A Study on the Energy Saving and Electric Fire Prevention was Caused by with Interception of Standby Electric Power (대기전력차단으로 인한 에너지절약과 전기화재예방에 관한 연구)

  • Kim, Man-Gun;Lim, Seong-Jin;Lee, Chang-Woo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.66-73
    • /
    • 2008
  • In this research, the electric power consumptions of the electrical machinery and appliances selected in the Seoul division of Korea Electrical Safety Corporation were measured. The power-saving efficiency was investigated by comparing the amounts of the reserved electric power when the Saver was on or off through measuring that of the reserved electric power before and after equipping the selected appliances with the Saver, a cutoff of the reserved electric power. As a result, the power-saving efficiency was around 18% when the Saver was installed. It can be ascribed to the removal of the source wasting electrical energy. Furthermore, by blocking the reserved electric power, the electric fire can be originally prevented and also the life time of the electrical machinery and appliances can be postponed.

  • PDF

Characteristics of a Corona between a Wiring Clamp (Dead End Clamp) and a Porcelain Insulator Used in a 154kV Power Receptacle

  • Han, Woon-Ki
    • International Journal of Safety
    • /
    • v.7 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • The occurrence of a corona is that electrical discharge due to the heterogeneity that occurs when an electrical field is concentrated in an electrode due to a cusp formed on said electrode. Wire treatment at the end of a 154kV dead end clamp for end users accelerates the occurrence of corona, which in turn leads to power loss and noise. In this study, the characteristics of the corona which occurs between porcelain insulators and support clamps of overhead lines used in l54kV power receiving facilities for end users were investigated. The corona, which cannot be identified by one common method, was measured utilizing a UV image camera. A risk assessment for fire damage and its status was suggested. The stress distribution of the electrical field by length of bare wire was suggested by means of the finite element method (FEMLAB). As a result, it was found to affect a porcelain insulators. These results can be utilized for the enhancement of clamp installation and safety in power facilities.

Temperature Characteristics on Cooking Equipment Materials of Portable Gas Ranges (이동식부탄연소기의 조리기구재질에 따른 온도 특성)

  • Kim, Dae-Hyun;Lee, Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.8-13
    • /
    • 2014
  • Accidents involving portable ranges occurred total 133 cases for the last five years(2008~2012). It accounted for 18.0% of all gas accidents(739 cases). Major causes of accidents are using of excessive hot grill, leaving a butane can near fire and overheating of a butane can during cooking. In this study, it is a desire to investigate the relationship between thermal behavior mechanism depending on characteristics of cooking equipment materials of portable gas ranges. It shows that slope of temperature change curve correlates with difference of heat capacity on thermal behavior characteristics experiment depending on materials of cooking equipment. In conclusion, temperature characteristics appear differently depending on variables such as materials of cooking equipment. Especially, it is necessary to restrict using cooking equipment made of stones, because it is very dangerous that temperature of can is rapidly increasing caused by high heat capacity of stone.

Evaluation of Occupational Exposure to Noise and Heat stress in Coal-fired Power Plants (석탄화력발전소 작업자의 소음과 온열 스트레스에 대한 노출 평가)

  • Jiwoon Kwon;Kwang-Myong Jang;Sungho Kim;Se-Dong Kim;Miyeon Jang;Jiwon Ro;Seunghyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.464-470
    • /
    • 2023
  • Objectives: This study evaluated occupational exposures to noise and heat stress during routine non-outage works in three coal-fired power plants in the Republic of Korea. Methods: The data were collected during the summer of 2020. Full shift noise exposure of 52 workers were measured using noise dosimeters. Heat stress of 16 worksites were measured for 70 minutes using wet-bulb globe temperature monitors. Results: The noise dosimetry results revealed time-weighted averages that ranged from 47.5 to 88.9 dBA. 2 out of 52 noise measurements exceeded 85 dBA. Based on the arithmetic mean, the coal service group showed the highest level at 80.2 dBA by job tasks. Noise exposures exceeding 85 dBA were measured in the coal service and plant operator group. Heat stress index measurements ranged from 20.3℃ to 37.2℃. 1 out of 9 indices measured in coal facilities and 4 out of 7 indices measured in boiler house exceeded 1 hour TWA during moderate work. Heat stress indices measured from boiler houses were significantly higher than those measured from coal equipment. Conclusions: The results show that overexposure to noise and heat stress may be encountered during routine non-outage work activities in coal-fired power plants. Appropriate actions should be taken to reduce future health outcome from occupational exposure to noise and heat stress in the industry.

