• Title/Summary/Keyword: Fire safety corporation

Search Result 134, Processing Time 0.022 seconds

A Study on the Ignition Hazards of Flammable Mixtures by Radio Frequency Radiation (고주파 방사에 의한 가연성가스의 점화 위험성 고찰)

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1749-1751
    • /
    • 1998
  • Close to high power radio/radar transmitters there is a possibility that sparks may be occur at discontinuities in metallic structures. If these structures are in an area in which a flammable mixture may be present, there is a possibility that a fire or explosion may be caused by the sparking. A number of assessment procedures for quantification of the hazard have been produced. This paper reviews the bases of the British Standard covering ignition hazards by radio-frequency radiation and presents some ignition test apparatus to access these hazards.

  • PDF

The Orientation Comparison of the Primary and Secondary Beads Grain by EBSD (EBSD를 이용한 1, 2차 용융흔 결정립의 방위 비교 분석)

  • Park, Kwang-Muk;Bang, Sun-Bae;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.11
    • /
    • pp.728-733
    • /
    • 2017
  • Herein, for the quantitative analysis of the arc beads related to electric fire, we used electron backscatter diffraction (EBSD), a measuring device for grain orientation of materials, we compared and analyzed the surface texture of primary and secondary beads according to the difference in cooling rate at ambient temperature. This analysis revealed that the primary beads showed similar distribution at both low and high angles, while the secondary beads showed a higher distribution at low angles than at high angles. Thus, EBSD can be used for quantitative analysis of the beads and can be applied to identify beads in the future.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Reasonable Operation Method for Electrical Safety Management Agency System (전기안전관리대행 제도의 합리적 운영 방안)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Kim, Sun-Gu;Hwang, Kwang-Su;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.14-19
    • /
    • 2012
  • This study proposes to suggest a direction hereafter which is the most suitable operating system of electrical safety management agency for electrical facilities to enhance electrical safety considering our domestic conditions. It was designed to prevent electrical disasters which are increasing due to environmental changes in the electrical industry, and the diversification and complication of the electrical facilities. And the strategy of this research is based on conditions of safety management agency for the electrical facilities, with the analysis on conditions of electrical disasters, and with a questionnaire investigation for owner of electrical facilities, safety management agency. Results of this research are expected to be used to prevent electric fires and shocks effectively by reinforcing the electrical safety management agency of electrical facilities having danger of large-scaled accidents. It is expected to enhance the nation's competing power against foreign countries by reducing the human and physical loss, resulted from the development of reasonable operating system for electrical safety management agency.

The Electromagnetic Shield Properties of 600V class Low Voltage Cable Using Carbon Fiber (탄소섬유를 이용한 600V 이하 저압 케이블의 전자파 차폐특성)

  • Kim, Young-Seok;Kim, Taek-Hee;Kim, Chong-Min;Shong, Kil-Mok;Kim, Ji-Yeon;Kim, Won-Seok;Kwag, Dong-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.243-248
    • /
    • 2017
  • This study used general carbon fibers(CF), which can be utilized for a low voltage cable screen, as well as metal-coated carbon fibers(MCF) to make cables and analyzed the properties of electromagnetic effectiveness. Both braid CF and MCF cables with 3,000 strands, 16 spindles, and braid density of 90% or over were adopted. The tape-type MCF specimens were spread into a tape(width: 15mm) using a hot melt to make a cable. The shield effectiveness was measured up to the 1GHz range in accordance with IEC 62153-4-6; braid shielded cables featured a superior shielding effect at 63dB than tape-type shielded cables. That was because the tape-type shielded cable has relatively more gaps and holes between carbon fibers than the braid type, resulting in a more inflow or emission of electromagnetic waves. In the case of braid cables, the characteristics of their electromagnetic waves were enhanced, with higher spindles and higher conductivity of carbon fibers. The shield effectiveness of the MCF shielded cable, however, was lower than that of tin-coated one.

