• Title/Summary/Keyword: Fire safety corporation

Search Result 134, Processing Time 0.028 seconds

The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage (저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석)

  • Kim, Dong-Woo;Kim, Hyang-Kon;Gil, Hyung-Jun;Han, Woon-Ki;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF

Development of the Fire Prevention Method related to Gas in the Area of Dense Energy Consumption (에너지 사용 밀집지역에서의 가스 관련 화재예방 기법 개발)

  • Kim, Jung-Hoon;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.29-33
    • /
    • 2018
  • Accident likelihood is growing due to a correlation for gas and electricity installed in the area of dense energy consumption like traditional market and underground shopping center. In order to prevent and respond accident risks related to gas and electricity in this area, it should be monitored and predicted for factors of gas leak or electricity by developing safety management system. This study is about accident prediction model development considering fire risk factor related to gas accident. The temperature variation characteristic near a gas burner was analyzed. Also, accident prediction algorithm and related module were developed to prevent fire in the area of dense energy consumption.

A Simulation of Electric Fire in Power Panel (분전반 내부 전기화재 시뮬레이션)

  • Lee, Sang-Ick;Kim, Gi-Hyun;Shin, Sung-Su;Bae, Suk-Myeong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2150-2151
    • /
    • 2011
  • 본 논문에서는 분전반 내에서 전기화재가 발생할 경우 화염전파와 연기화염의 전파 특성, 연기의 진행방향, CO가스농도의 위치, 내부 온도분포 등을 통해 전기화재의 사전예방과 화재대응 운영시스템 등에 활용하고자 수치해석 등의 시뮬레이션을 수행하였다. 시뮬레이션 결과 화재가 발생한 경우 온도보다 CO가스가 분전반 상부에 빠르게 전달됨을 확인하였고, 시뮬레이션 결과는 분전반 화재예방을 위한 센서의 선택과 설치위치 선정 등에 활용될 것이다.

  • PDF

A Study on Electrical Accident of Distributing Cable Termination with Simulated Badness Construction (평가시공불량을 모의한 배전급 케이블 종단부의 전기적 사고 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun;Kim, Young-Seok;Kim, Sun-Gu;Baek, Seung-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.465-470
    • /
    • 2008
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated badness construction. We prepared two termination kites, one is built-up type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and measured their insulation characteristics such as ac (35kV, 1min) and impulse (95kV, $1.2{\times}50{\mu}s$) withstand test. The influence of defects such as thickness and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness decrease of insulator decreases ac breakdown strength. Dielectric breakdown traces of insulator that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of insulator seriously.

  • PDF

An Evaluation on Electrical Shock and Ignition Hazards in Metallic Structures Acting Receiving Antennas of Radio-frequency Radiation (고주파 방사에 대한 수신 안테나로 작용하는 구조물에서의 전격 및 점화 위험성 평가)

  • Choi, Sang-Won;Lee, Hyung-Soo;Lee, Gwan-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2280-2283
    • /
    • 1999
  • Close to high power radio/radar transmitters, there is a possibility that electrical sparks may occur at discontinuities in metallic structures. If these structures are in an area where flammable mixtures are present, there is a danger that fire or explosion may happen by these sparks. Voltage may be induced on these metallic structures by the radio-frequency transmitter. In this case, a person who comes into contact with these structure may be undergone a severe electrical shock. In this paper, assessment of the these hazards was investigated through experimental and evaluation for actual tower cranes near AM radio transmitters.

