• 제목/요약/키워드: Fire spread prevention

검색결과 96건 처리시간 0.022초

기후조건 변화에 따른 산불확산 변화 비교 (Comparison a Forest Fire Spread variation according to weather condition change)

  • 이시영;박흥석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.490-494
    • /
    • 2008
  • We simulated a forest fire which was occurred in Yangyang area on 2005 and compared a results between two different weather conditions(real weather condition and mean weather condition since 1968) using FARSITE, which is a forest fire spread simulator for preventing and predicting fire in USDA. And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. In the result, severe weather condition on 2005 effected a forest fire behavior. The rate of spread under real weather condition was about 4 times faster than mean weather condition. Damaged area was about 10 time than mean weather condition. Therefore, Climate change will make a more sever fire season. As we will encounter to need for accurate prediction in near future, it will be necessary to predict a forest fire linked with future wether and fuel condition.

  • PDF

화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰 (Analysis for Fire Spread through Double Skin Facade System with FDS)

  • 허윤택;박창복;성준식;윤명오
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-116
    • /
    • 2009
  • 본 연구는 Double Skin System의 화재 전파 위험성을 전산유체역학모델인 FDS를 이용하여 평가하였다. 화재모델링을 구현하기 위해 오피스 용도의 단위 구획공간을 화재지역으로 선정하였으며, 화재시나리오는 외창으로의 연소확대 위험 분석을 위하여 일반적으로 많이 설치되는 시스템조건들을 Case로 선정하여 분석하였다. 본 연구의 목적은 일반적으로 많이 사용되는 Double Skin System의 설치 간격에 따른 건물상층부로의 화재확대 위험성을 평가하고, 이에 따른 방화대책 등을 수립하는데 있다. 해석 결과, 더블스킨 중간층 간격이 넓을수록 상부층으로 연소확대 영향이 작은 것을 확인할 수 있었으며, 중간층 간격이 1m 미만인 경우는 발화층 상부 2개층으로 연소확대가 예상되므로 층간연소 확대 방지 시스템이 요구됨을 알 수 있다.

복합자재 화재확산방지구조에 대한 연구 (A Study on Flame Spread Prevention of Sandwich Panel)

  • 조남욱;김도현;심지훈
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.84-90
    • /
    • 2015
  • 복합자재(샌드위치패널)는 불연성재료인 양면 철판 또는 이와 유사한 재료와 불연성이 아닌 재료인 심재로 구성된다. 단열재를 가연성 재료로 사용하는 샌드위치패널은 화재 시 철판 내부로 화염이 확산되어 외부에서 진화가 어렵고 화염의 확산이 빠르게 진행되어 건물의 붕괴를 야기할 수 있다. 현행 건축법에 의해 샌드위치패널은 건축물의 용도 및 규모에 따라 난연성능을 확보하도록 하고 있다. 본 연구에서는 일부 외벽에 적용되는 화재확산방지구조를 복합자재에 적용하여 실제 규모의 화재시험을 통해 그 효과를 측정하였으며 향후 복합자재에서도 화재확산방지구조의 적용을 통해 복합자재 건축물의 화재안전 확보 가능성을 제시하였다.

샌드위치패널 건축물 플래시오버 지연을 위한 화재확산방지플레이트 시공방법 연구 (A Study on Flash Over Delay Effects on Applied Plate-Fire Spread Prevention Method at Sandwich Panels Structure)

