• Title/Summary/Keyword: Fire safety manager

Search Result 32, Processing Time 0.023 seconds

The Efficient Management Plans for the Lightweight Partition Walls and Evacuation Space in Apartment Houses (아파트에 설치된 경량칸막이 및 대피공간의 관리방안 모색)

  • Shin, Hyo-Jin;Yun, Ji-Hui;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2015
  • This study classified the study subjects as apartment residents and managers, and conducted the descriptive statistics of research questions related to the effectiveness of the lightweight partition walls and the evacuation space. This study also conducted T-test and Anova to find the different perceptions of the lightweight partition walls and the evacuation space, and the different perceptions of related laws according to the characteristics of the residents and managers. The findings and suggestions were as follows. Firstly, strengthening of the Senior Fire Safety Manager system to prevent the insolvency of fire safety management due to the affiliate. Secondly, implementing enhanced penalties in accordance with not implementing residents education, in order to prevent not smoothly delivering manager trained education to residents. Thirdly, adjusting hands-on training time according to the gender of the managers to supplement women's relatively low perceptions of lightweight partition. Fourthly, mandating evacuation guidance stickers on the evacuation space for residents to remove obstacles in the evacuation space. Finally, establishing regular residents education system in order to improve the awareness of the related laws for residents residing over 16th floors.

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

The Present Situation and Preventive Measure of the Fire in the Cattle Shelter -Based on Jeonbuk Province- (축사 화재의 현황과 그 방지 대책 -전라북도를 중심으로-)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.81-87
    • /
    • 2007
  • The cattle shelters have been badly damaged by the recently large fires. so the reconstruction of the damaged shelter is very difficult. In the light of the seriousness of the fire like that, the preventive plan for the cattle shed should be thoroughly established. The preventive measure which the fire department performs presently is limited to the stopping the fire before it starts. More than anything else, The men who operate and manage the cattle shelters must know what to do. The written plan will assist them. To begin with, The fire authority should clearly specify how cattle should be protected from any outbreak of fire. Clear access to each fire shed is very important to protect the cattle safely. The manager of the cattle shelter should get ready for the fire defense equipment. Most fires of the cattle shelters are due to electricity faults. These renovations should be performed and checked immediately. Therefore, The manager should be ready assist fire chief or the professional organization to prevent the electricity fire. Fire Safety education should be planned for the owner and staff so all should know what is expected in case of a fire. The Fire Department will check the access road, the equipment available and an announced fire drills should take place every year in the cattle shelter. The Fire Department should check the access road, equipment for preventing fires and staff training each year.

Analysis of the Evacuation Safety of Indoor Stadiums with Automatic Opening/Closing Exit Installations (출입문용 자동개폐장치를 설치한 실내체육관의 피난안전성 분석)

  • An, Jae-Chun;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.15-21
    • /
    • 2020
  • This study analyzed the evacuation time in indoor stadiums when exits that automatically open/close when the fire sensor is triggered are installed as a means to improve the problem of closing certain exits. Firstly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 529.8 seconds when the automatic opening/closing exits are broken and employees are not present. Secondly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 445 seconds when the automatic opening/closing exits with 750mm width are working but employees are not present. Lastly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all spectators was 337 seconds when the automatic opening/closing exits with 1,500mm width are working and employees are present. As a result, it was revealed that the evacuation time is shortened when the automatic opening/closing exits are working. Additional comparative studies with actual simulations of people evacuating an indoor stadium and firefighting simulations considering smoke flow are necessary.

Analysis of Safety Management Operations of Fire Risk Factors in Small-Scale Construction Sites (소규모 건설현장 화재 위험요인 안전관리 운영실태 분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.775-785
    • /
    • 2022
  • By analyzing the operation status of fire safety management of small construction site workers, deriving problems, and suggesting improvement measures, this study was conducted to present practical basic data for their efficient use in the future, and the following conclusions were drawn. First, it was analyzed that small construction site workers are elderly in the age group of construction workers, have short construction skills, most of the jobs are working in the construction industry, and the employment type is non-regular workers. Second, the fire safety management improvement plan of small construction site workers is systematized, fire safety manager is deployed to manage fire risk, fire escape routes and emergency warning facilities are provided to inform all workers at the construction site. In addition, measures to reduce industrial accidents are needed through realistic evacuation training, fire VR training, and interesting educational programs.

Policy Direction for Fire Products Life Expectancy Legislation (소방용품 내용연수 제도화 정책방안)