Safety and antifatigue effect of Korean Red Ginseng: a randomized, double-blind, and placebo-controlled clinical trial

  • Zhang, Li;Chen, Xiaoyun;Cheng, Yanqi;Chen, Qilong;Tan, Hongsheng;Son, Dongwook;Chang, Dongpill;Bian, Zhaoxiang;Fang, Hong;Xu, Hongxi
    • Journal of Ginseng Research
    • /
    • v.43 no.4
    • /
    • pp.676-683
    • /
    • 2019
  • Background: Korean Red Ginseng (KRG) is widely used for strengthening the immune system and fighting fatigue, especially in people with deficiency syndrome. However, there is concern that the long-term application or a high dose of KRG can cause "fireness" (上火 in Chinese) because of its "dryness" (燥性 in Chinese). The aim of this study was to assess the safety and efficacy of a 4-week treatment with KRG in participants with deficiency syndrome. Methods: This was a 4-week, randomized, double-blind, placebo-controlled clinical trial. A total of 180 Chinese participants were randomly allocated to three groups: placebo control group, participants were given a placebo, 3.6 g/d; KRG 1.8 g and 3.6 g groups. The primary outcomes were the changes in fireness and safety evaluation (adverse events, laboratory tests, and electrocardiogram). The secondary outcomes were the efficacy of KRG on fatigue, which include the following: traditional Chinese medicine (TCM) symptom scale and fatigue self-assessment scale. Results: Of the 180 patients, 174 completed the full study. After 4 weeks of KRG treatment, the Fire-heat symptoms score including Excess fire-heat score and Deficient fire-heat score showed no significant change as compared with placebo treatment, and no clinically significant changes in any safety parameter were observed. Based on the TCM syndrome score and fatigue self-assessment score, TCM symptoms and fatigue were greatly improved after treatment with KRG, which showed a dose- and time-dependent effect. The total effective rate was also significantly increased in the KRG groups. Conclusion: Our study revealed that KRG has a potent antifatigue effect without significant adverse effects in people with deficiency syndrome. Although a larger sample size and longer treatment may be required for a more definite conclusion, this clinical trial is the first to disprove the common conception of "fireness" related to KRG.

A Trends Analysis on Safety for CNG/HCNG Complex Fueling Station (CNG/HCNG 복합충전소의 안전에 관한 동향분석)

  • Lee, Seung-Hyun;Kang, Seung-Kyu;Sung, Jong-Gyu;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • In this research, the safety trends and technologies of HCNG, a mixture of hydrogen and natural gas, are analyzed. This is an attracting alternative fuels to meet the strengthened automotive exhaust gas emission standards. HCNG is very important opportunities and challenges in that it is available the existing CNG infrastructures, meets the strengthened emission standards, and the technical, social bridge of the coming era of hydrogen. It is essential for the commercialization of HCNG that hydrogen - compressed natural gas blended fuel for use in preparation of various safety considerations included accidents scenario, safety distance, hydrogen attack, ignition sources and fire detectors are examined. Risk assessments also are suggested as one of permission procedure for HCNG filling station.

Evaluation to Collision Safety Performance of Stacking Angle Different CFRP/Al Circular Member (적층각이 다른 CFRP/Al 혼성 원형부재의 충돌안전성능 평가)

