• 제목/요약/키워드: Fire- and explosion safety

검색결과 403건 처리시간 0.021초

정전기 화재·폭발 위험성평가 및 사고조사에 필요한 발생원인 변수 도출 (Derivation of Cause Variables necessary for Electrostatic Fire/Explosion Risk Assessment and Accident Investigation)

  • 변정환;박현곤
    • 한국안전학회지
    • /
    • 제39권2호
    • /
    • pp.9-21
    • /
    • 2024
  • Static-electricity-induced fires and explosions persistently occur every year, averaging approximately 80 and 20 cases annually according to fire statistics provided by the National Fire Agency and industrial accident statistics provided by the Ministry of Employment and Labor, respectively. Despite the relatively low probabilities of these accidents, their potential risks are high. Consequently, effective risk assessment methodologies and accident investigation strategies are essential for efficiently managing static-electricity hazards in fire- and explosion-prone areas. Accordingly, this study aimed to identify the causal variables essential for accident investigations, thereby facilitating risk assessments and the implementation of effective recurrence prevention measures to mitigate static-electricity hazards in fire-and explosion-prone regions. To this end, industrial accident statistics recorded over the past decade (2012 to 2021) by the Ministry of Employment and Labor were analyzed to identify major fire and explosion incidents and related industrial accidents wherein static electricity was identified as a potential ignition source. Subsequently, relevant investigation reports (63 cases) were thoroughly analyzed. Based on the results of this analysis, existing electrostatic fire and explosion risk assessment techniques were refined and augmented. Moreover, factors essential for investigating electrostatic fire and explosion disasters were delineated, and the primary causal variables necessary for effective risk assessments and scientific investigations were derived.

중소규모 건설현장 화학물질로 인한 화재·폭발 재해예방 사례연구 (Case Study on Prevention of Fire/Explosion Accidents caused by Chemical Substances in Small/Medium Sized Construction Sites)

  • 신운철;권준혁;이용수
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.63-70
    • /
    • 2014
  • There has been an increase in fire/explosion accidents caused by chemical substances used in new small/medium sized construction, reconstruction, or extension sites. There is vast room for improvement, especially in safety training, safety inspection, and selection of countermeasures because training, technicality, and management systems regarding fire/explosion risks in small/medium sized construction sites are very immature in most cases. The purpose of this study is to propose a differentiated technical, educational, and management application plan for preventative management of fire/explosion accidents caused by chemical substances used in small/medium sized construction sites.

폐플라스틱 열분해 유화 공정의 화재·폭발 위험성 및 안전관리 방안 (Fire and Explosion Hazards and Safety Management Measures of Waste Plastic-to-Pyrolysis Oil Conversion Process)

  • 서동현;최이락;임진호;한우섭
    • 신재생에너지
    • /
    • 제19권3호
    • /
    • pp.22-33
    • /
    • 2023
  • The number of fire and explosion accidents caused by pyrolysis oil and gas at waste plastic pyrolysis plants is increasing, but accident status and safety conditions have not been clearly identified. Therefore, the aim of the study was to identify the risks of the waste plastic pyrolysis process and suggest appropriate safety management measures. We collected information on 19 cases of fire and explosion accidents that occurred between 2010 and 2021 at 26 waste plastic pyrolysis plants using the Korea Occupational Safety and Health Agency (KOSHA) database and media reports. The mechanical, managerial, personnel-related, and environmental problems within a plant and problems related to government agencies and the design, manufacturing, and installation companies involved with pyrolysis equipment were analyzed using the 4Ms of Machines, Management, Man, and Media, as well as the System-Theoretic Accident Model and Processes (STAMP) methodology for seven accident cases with accident investigation reports. Study findings indicate the need for establishing legal and institutional support measures for waste plastic pyrolysis plants in order to prevent fire and explosion accidents in the pyrolysis process. In addition, ensuring safety from the design and manufacturing stages of facilities is essential, as are measures that ensure systematic operations after the installation of safety devices.

수소와 액화석유 가스의 공기혼합기의 폭발 후 화재로 전이 연구 (A Study on the Transition of Hydrogen-Air and LPG-Air Explosion to Fire)

  • 오규형;이성은;이광원
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.150-154
    • /
    • 2004
  • 실린더형의 내용적 6리터의 용기를 이용하여 수소와 액화석유 가스(LPG)의 폭발 특성을 측정하였고 270리터의 직육면체 용기를 이용하여 폭발 후 화재로의 전이 현상을 실험하였다. 폭발 특성은 strain type 압력센서를 사용하여 측정하였으며 폭발 후 화재로의 전이 현상은 고속카메라로 촬영하여 분석하였다. 실험 결과 완전 연소 농도 비보다 약간 높은 농도에서 최대 폭발압력을 나타내었다. 폭발압력 상승 속도와 화염 전파속도는 연소속도와 비례함을 알 수 있었으며 이러한 폭발 특성들은 폭발 후 화재로의 전이에 영향을 미침을 알 수 있었다. 또한 폭발 화염온도, 화염의 용기 내 체류시간 등도 폭발 후 화재로의 전이에 중요한 변수가 됨을 알 수 있었다.

