• Title/Summary/Keyword: Fire sign

Search Result 56, Processing Time 0.024 seconds

Study on Correspondent of Astrology and Jung's Psychological Types -Focused on earth, water, fire and wind(Four major factors)- (천문 점성학과 융의 심리학적 유형과의 연관성 -지수화풍(地水火風) 4대(四大)와의 관계를 중심으로-)

  • Lee, Yong-Chol;Kim, Byung-Soo;Kang, Jung-Soo
    • Journal of Haehwa Medicine
    • /
    • v.18 no.1
    • /
    • pp.117-127
    • /
    • 2009
  • Study on correspondent of eastern and western astrology and Jung's psychological types, we obtain as follow as results. Western astrology is transmitted from China and developed, it influenced on the study of the Four Pillars(四柱學). Comparing assemble, gathering, punishment, destruction, collision, impair of Di-zhi(地支) in the study of Four Pillars with Xing-gong theory(星宮論) in the western astrology, can get the result that the Pillars study has close connection with astronomy and astrology. When we compared Jung's psychological types with astrology, the five elements(五行) and the four major factors, can be summarized like this. (1) intuition-fire sign-wood and fire-fire in the four major factors(四大), (2) sensation-earth sign-earth and metal-earth in the four major factors, (3) thinking-air sign-metal and water-wind in the four major factors, (4) feeling-water sign-water and wood-water in the four major factors. The four major factors of Buddhism is now understood as, earth, water and fire represent the state of solid(earth), liquid(water), gas(fire) and wind can be recognized as energy source help the changes. This is mentioned throughout the books, but only arranging the theory of four major factors.

  • PDF

Design, Fabrication, and Performance Evaluation of Showing Material for Early Expression of Fire Signs and Combined Inspection (화재징후 조기표출과 복합검사를 위한 표출재 설계, 제작 및 성능 평가)

  • Dongcheol Shin;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.187-193
    • /
    • 2023
  • Previous research has explored early expression of fire signs before the burning of insulation. To achieve this, typically, automatic inspections are used to detect gas emitted from odor capsules at electrical connection points; additionally, early fire signs can be expressed using visual inspection of changes in the appearance of temperature caps. However, early detection of electrical fire is often difficult because only specific inspections, which are not complex, are performed. Therefore, in this paper, we present complex inspection techniques, such as visual inspection, odor inspection, and automatic inspection, and propose a showing material of fire signs that can solve conventional problems. In addition, this study examines the conditions under which the candidate material for the showing material is designed, the composition of the candidate material selected based on the designed conditions, the manufacturing means used to produce the showing material considering the temperature for early expression of fire signs, and the performance of the produced showing material. Furthermore, we analyze various effects that can occur through the proposed display material.

Study on the Development of Concrete Public Sign Block (콘크리트 공공 사인 블록 개발에 대한 연구)

  • Lee, Ung-Kyun;Lee, Sung-Chul;Kim, Jong Yoon;Kim, Baek-Joong
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.266-274
    • /
    • 2021
  • Purpose: The purpose of this study is to develop a concrete public sign block for floors that can provide pedestrian safety and various information. Method: In order to achieve these research objectives, step-by-step block manufacturing techniques applied in relation to the development of public sign blocks were proposed, and the field applicability of the developed concrete public sign blocks was evaluated. Result: The concrete public sign block for floors developed in this study is expected to be capable of expressing public signs of various shapes and to reduce manufacturing cost. As a result of the usability evaluation for two years, no problems such as cracks, edge dropouts, discoloration, and abrasion were found, so it is judged that sufficient durability was secured. Conclusion: Based on these research results, it is expected that the concrete public sign block will be used as an alternative to secure the weaknesses such as stickers, stone and brass plates that have been used in the existing public sign for floors. It is expected that it can be applied in various fields.

The Necessity of Introducing Fire Point Notification Displays in Complex Buildings to Reduce Required Safe Escape Time(RSET) (RSET 감소를 위한 복합건축물의 화재발생지점 알림표시등 도입 필요성)

