 관한 연구 -지하가 화재, 폭발 방재 대책 중심으로-)

  • 박종근;노삼규
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.64-70
    • /
    • 2001
  • This study suggests fire, explosion safety assessment items and risk assessment technique for underground shopping malls by extracting dangerous elements in the management stage through examination of related accidents, documents and present conditions. This will also suggest importance of seven items to be key indices for a counterplan by classifying characteristics and trends of the large scale, depth and complexity of underground shopping malls.

  • PDF

Prediction of Explosion Limits of Ethers by Using Heats of Combustion and Stoichiometric Coefficients (연소열과 화학양론계수를 이용한 에테르류의 폭발한계의 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.44-50
    • /
    • 2011
  • Explosion limit is one of the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, the lower explosion limit(LEL) and upper explosion limit(UEL) of ethers were predicted by using the heat of combustion and stoichiometric coefficients. The values calculated by the proposed equations agreed with literature data within a few percent. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the other flammable ethers.

Safety Evaluation for the risk of explosion on Lithium Batteries (리튬전지의 폭발 위험성평가)

  • Kwon, Kyung-Ok;Kim, Yeong-Geun;Ma, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.371-375
    • /
    • 2011
  • 전지는 고에너지 밀도 제품으로 화학에너지를 전환시켜 전기에너지를 운반하는 것이다. 본 실험에서는 리튬 이온전지의 열적 안정성의 위험을 평가하기 위하여 리튬이온 전해액을 Differential Scanning Calorimeter(DSC)와 modified cloed pressure vessel test(MCPVT)로 분석하였다. 실험 결과 리튬전지는 다른 전지보다 위험하며, 전지를 잘못 사용하면 열적 반응성은 연소성 물질인 전해질을 포함하고 이것이 열을 발생시켜 폭발하거나 화재가 발생할 수 있음을 제시하였다.

  • PDF

A Study on the Comparison of Explosive Lower Limit Concentration & Thermal Specific of Wheat Powder Dust & Salicylic Acid Dust (밀가루분진 및 살리실산분진의 폭발하한농도 및 열적특성 비교에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.1-9
    • /
    • 2012
  • We have examined In order to compare each other from explosion and combustion characteristics about the dusts which collects from manufacturing process of wheat flour and cosmetics manufacturing process of functional Keratin removal soap at the small and medium enterprise style. We measured explosive pressure and explosive lower limit which follows in change of concentration change at the time of talc addition uses Hartman dust explosion apparatus, also measured weight loss and endothermic quantity uses DSC and TGA. The explosion test results show that increased explosive lower limit concentration and explosive pressure decreased by the increased ratio of the talc dust. And the DSC results show that heat flux and temperature decreased by the increased ratio of the talc dust. Also increased in raising temperature causes initial smoldering temperature to move towards low temperature section and the endothermic quantity increased on a large scale. Together the TGA results show that weight loss decreased by the increased ratio of the talc dust. From this research we have assured the successive dust explosion mechanism study will play a key role as a significant safety securing guideline against the dust explosion.

FIRE PROTECTION FOR PETROCHEMICAL PLANT

  • Suh, Jung-H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.244-251
    • /
    • 1997
  • Since 1970s, The Petrochemical Industry in Korea has grown rapidly by the successful economic growth. While the process became larger and more complex, hazardous chemicals have been used in large quantity, Therefore, the risk of a major accident such as fire, explosion and toxic material release has been increased. Korea has been ranked the fifth in petrochemical product capacity worldwide, also required to meet international standards on process safety management. Fire Protection System integral part of safely management in Petrochemical Plants, will be reviewed.

  • PDF

The Measurement of Combustible Properties of Acetic Anhydride for the Compatibility of MSDS (MSDS 적정성을 위한 아세틱안하이드리드의 연소특성치 측정)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.85-90
    • /
    • 2014
  • For the safe handling of acetic anhydride, this study was investigated the explosion limits of acetic anhydride in the reference data. And the lower flash points, upper flash points, and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower and upper explosion limits of acetic anhydride by the investigation of the literatures recommended 2.9 Vol% and 10.3 Vol.%, respectively. The lower flash point of acetic anhydride by using Setaflash closed-cup tester was experimented $49^{\circ}C$. The lower flash point acetic anhydride by using Tag and Cleveland open cup tester were experimented $55^{\circ}C$and $62^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for acetic anhydride. The experimental AIT of acetic anhydride was $350^{\circ}C$.

The Investigation of Compatibility of Combustible Characteristics for n-Tridecane (노말트리데칸의 연소특성치의 적정성 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.83-88
    • /
    • 2012
  • For the safe handling of n-tridecane, the lower flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower explosion limits by the lower flash points were calculated. The lower flash points of n-tridecane by using closed-cup tester were experimented $92^{\circ}C$ and $96^{\circ}C$. The lower flash points and fire point of n-tridecane by using open cup tester were experimented 100 oC and 103 oC, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tridecane. The experimental AIT of n-tridecane was 223 oC. The calculated lower explosion limit by using measured lower flash point 92 oC for n-tridecane was 0.6 Vol.%.