재해분석을 통한 정전기 안전관리 수준 향상 방안 연구 (A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis)

  • 최상원;정성춘;박재석;양정열;변정환
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

Study on Hazard of Toner Cartridge at Recycle Facilities

  • Koseki, Hiroshi;Iwata, Yusaku;Lim, Woo-Sub
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.15-18
    • /
    • 2012
  • Because of development of printing technology, toner cartridge particle becomes smaller and more dangerous. And sometimes we had incidents with dust explosion of toner cartridge particle at recycling facilities in Japan. Therefore we studied on hazard of toner particle relating with dust explosion. We found that toner particle is so dangerous compared with most organic solids, even though it does not belong to hazardous materials in the UN regulation and the Japanese Fire Service Law.

노통연관식 보일러의 압궤사고 방지대책 (Measures for Preventing Pressure Fracture of Fire and Flue Tube Boiler)

  • 이근호
    • 한국안전학회지
    • /
    • 제19권4호
    • /
    • pp.14-19
    • /
    • 2004
  • Boiler is a hazardous equipment to have potential explosion ail the time. And not only it has malfunction at explosion. it lead to people death but also secondary accident such as explosion and fire. Therefore, this equipment should not be broken for keeping its own function. And also, high level of safety should be kept in the process of the use not to be malfunctioned. A large scale of accident due to boiler explosion can be preventive in advance. Boiler fracture is occurred by instant expansion (approximately 1700 time) from quick evaporation of rater in boiler, due to pressure decrease in boiler Emitting energy from it is tremendous and it is so dangerous because of its high temperature. Secondary explosion such as fire is also a main hazard occurring at fuel supply place. If any devices with high pressure is broken, then not only boiler vessel but also components of it are spread with high speed, causing secondary accident. This study is to analyze integrally accident cause of fire and flue tube boiler to have occurred pressure fracture actually, to show countermeasures to prevent accident loss from the fire and flue tube boiler.

레조르시놀의 화재·폭발 위험성 평가 (Hazard Evaluation on Fire and Explosion Characteristics of Resorcinol)

  • 이근원;최이락;송세욱
    • 한국가스학회지
    • /
    • 제17권4호
    • /
    • pp.45-50
    • /
    • 2013
  • 레조르시놀은 목재 및 타이어용 접착제, 합성수지 염료의 원료 등으로 널리 사용되고 있다. 이 물질은 상온에서 흰색 결정으로 분진은 공기 중에서 폭발성 혼합물을 형성할 수 있고 밀폐 공간에서 열에 노출 되었을 경우 폭발 위험성이 있다고 알려져 있다. 본 연구에서는 레조르시놀 취급시 화재 및 폭발 사고 등의 예방을 위한 해당 물질의 열분석, 열안정성, 분진폭발특성 및 최소점화에너지 등의 화재 폭발위험 특성을 평가하였다. 이들 연구결과는 레조르시놀의 사용 및 취급 시 공정의 안전 정보로 활용될 수 있을 것이다.

가스폭발 사고와 관련된 국가배상 사례의 분석 (Analysis of A Gas Explosion-Related State Compensation Case)

  • 이의평
    • 한국재난정보학회 논문집
    • /
    • 제16권1호
    • /
    • pp.44-59
    • /
    • 2020
  • 이 논문에서는 2층 건물 지하층의 다방에서 가스냄새가 난다고 119신고가 되어 소방대원들이 출동하여 옥상에 있는 LPG 가스통들의 밸브를 직접 잠그고 지하층 다방의 중간밸브의 잠금 상태를 확인하고 현장에 도착한 가스공급 및 설치 업자에게 안전조치를 취하도록 요구하고 철수한 후 7분 만에 가스폭발사고가 발생하여 2명이 사망하고 21명이 부상을 입은 사례를 분석하고 있다. 법원은 가스폭발사고의 원인이 규명되지 아니하였으므로 가스공급 및 설치 업자와 한국가스안전공사에 배상 책임을 물을 수 없고 안전조치를 하지 않고 철수한 소방기관에게만 배상책임이 있다고 판결하였다. 그러므로 가스가 누설된다고 119신고가 되는 경우에 출동한 소방대는 가스 밸브를 잠그고 사람들을 대피시키거나 접근하지 못하게 하고 환기를 시키는 등 안전조치를 하고 화재나 폭발가능성이 없음을 확인한 후 철수해야 한다.

화학공정의 위험성 평가를 위한 화재 폭발 지수 산정 프로그램의 개발 (Development of Fire and Explosion Index Estimation Program for Risk Assessment in Chemical Processes)

  • 김기수;백종배;고재욱;노삼규
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.58-63
    • /
    • 1993
  • Recently, a large amount of flammable or explosive materials have been handled or stored in chemical industries. H the equipments fail or the materials release in consequence of operation errors, fire and explosion could occur to them. Thus, risk assessment using quantification of risks is very important when design of processes and modifications of installed processes are performed. The purpose of this study is to develop the program for fire and explosion index in order to quantify the expected damage of fire and explosion incidents in chemical plants, to identify equipment that would be likely to contribute to the creation or escalation of an incident, to comunicate the potential fire and explosion risk to management and to account of damage cost.

  • PDF