  • Jusung Kim;Jongkwen Ha;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.71-82
    • /
    • 2024
  • In modern society, buildings are becoming more complex, and the population is becoming more densely populated. Such large buildings require a variety of evacuation measures, as there is a high possibility of large-scale human casualties due to increased evacuation distance and evacuation time in the event of a fire. Strobe light and exit sign light are used as important evacuation equipment to provide early warning and evacuation directions. In this thesis, we conducted a fire simulation assuming that a fire occurrence point notification function and a strobe light function were added to equipment such as visual alarms and evacuation guidance, and compared and analyzed the difference in evacuation completion time with existing equipment. The scenarios for the simulation were divided into "general fire situations" and "fire location and evacuation exit guidance situation" and the differences in evacuation completion time in the event of a fire were compared and analyzed for each floor from the 1st floor to the 3rd floor. The maximum travel distance to complete evacuation in the case of a fire on the first floor decreased by 80.6 m and the evacuation completion time decreased by 329.4 seconds, and the maximum travel distance to complete evacuation in the case of a second-floor fire decreased by 28.5 m and the evacuation completion time by 438.8 seconds. During the fire on the third floor, the maximum distance decreased until evacuation was completed to 3.4 m, and the evacuation completion time was reduced by 355.6 seconds. It is expected that if the congestion level of evacuation routes is reduced by utilizing the congestion level of evacuation exits when fire alarm systems and evacuation equipment are activated, the evacuation completion time will be further shortened and evacuations will be carried out quickly and safely.

Optimal Display Method Considering the Display Element and Color of Fire Shutter Door (방화셔터 출입구의 표시 요소 및 색상을 고려한 최적 표시방법)

  • Son, Jong-Yeong;Hong, Won-Hwa;Bae, Young-Hoon
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.67-72
    • /
    • 2018
  • A fire shutter is installed to prevent the movement of fire or smoke when a fire occurs inside a building. Fire shutters have access doors for passengers. On the other hand, the present fire shutter door display regulation is only required to be displayed in a different color from the surroundings. Hence, the risk of people not being able to recognize the door of the fire shutter is quite high, and the danger increases further in a smoke situation. Therefore, this study attempted to find a way to mark a fire shutter door that can be recognized even when smoke is spreading. First, a preliminary questionnaire was used to draw three factors to mark the fire shutter door (sign, door background, and edge). The experiment type was set by combining 5 colors for the three derived factors. The experiment was conducted on a total of 122 male and female participants. The results showed that a yellow background, red sign, and red edge have the highest awareness in a normal visual field without smoke. This was also the same in the field of view in the case of a fire with smoke, but the red background, yellow sign, and yellow edge were most noticeable in the case of dark smoke.

A Safety Evaluation of Cable Tunnel Exposed to Fire (화재피해 통신구의 안전진단)

  • 김지상;김형우;김효환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.221-226
    • /
    • 1994
  • A safety evaluation of cable tunnel, which is a concrete box structure with telecommunication facilities in it, exposed to fire is given. The immediate field observation was performed to find out any sign of sudden structural failure. In some region, where the fire intensity was heavy, the spalling of concrete cover in upper slab occurred. Next, more careful investigation was done with proper non-desturctive testing methods and structural analysis taking into account the changes in material properties due to fire. It seems that there is no severe damage on concrete, reinforcements and over all structural system.

  • PDF

Development of a Classification System for an Electrical Fire Investigation (전기화재 조사를 위한 분류체계 개발)

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

A Study on the Remote Control for Exit Sign Using High Efficiency LED (고효율 LED를 이용한 유도등의 원격제어에 관한 연구)

  • 백동현;홍석표
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2002
  • In the normally, exit sign is always lighting on status by the connected to normal electrical source. So, there are happened to rise of the economical cost such as power consumption, maintenances and repair replacement of lamp etc. This paper are study on the new exit sign circuits by using high efficiency LED that is available for remote control and reduceible to power consumption, maintenance cost by the way of compensation fluorescent and incandescent lamps. As a results on the study, exit sign lamp is capable of control and supervisory in trigger angle by the remote control switch, widely and easily. And then, the response time was very fast in 600〔$\mu$s〕and also it can be find that the rising and fall time of oscillate circuit is maximum 200〔ns〕 as high sensitively. Finally, it obtain to the result that reducible of electrical power consumption and not required for replacement of lamp by using the high efficiency LED lighting source.

Gantry Robot with Extended Workspace for Pavement Sign Painting Operations

  • Hong Daehie;Lee Woo-Chang;Chu Baeksuk;Kim Tae-Hyung;Choi Woo Chun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1268-1279
    • /
    • 2005
  • The current method for pavement sign marking operations is labor-intensive and very dangerous due to the exposure of workers to passing traffic. It also requires blocking traffic for a long period of time resulting serious traffic jam. This paper deals with the development of a robotic system for automating the pavement sign painting operations. The robotic system consists of gantry frame equipped with transverse drive rail and automatic paint spray system. The workspace of the gantry robot is extended to one-lane width with the transverse rail system. This research also includes the development of font data structures that contain the shape information of pavement signs, such as Korean letters, English letters and symbols. The robot path is generated with this font data through the procedures of scaling up/down and partitioning the signs to be painted depending on the workspace size.