  • Yang, Yong Jun;Kim, Young Nam;Cha, Cheon Seok;Jung, Jong An;Yang, In Young
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.1-6
    • /
    • 2015
  • The actual condition is that environmental pollution due to the development of various industries has recently become a serious issue. An interest in improving the gas mileage is rising due to an increase in the number of vehicles in the era of high oil price in particular. In order to solve this problem, priority should be given to light-weight design of car body, However, at present, a design method enabling the conventional steel plate to be replaced is direly needed in order to guarantee passengers' safety according to excessive light-weight design of car body. In this study, in order to apply a design method that could realize fuel savings and environmental pollution prevention through an improvement in gas mileage together with meeting the safety requirements for vehicles, it was supposed that CFRP/Al composites member would be used as primary structural member. And to this end, it was intended to obtain optimum design data by experimentally implementing external impulsive load applied to the car body. According to results of impact test of CFRP/Al composites member, a collapsed shape of folding, crack, and bending occurred. So, it was possible to find that energy was observed. And in case of specimen having an angle of $90^{\circ}$ in the outermost layer and stack sequence of $[90^{\circ}{_2}/0^{\circ}2]s$, its collapsed length was shown to be short. Therefore, it was possible to find that the absorbed energy was shown to be higher by 20% or above at the maximum.

Development of Performance Verification Method for Components of IoT-based Industrial Valve Safety Management System (IoT 기반 산업용 밸브 안전관리 시스템 구성장치의 성능검증 방안 개발)

  • Kim, Jae-Ok;Lyu, Geun-Jun;Lee, Kyung-Sik;Kim, Jung-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.10-19
    • /
    • 2020
  • Valve leak accidents in petrochemistry plants and gas utilities cause human and property damage. The main reason why happen gas inhalation, poisoning, fire and explosion accidents is gas valve leakage. To prevent gas leakage, inspectors check the facilities in the field. And they are at risk of gas leak accidents. So we applied IoT-based risk assessment, monitoring and automatic control system. It can detect both internal and external gas leakage, do real-time monitoring of industrial valve in the plant by using hybrid sensor. As the new safety management system for industrial valve is developed, it needs method to evaluate device performance and environmental components for the system. This study is about development of method to verify performance of the explosion-proofed hybrid sensing system include gas detector and optical fiber sensor supporting wire and wireless communication.

Effects of the Safety and Health Management System on the Performance of the Enterprise: Focus on the Electric Power Corporation (안전보건경영시스템의 운영방침이 기업성과에 미치는 영향: 전기공사업을 중심으로)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.135-145
    • /
    • 2020
  • This research is mainly aimed at finding out about the effects of the safety and health management system on corporate performance through systematic operation by efficiently allocating material and human resources within the company by participating all employees and stakeholders in order to prevent and maintain industrial accidents and the optimal working environment, and how to maintain and activate the safety and health management system at the center of electric contractors.The analysis results are as follows. First, management, organizational management and resource preparation will have a positive impact on the management capability of the electric power corporation. It was assessed that the more well-transmitted and understood within the organization, the better the construction plan, the better the equipment management status, the more positively the management capability of electric works was to be achieved. Second, management, organizational management and resource preparation will have a positive impact on corporate management performance.This seems to have a positive effect on a company's business performance when the standards of OHSAS are met with construction plan and construction equipment management are high as related information such as industrial safety and health laws are strengthened and companies' safety and health activities, advanced safety and culture are released to facilitate organizational management.Third, the management ability of the electric power corporation will have a mediated effect on the effect of management, organization management and resource preparation on the performance of the enterprise. This means that the direct effect of the independent variable management organization on corporate management performance is .401 The indirect effect is .168.658 shows that the direct effect of resource preparation on corporate management performance is .423, the indirect effect is .178 and the total effect.It was analyzed at 643.

A Study on the Estimation of Human Damage Caused by the LP Gas Flame in Enclosure using Probit Model

  • Leem, Sa-Hwan;Huh, Yong-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.43-48
    • /
    • 2009
  • The energetic and environmental problems have been getting serious after the revolution of modern industry. Therefore, demand of gas as an eco-friendly energy source is increasing. With the demand of gas, the use of gas is also increased, so injury and loss of life by the fire have been increasing every year. Hence the influence on flame caused by Vapor Cloud Explosion in enclosure of experimental booth was calculated by using the API regulations. And the accident damage was estimated by applying the influence on the adjacent structures and people into the PROBIT model. According to the probit analysis, the spot which is 5meter away from the flame has nearly 100% of the damage probability by the first-degree burn, 27.8% of the damage probability by the second-degree burn and 14.5% of the death probability by the fire.

  • PDF