  • Baek, Chang Sun;Park, In-Seon
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.111-120
    • /
    • 2016
  • This study is intended to provide legislative direction for fire products life expectancy. Domestic and international laws relating to fire products life expectancy have been reviewed, and the results of a Fire Safety Manager Consciousness (FSMC) survey were analyzed. The FSMC survey has been designed in order to assist with the establishment of appropriate fire safety policy. A questionnaire survey was conducted with 660 fire safety administrators from 17 municipal and provincial districts, with the intention of gaining expertise on the extension of life-span for 32 fire products. The survey also asked for candidates opinions on future policy direction. Based on the survey results and the review of policies within other nations, we have devised a set of policy issues with the intention of extending the life-span of fire-safety items. The survey result revealed that 79.3% of Fire Safety Managers (FSMs) concurred with the establishment of legislation regarding the maintenance and correct care of fire-safety products. Overall, over 30% of FSMs were in favor of regulations regarding Ddry chemical fire extinguishers (77.3%), fire detectors (44.6%), fire hoses (44.4%), gaseous agent fire extinguisher (40.6%), automatic descending life lines (36.2%), exit lights (35.9%), air respirators (35.9%), extinguishing systems for residential cooking facilities (33.9%), automatic spray-type extinguishing units (33.9%), emergency lights (31.2%), and gas leakage detectors (30.7%). Especially, among these, dry chemical fire extinguishers (60.0%), detectors (20.0%), and fire hose (18.8%) were identified as the fire products primarily in need of maintenance legislation. The general consensus is that fire products older than 10 years need to be replaced. Based on the survey results, there was general agreement that fire product life expectancy is in need of legislation. This study recommends the introduction of fire product life expectancy legislation in phases.

A Case Study of Disaster Accidents at Construction Site Based on PDCA Theory

  • Shin, Dong-Won;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.3
    • /
    • pp.245-256
    • /
    • 2021
  • This study is significant in determining the reduction of safety accidents by applying PDCA's theory by subdividing it into a case analysis technique for construction sites by PDCA's theory. For this study, accidents accounted for the largest proportion of each type of disaster in the construction site were considered, and safety accidents were reduced through the PDCA theory through prior research. The analysis method of this study derived improvement plans by applying PDCA techniques to plan, implement, confirm, review, and improve disaster accidents at construction sites. The conclusions of this study are as follows. In the plan, first of all, measures shall be taken to prepare a safety management plan, to verify the implementation of the plan, and to verify the degree of implementation by the field manager. In the implementation, first of all, it is necessary to introduce a safety education history system to strengthen the safety education curriculum to suit the site, as long-term work is impossible for field workers depending on field conditions. First of all, it is necessary to strengthen the installation of safety facilities, including "work scaffolding" and "conducting prevention facilities" at construction sites. In management review and improvement, the risk assessment system for construction sites needs to be expanded first°.

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

A Study on the Revitalization Method of the Korean Volunteer Fire Brigade (한국의용소방대의 활성화 방안에 관한 연구)

  • Lee, Jeom-Dong;Yoon, Myong-O;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.95-104
    • /
    • 2008
  • It is essential that the operational system of volunteer fire brigade (VFB) playing a important role in the local disaster prevention should be effectively improved to live in safety by protecting life and property of inhabitants from a disaster. The results of this research showed that most of volunteering members of fire brigade was highly satisfied with their works and thus they voluntarily did volunteer activities. It was also found that the development of the professional education program and training course about disaster prevention should be required because members of the volunteer fire brigade lacked expertise about the disaster prevention. Moreover, in order to activate and expand VFB, the establishment of the fundamental ideology about the activities of VFB, the introduction of effective selection examination system for the VFB and the creation of department fully responsible for the management of the VFBs should be necessary as well.

A Study on the Effective Method to Producing Data for The ROKA Live Fire Training Range Safety (한국군 실 사격 훈련간 효율적인 안전지대 데이터 구축 방안 연구)

  • Lee, June-Sik;Choi, Bong-Wan;Oh, Hyun-Seung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.64-77
    • /
    • 2015
  • An effective method for produce munitions effectiveness data is to calculate weapon effectiveness indices in the US military's Joint Munitions Effectiveness Manuals (JMEM) and take advantage of the damage evaluation model (GFSM) and weapon Effectiveness Evaluation Model (Matrix Evaluator). However, a study about the Range Safety that can be applied in the live firing exercises is very insufficient in the case of ROK military. The Range Safety program is an element of the US Army Safety Program, and is the program responsible for developing policies and guidance to ensure the safe operation of live-fire ranges. The methodology of Weapon Danger Zone (WDZ) program is based on a combination of weapon modeling/simulation data and actual impact data. Also, each WDZ incorporates a probability distribution function which provides the information necessary to perform a quantitative risk assessment to evaluate the relative risk of an identified profile. A study of method to establish for K-Range Safety data is to develop manuals (pamphlet) will be a standard to ensure the effective and safe fire training at the ROK military education and training and environmental conditions. For example, WDZs are generated with the WDZ tool as part of the RMTK (Range Managers Tool Kit) package. The WDZ tool is a Geographic Information System-based application that is available to operational planners and range safety manager of Army and Marine Corps in both desktop and web-based versions. K-Range Safety Program based on US data is reflected in the Korean terrain by operating environments and training doctrine etc, and the range safety data are made. Thus, verification process on modified variables data is required. K-Range Safety rather than being produced by a single program, is an package safety activities and measures through weapon danger zone tool, SRP (The Sustainable Range Program), manuals, doctrine, terrain, climate, military defence M&S, weapon system development/operational test evaluation and analysis to continuously improving range safety zone. Distribution of this K-range safety pamphlet is available to Army users in electronic media only and is intended for the standing army and army reserve. Also publication and distribution to authorized users for marine corps commands are indicated in the table of allowances for publications. Therefore, this study proposes an efficient K-Range Safety Manual producing to calculate the danger zones that can be applied to the ROK military's live fire training by introducing of US Army weapons danger zone program and Range Safety Manual