  • 김도현;조남욱
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.79-87
    • /
    • 2017
  • 샌드위치패널은 양면이 철판이며 단열재로 접착된 특징을 갖는 건축자재로서 시공의 간편성, 자재비용의 경제성 등의 장점으로 공장 및 창고 구조물 등에 사용되고 있다. 그러나 샌드위치패널의 연속적 결합으로 시공되는 패널구조물은 패널과 패널이 연결되는 조인트 부위가 발생하게 된다 조인트부위는 화재시 철판의 용융과 변형으로 화염이 쉽게 유입되며 화재에 취약한 부위이다. 패널 내에 유입된 화염은 급속한 연소로 인해 화재확산을 유발하며 인명 및 재산피해를 발생시킨다. 본 연구에서는 샌드위치패널의 화재확산을 방지하기 위한 화재확산방지플레이트를 개발하였다. 이는 기존 선행연구에서 4면의 패널 접합면을 화재확산방지 재료로 시공하는 방법에서 접합면에 개발 플레이트를 끼우는 방식으로 시공이 용이하게 개선된 것으로서 패널과 패널이 결합되는 연결부에 자립하여 적용 가능하며 화염의 유입 및 화재확산을 방지하도록 고안하였다. 샌드위치패널 시험체에 대해 KS F ISO 13784-1 시험방법의 실물화재시험을 수행하였으며, 패널 연결부에 화재확산방지플레이트의 적용 유무에 따른 연소거동을 파악하고 그 효과를 측정하였다. 시험결과 패널 연결부에 화재확산방지플레이트를 삽입하는 것은 플래시오버의 지연, 시험체의 붕괴방지, 개구부의 온도상승을 지연시키는 것으로 측정되었으며, 효과적으로 패널구조물이 화재안전성을 확보할 수 있는 방안으로 확인되었다. 화재에 취약한 패널 연결부에 시공성과 경제성이 확보된 다양한 방식의 화재확산방지용 시공방법을 적용하는 것은 구조물의 화재안전성을 확보하는데 기여할 것으로 판단된다.

재래시장의 화재확산 방지를 위한 수막설비 설치 지침 (The Water Curtain Installation Guideline for Fire Spread Prevention in Market)

  • 최정욱;조성우
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

건축물 화재시 필요내화 시간 산정 및 간이식 도출 (Calculation of Fire-resisting Time and Extraction of Simple Transplants in the Event of a Building Fire)

  • 김윤성;한지우;김혜원;진승현;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2020
  • Large fires continue to spread throughout the building, including the fire in Uijeongbu in 2015, the fire in Jecheon in 2017, and the fire in Miryang in 2018. According to the above fire case investigation, major problems were the fire resistance performance of compartment members such as fire doors, the fire spread due to damage to exterior wall openings, and smoke spread through vertical openings. However, in South Korea, only specification design is implemented for buildings that are not subject to performance design. In addition, the analysis of the fire resistance performance standards of building members in the specification design showed that fire doors were not specified in detail for 60 minutes of insulation performance and 60 minutes of fire resistance performance of E/V doors, limiting the prevention of fire spread. Therefore, the purpose of this research is to prepare measures to prevent the spread of fire by presenting simple transplants for calculating the required fire time according to the architectural design conditions for the performance design of the components of the fire room according to the purpose of use of the front of the building.

  • PDF

필로티건축물의 화재확산방지를 위한 시범시공 (Trial Construction for the Prevention of Fire Spread in Piloti Building)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2019
  • In case of Korea, The Large-scale fire is consistently being such as 2015 Uijeongbu Fire, 2017 Jecheon Fire, 2018 Sejong Hospital Fire. Such a fire has a problem that the fire is spreading upper due to external flame spread. As a countermeasure the fire safety, the study about axial temperature prediction of external flame spread is consistently doing. But in korea, Vertical spandrel is specified as 40cm, and improvement is urgently needed. In this study, a repair material was selected to prevent the fire from spreading to a building where a flammable exterior material was installed and then pilot construction was carried out. Also, fire safety measures for buildings constructed with flammable exterior materials were examined.

  • PDF

산불 지표화의 1차원 화염전파 모델의 수치해석 연구 - 평지조건 기반에서 - (A Numerical Study of 1-D Surface Flame Spread Model - Based on a Flatland Conditions -)

