• Title/Summary/Keyword: Fire safety law

Search Result 159, Processing Time 0.024 seconds

A Case study on the Escape Performance of Apartment Buildings (사례를 통한 공동주택의 피난성능에 관한 연구)

  • 이용재;이범재
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.59-69
    • /
    • 1998
  • As high-rise Apartment buildings increase the importance of fire prevention and escape performance. While these buildings provide dwellers with much more houses, they have the basic escape safety problem in their apartment buildings. In these respect, this study aims to present the Principles of Fire protection for the escape performance of apartment buildings. This study reviews basic theories of escape in apartment buildings. I figure out the characteristics of the fires in apartment buildings by case studying the fire in the apartment buildings, and find out the existing problems for escape performance and fire prevention by surveying. In this study, the major findings are as follows: The planning method should be based on the escape performance. In the planning stage, fire safety should be considered more seriously than law and economic factors.

  • PDF

A Study on the Establishment of Process Safety Management (PSM) System for Small and Medium Size Chemical Plants (중소화학공장의 공정안전관리(PSM)시스템 구축에 관한 연구)

  • Baek Jong-Bae;Ko Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.8-13
    • /
    • 1999
  • The article 49-2 of Industrial Safety Law requires that all the owners of industrial plants which contains dangerous facilities perform the process safety management. That is, this law requires the owners of industrial plants to take necessary measures to prevent fire, harmful gas leaking, explosion, and other serious accidents that could cause demage and injuries to the employees. So far, domestic chemical plants have tried to invest money and time in safety management. But, such efforts have been made only in chemical plants that were subsidiaries of large business groups. Moreover, since the economic crisis of Korea which is symbolized by the IMF bailout, small and medium size companies could not afford to invest in safety management. Their major concern is to increase productivity and thereby, survive in this crisis. The goal of this research is to develop the process safety management system that can help small and medium size companies to positively secure the process safety management. So, in developing the process safety management system, the financial and practical difficulties of such companies are fully taken into consideration.

  • PDF

Improving the Safety Regulation For Self Contained Breathing Apparatus (특정소방대상물의 공기호흡기 안전규제 개선방안)

  • Lee, Sang-Pal
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.45-51
    • /
    • 2010
  • The objective of this study to analyse the cause and pattern of failing to use in Self Contained Breathing Apparatus using by government regulation for producer and client. Regulation for producer is related to legal and institution of safety inspectiontest of SCBA. Rregulation for client is preventive maintenance. Improving fail in use of SCBA are following. First, expansion of ad hoc collection inspection and safety checking is required. Second, the strict application of the law for monitoring and auditing disposal procedure in low performance SCBA is required.

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

A Study on the Safety and Improvement of Small Theatres in Korea (소규모 공연장 안전실태 및 개선방안에 대한 연구)

  • Park, Yong Gyu;Kim, Dong Kyun;Park, Jin Kyu;Kim, Kyung Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.22-27
    • /
    • 2014
  • The market of performance arts industry such as concert, musical and opera etc is now expanding in Korea. However, the inadequate safety management in theatres often causes some accidents. The guarantee of safety in theatres is very important since the accidents in theaters can lead to many casualties and serious property damages. In particular, the small theatres which have no obligation of safety inspection by law are very vulnerable to safety mattes. This study has done the research into the improvement of safety in small theaters through the inspection and analysis of their safety status. For the purpose, this study has inspected and analyzed the safety status of small theaters over 120 in the field of theater management and operation, fire protection, electrical facilities, ceiling structure and etc. Moreover, this study had investigated the law and technical standards related to theatre safety. This study shows that the essentials to make sure of the safety in small theaters are (1) the education to improve the sense of security of people who work in theaters (2) the training to strengthen the operating skills of the facilities in theaters (3) the cooperation and support of the related organization such as technical research center, central and local government.

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

A Study on PBD case of Evacuation in Japan for PBD Approach of Korea. (국내 PBD 기술의 정립을 위한 해외 성능적 피난안전설계사례에 관한 조사)

  • Kim, Dong-Eun;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.322-327
    • /
    • 2008
  • Fire safety provisions have to be determined through Performance -based design in many project. There is a need for quick estimation of evacuation time for scenario analysis in hazard assessment. The key equations on estimating evacuation time have to be known. In Japan There are many experience of PBD according to the Architectural law. It is the aim of this study to investigate the PBD case of Evacuation in Japan for PBD Approach of Korea.

  • PDF

The Study on fire fighting equipment development for cultural asset fire precaution (문화재 화재 예방을 위한 소방장비 개발에 관한 연구)

  • Kim, Yoo-Shik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.238-245
    • /
    • 2010
  • This research is safety administration turkey and research for improvement of a lot of cultural asset to butyric acid officer and whole country since Sungryemunhwajae, and is preventing by meantime Cultural Properties Protection and fire fighting relevant law to protect these cultural asset but want is not few in cultural asset fire precaution yet. Therefore, I wish to study about operation and application standard of water system system that is applying to supplement these problem.

  • PDF

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.

Strategy about Support System for Victims of Fire Cases through the Analysis of A Fire Cases (화재사례분석을 통한 화재피해자 지원체계 구축방안)

  • Cha, Jong-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.196-202
    • /
    • 2018
  • There have been more than 40,000 cases of fires in Korea in the last three years. However, as 'Accidental Fire Liability Act' was judged to be non-conform to the Constitution in 2007, the damages by light mistakes should be compensated. Accordingly, disputes such as compensation claims, litigations and indemnification cases of the victims of fire increased. However, it is so difficult for victims of fire cases to take proper action. So, this study is to help victims of fire cases in the disputes and compensation claims of the victims, and to find actual and practical support system based on the analysis of compensation status. To help victims of fire cases, we need to survey about victims of fire cases with multiple victims. That survey is analyzed to find support plan for victims. Furthermore, to find support plan the current law is needed to be analyzed and reviewed to revision. It is also tried to identify problems in the operation of the Center for victims of Fire currently operated by fire stations and to find countermeasures. In addition, the status of subscription and problem of fire insurance for the compensation for the victims and the method to increase fire insurance subscription rate will be studied.