  • PDF

A Development of Consequence Analysis System for Combustible Materials Release Events Based on HTML5 Web (HTML5 웹 기반 가연성 물질 누출 피해영향평가 시스템 개발)

  • Lee, Ugwiyeon;Ji, Hyunmin;Oh, Jeongseok;Cho, Wansu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.39-60
    • /
    • 2019
  • Korea Gas Safety Corporation is developing consequence analysis system for combustible materials release events to enhance risk assessment technology and its efficiency. Unlike general consequence analysis programs, the final consequence area was implemented through ETA analysis based on API-581 standard, and a convenient user interface was constructed based on HTML5-based responsive web technology. In addition, a phase equilibrium module using third-order state equations (such as Peng-Robinson, SRK, and RK) and fugecity was implemented to analyze the mixture quality. Also. using the consequence analysis algorithm introduced in CCPS books and TNO Yellow Book, we developed material leak analysis module, fireball, pool fire, jet fire, flash fire, and vapor cloud explosion consequence assessment module. In addition, the conditions for calculating the safety distance were prepared with using the control values in the EIGA standard, PAC, and Bevi Reference Book.

Deterioration Character of tunnel damaged by fire and Fire Proofing Measure (화재에 의한 터널 열화특성 및 내화대책 기술)

  • Seo, Kang-Chun;Yoon, Tae-Gook;Park, Si-Hyun;Cho, Sung-Han;Kim, Eun-Chong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.129-139
    • /
    • 2005
  • In this paper, the behaviors of tunnel damaged by fire, the diagnostic techniques for evaluating tunnel stability are presented. Also two fireproof construction methods are recommended. Three tunnels damaged by fire were analyzed to evaluate the structural stability. From the these analyzed, it is recommended that surface checking, rebound number of concrete by Schmidt Hammer, and carbonation of concrete are essential to evaluate the engineering properties of concrete in tunnel structure damaged by fire. On the basis of case studies of tunnel fire collected by ITA, the change of concrete and steel strengths by fire are explained, and numerical analysis, which was performed on culvert and circle tunnel, shows that distribution of temperature in the tunnel is dependant upon tunnel shape. Two fireproof construction methods using panel and punching metal are introduced to protect the tunnel by fire.

  • PDF

Study on the Promotion of Recycling of Old Fire Extinguishers (폐 소화기 재활용 촉진 방안에 관한 연구)

  • Jin, Young-Bae;Jung, Myung-won;Oh, Jung-Seok
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.156-163
    • /
    • 2019
  • This study examined the recycling system of a foreign lung excreta system. First, the measures for promoting the recycling of a pulmonary digestive system were as follows. Second, a manual considering specialization, such as the construction of a recycling treatment system of fire extinguishers and the collection, transportation, recycling, publicity, and education of fire extinguishers, were developed. Third, an education and counseling system is needed to overcome the lack of experience and technical support for systematic and safe disposal of pulmonary digestive system. Fourth, to promote the recycling of fire extinguishers in the government and fire extinguisher related organizations, it is necessary to prevent environmental pollution and recycle parts to reduce the waste of resources and improve the fire extinguisher quality by fostering a fire safety industry and policy support.

Study on the Effect of Life Safety Awareness and Safety Behaviors of Fire Professional Engineers on Life Safety (소방기술사의 안전의식, 안전행동과 인명안전과의 관계 연구)

  • Kim, Myung-Cheol;Ko, Han-Mog;Park, Jae-Kwan;Seo, Hae-Yeol;Yu, Byoung-Sun;Yoo, Chang-Bum;Youn, Hae-Kwon;Joo, Seung-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.112-121
    • /
    • 2018
  • In the present study, a group of subjects consisting of "Fire Professional Engineers" was selected to examine the effects of life safety awareness and safety behaviors of the subjects on life safety through an analyses of the descriptive statistics, factors, reliability, and correlation; simple regression and three-stage regression analyses on mediation were also carried out based on the hypotheses developed. The results showed that the degree of safety behavior increased by 72.1% in accordance with the increased safety awareness of fire professional engineers; the life safety was also increased by 61.5% and 64.5% by the increases in safety awareness and safety behavior of fire professional engineers, respectively. In addition, the safety behaviors demonstrated a partial mediatory effect in the relationship between safety awareness and life safety. All hypotheses (H1, H2, H3, H4), established for the present study, were accepted based on statistical verifications that justified an amendment of the Acts pertinent to firefighting service focusing on life safety; the data are expected to be exploited to reflect significance of life safety.