  • 김동현;전중효의;통본규우;이명보;김광일
    • 한국화재소방학회논문지
    • /
    • 제22권2호
    • /
    • pp.63-69
    • /
    • 2008
  • 산불의 확산특성은 일반적으로 가연물의 특성, 지형, 바람조건과 같은 기상 상태등과 관련이 있다. 산불의 발달과정에 있어 수치해석을 통한 확산예측 모델은 열전달 과정에 기본을 둔 열에너지 전달에 대한 해석이 가장 일반적인 방법론이다. 산불의 발생시 열에너지의 전파속도를 해석하는 것은 화염의 생성과 열전달, 그리고 소멸에 이르는 전 과정에 대한 물리적, 화학적 해석을 통해 화염의 이동에 따른 전파속도로 추정할 수 있다. 본 논문에서는 고체연소물질의 표면화염전파에 대한 수치해석을 통해 1차원 지표화 확산모델식을 제시하였다. 1차원 확산모델식은 평지상태에서 풍속조건에 따른 화염의 전파속도 산정식으로써 지표연료의 화염유지시간, 화염의 높이, 화염의 온도, 지표연료의 착화온도 등에 대한 실험 및 이론식을 적용하였다. 실험값 및 다른 모델식과의 ROS 비교 결과, 풍속 3 m/s 이하의 조건에서는 지수함수식의 증가곡선을 나타내는 경향을 보였다. 침엽수종인 소나무 낙엽에 대한 수치해석값과 실험값을 비교한 결과, 풍속 1-2m/s 조건에서는 확산속도가 약 10% 상향예측이 되었고 풍속 3m/s 조건에서는 약 20% 하향예측 되었다. 따라서 앞으로 지표화 확산 예측을 위해 본 연구결과에서 얻어진 화염확산 알고리즘을 이용한 초기 산불확산 예측 적용이 가능할 것으로 사료된다.

산불확산 시뮬레이션 도입을 위한 FARSITE 고찰 (Research on FARSITE for introducing a Forest fire simulator)

  • 이시영;박흥석
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.161-164
    • /
    • 2008
  • We studied a basic concept and application about FARSITE, which is a forest fire spread simulator for preventing and predicting fire in United States Department of Agriculture(USDA). And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. For this transition, we compared the behavior of the 2005 Yangyang forest fire with the result of a simulation. The spread direction is similar to real data. But, while mean spread of rate was 0.65km/hr on real data, it was 0.3km/hr on simulation. As Damaged area is 1,387ha on real, it was 5,368ha on simulation. Therefore, it is necessary to establish a fuel concept for more accurate simulation.

  • PDF

원예식물을 식재한 화재확산 방지용 벽면녹화 기술연구 (A Study on the Recording Technology of Fire Propagation Prevention Wall Using Horticultural Plants)

  • 문종욱;임서형
    • 한국재난정보학회 논문집
    • /
    • 제14권2호
    • /
    • pp.107-114
    • /
    • 2018
  • 연구목적 : 본 연구는 전통시장의 화재확산 방지를 위해 지붕 위에 적용한 벽면녹화 기술을 활용한 벽체개발이다. 연구방법 : 개발한 벽면에서 설치된 살수헤드는 평상시에 식물을 위해 사용하다가 화재발생시 인접 건물로 화재가 확산되지 않도록 할 수 있도록 살수배관 겸용 사용이 가능하도록 설계하였다. 또한, 벽면에 식재된 식물의 생장을 위하여 최 상층부 및 일부 구간에 살수헤드를 부착하여 필요시 살수 할 수 있는 시스템을 구축하였으며, 화재발생과 같은 유사시에 보다 많은 양의 물을 살수하여 화재확산방지효과를 극대화 할 수 있도록 설계하여 객관성을 입증하고자 하였다. 연구결과 : 이러한 기술을 통해 전통시장과 같이 밀접건물 상층부에 설치 가능한 벽체개발을 제안하였으며, 구조물과 스프링클러와의 일체형으로 별도의 차단설비가 불필요하게 설계하였다. 그리고 스프링클러가 식물의 살수와 화재확산방지 기능을 동시에 수행이 가능하다. 이는 국내에서 유일하게 제안한 화재확산방지용 대안기술이라 판단된다. 결론 : 본 연구에서는 화재확산 저감효과의 정량화 성능 도출을 위해 직접 디자인한 벽체설계를 통해 벽면시스템의 화재진압 방법, 그리고 벽면자체의 내구성 및 난연성능을 검증하였다.