Comprehensive Countermeasure for Safety of School Electric Installation (학교 전기설비의 안전을 위한 방안)

  • Jeon, Jun-Man;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.65-66
    • /
    • 2006
  • The speciality of education installation has to be applied to the design construction, inspection of school in the installation. But. it was applied general electric installation standards in korea. Therefore, the electric shock accidents and fire was more frequently occurred in the school than in other building. So, this paper, is proposed the comprehensive countermeasure for safety of school electric installation

  • PDF

A Study on the Consequences of Underground High Pressure Natural Gas Pipelines (고압 매몰 천연가스 배관 누출사고 피해해석에 관한 연구)

  • Lee, Seungkuk;Shin, Hun Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.2
    • /
    • pp.44-49
    • /
    • 2013
  • Due to rapid rise of consuming rate for natural gas, installation and operation of high pressure natural gas pipeline is inevitable for high rate of gas transportation. Accordingly incidents on the underground high pressure natural gas pipeline come from various reasons will lead to massive release of natural gas and gas dispersion in the air. Further, fire and explosion from ignition of released gas may cause large damage. This study is for release rate, dispersion and flash fire of natural gas to establish a safety management system, setting emergency plan and safety distance.

A Study on Mitigating Accidents for Liquid Hydrogen (액체수소 사고피해 완화기술에 대한 연구)

  • Jo, Young-Do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.29-33
    • /
    • 2012
  • This paper is an attempt to give a concise overview of the state-of-the-art in the recent liquid hydrogen safety researches with unwanted event progress. The vessel of liquified hydrogen may fail and liquid hydrogen spilled. The hydrogen will immediately start to evaporate above a pool and make a hydrogen cloud. The cloud will disperse and can produce a vapor cloud explosion. The vessel containing the liquid hydrogen may not be able to cope with the boil-off due to heat influx, especially in case of a fire, and a BLEVE may occur. In equipment where it exists as compressed gas, a leak generates a jet of gas that can self-ignite immediately or after a short delay and produce a jet flame, or in case it ignites at a source a certain distance from the leak (delayed ignition), a flash fire occurs in the open and with confinement a deflagration or even detonation may develop. The up-to-date knowledge in these events, recent progress and future research are discussed in brief.

A Study on the Delayed Factors in Evacuation Behavior in the Case of Fire Accidents in Highway Tunnels (고속도로 터널 내 화재사고 발생 시 대피행동 지연 요인에 관한 연구)

  • Jae-Hwan, Cho
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.4
    • /
    • pp.143-148
    • /
    • 2022
  • This paper attempted to analyze the correlation between the risk image of the evacuees in the tunnel and the variables that affect the evacuation behavior due to the closed feeling. As to whether there is a difference in the level of recognizing the tunnel risk image according to the distribution of jobs, the null hypothesis was rejected at the significance probability of 0.002, so it can be said that the level of recognition of the tunnel risk image varies depending on the job group. In the distribution difference between gender and tunnel risk image recognition level, the significance probability was 0.012, indicating that the null hypothesis was rejected, indicating that the tunnel risk recognition distribution according to gender was different. As a result of analyzing the distribution difference between the tunnel's closed feeling and the tunnel risk perception level, the significance probability was 0.001, and the null hypothesis was rejected, indicating that there was a difference in the tunnel risk image level.

A Study on Seismic Design Method Considering Physical Properties of Piping Material (배관 재료의 물성을 고려한 내진설계 방법에 관한 연구)

  • Bang, Dae-Suk;Lee, Jae-Ou
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.38-47
    • /
    • 2018
  • In this study, we compare the engineering seismic design method considering the physical properties of piping materials and the specification-oriented design method according to the seismic design standards of fire fighting equipment. In the case of the seismic design method considering the physical properties of piping materials, the safety of the piping will be analyzed through the combined value of the torsional stress and the bending stress generated in the piping. However, in the case of the design-centered design method, instead of the safety of the piping material, it calculates the moving force of the pipe and interprets whether or not the shaking prevention strut can bear. Fire extinguishing equipment piping is possible through safety analysis of stress and displacement of piping material because piping safety can not be secured via unstable force generated in a certain section with one connected structure is there. Therefore, it is necessary to apply analytical method considering seismic performance of building structure and material properties of piping for seismic design of safe fire extinguishing system piping.