• Title/Summary/Keyword: Fire safety awareness

Search Result 104, Processing Time 0.024 seconds

A Survey Study on the Usage and Situation of Indoor Fire Hydrants (옥내소화전의 사용실태 및 현황에 관한 연구)

  • Lee, Wonjoo;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.141-146
    • /
    • 2016
  • The purpose of this paper is to investigate the basic data (e.g. education experience and awareness of the installation situation, and usage of indoor fire hydrants) for the effective planning, progress and improvement of fire safety education. For this purpose, we surveyed 198 participants and an analysis of the frequency and descriptive statistics based on the survey data was carried out using SPSS 20.0 for Windows. The analysis results showed that 87.9% of the research participants live in accommodation with indoor fire hydrants installed and that, among them, 17.7%, did not know their location. 63.6% of the research participants, had received fire safety education but, among them, 31.0% had never been educated about the use of indoor fire hydrants. The main type of fire education was instructor-led training, which represented 50.0% of the participants. We believe that the results of this paper will serve as a basis for efficient adult fire safety education.

A Study on the Development Plan for Promotion of Advanced Disaster-Safety Awareness (선진 재난안전의식의 활성화를 위한 방안 연구)

  • Lee, Jong-hyun;Kim, Mi-ra;Ko, Jae-chul
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.415-426
    • /
    • 2021
  • Purpose: The purpose of this study is to create the deveopment plan for promotion of advanced disaster-safety awareness, which is noted as a major factor in the large disaster. Method: This study is to conduct theoretical review with regard to disaster management and safety awareness. Consciousness surveys on safety awareness and previous disaster case was analyzed to derive the cause of the disaster, and the development plan for promotion of advanced disaster-safety awareness was suggested. Result: In the survey on the public's sense of safety on the disaster management evaluation, 'Response' stage was well performed, but the 'Recovery' stage was not. Especially, it was found that disaster safety education at the 'Prevention' stage was very lacking. In the survey on the public's safety awareness, the awareness level of the evacuation facility was very low, information on infectious diseases and collapse accident was insufficient. Especially, it has been found that the awareness on safety regulation in daily life is very insufficient. Through the case study on previous disaster(COVID-19, Fire in Miryang Sejong Hospital, Forest fire in the east coas at 2004'), it was derived that the lack of safety awareness(such as safety insensitivity) was the main factor of the expansion of the damage scale. Conclusion: The development plan for promotion of advanced disaster-safety awareness are as follow. First, it is necessary to spread the safety culture movement through the expansion of safety education and safety promotion. Second, disaster confrontation training for the public should be implemented to improve the effectiveness of disaster response. Finally, it is necessary to change the individual awareness on safety. When these factors are implemented systematically, advanced disaster-safety awareness can be promoted. Ultimately, disaster accidents in our society can be reduced.

Awareness on middle and high school teachers for fire safety education (소방안전교육에 대한 중·고등학교 교사들의 인식)

  • Hong, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.586-593
    • /
    • 2019
  • The purpose of this study is to investigate the perception of fire safety education in middle and high school teachers. The results of this study provide basic data necessary for future school safety education. The research was carried out using a questionnaire given to 317 school teachers. The frequency of the questionnaire was calculated from frequency analysis using SPSS version 19.0. A chi-square test was conducted to verify the analyzed questionnaire data. Cronbach's alpha for fire safety awareness in the respondents is 0.845, which is very reliable. According to the results of the survey, fire safety education currently conducted in schools is aimed at having a safe lifestyle and respect for life. The training is conducted once every six months, on average, and training time is 30 to 45 minutes. Fire safety education in schools is conducted in the form of experience-oriented education in cooperation with fire-related organizations following the plan of the school. Educational texts are used and utilized through the Internet and in related publications. Under the present circumstances, it is necessary to secure sufficient space to run an experience-related education program and to actively participate in the students' fire safety education at the school.

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.

Study on the Ship Fire Analysis According to Explosion Hazard (폭발의 위험성에 의한 선박화재의 사고사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • This study analyzed recent cases of ship fires explosions and investigated their problems and coping plans. Through analysis on the statistical figures, it was found that our nation's situations of maritime accidents by kind during the period of 2009~2013 showed the ratios of ship accidents caused by fires explosions was the highest in 2012 with 7.58% (55 cases) followed by year 2009 with 3.39% (34 cases), year 2010 with 3.39% (25 cases), year 2011 with 6.03% (57 cases) and year 2013 with 6.74% (43 cases), which indicates a steady increase in the number of ship accidents. Majority of reasons for ship fires explosions were lack of safety awareness. Since those accidents happen on the sea, fires, once they happen, tend to get serious due to absence of on board & nearby fire extinguishing facilities, public fire service's uneasy access to them and great influences of natural factors such as wind and etc. Ship fires explosions are special cases unlike what happens to general edifices. So, their coping plans should focus on preventive measures since the damages those cases bring about can be detrimental. For this reason, it's necessary to research precise evacuation plans, develop ship structure & materials reinforcing fire resistance to secure more time for evacuation and enhance people's safety awareness by implementing thorough safety training.

A Study on the fire safety guide for notifying how to cope with the fire in the subway. - Focus on TOKYO BOUSAI safety guide in Japan - (지하철 화재 안전 가이드 방안 연구 - 일본의 도쿄방재 안전 가이드를 중심으로 -)

  • Park, Mi-Seon;Kim, Seung-In
    • Journal of Communication Design
    • /
    • v.57
    • /
    • pp.398-407
    • /
    • 2016
  • This thesis is about how to let people be aware of the importance to raise awareness of the safety by offering User-center guide line instead of staff-center guide line. That's why it is important to make clear and be aware of how to prevent and how to cope with accident because it can lead to casualties which might be a tragic. For all that the guide for the fire accident is posted on the web site of each metro administration without any standard of information or coherence. Therefore it is urgent to make and provide new User-center guideline and to make it better we need to keep the following principles. First of all, the principles of Universal design should be applied to all the User-center guide line for fire accident at the subway station based on the comprehension of public design. Secondly, every metro administration need more communication to organize one coherence in designing instead of unilateral advertisement. Lastly, campaigns and training should be expanded in everyday life, so the citizen can raise awareness of the accident by themselves.

A Study on The Safety Awareness of Technical High School Student in Chemistry Major (화학전공 특성화 고등학생의 안전의식에 관한 연구)

  • Hong, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.617-625
    • /
    • 2020
  • The purpose of this study was to elucidate the safety consciousness of high school students in chemistry-related departments in terms of disaster safety education, degree of safety education knowledge, and the relationship between safety consciousness and safety education knowledge. The subjects were 469 students attending technical high schools in Gyeonggi and Chungcheongnam-do. For the results, students responded that their level of safety consciousness (3.44) was better than that of others (2.85). In addition, safety regulations were considered in relation to others. Safety education at school was cited as necessary, but respondents were not interested in the education contents. Students had been receiving safety education at school, but they cited that the use of protective equipment in class was not performed well. Disaster awareness was positively (+) correlated, and safety and fire safety awareness were found to be significant. The results of this study can be used as basic data for safety education to improve disaster safety education. It is necessary to develop an education program to raise safety awareness and to develop an education manual. Based on this study, future studies should be conducted.

A Study on Real Condition Estimation for Fire Protection Safety Management System Builds (소방안전경영시스템 구축을 위한 실태평가에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.18-24
    • /
    • 2013
  • Goverment and enterprises have been devoting a lot of dffort in order to prevent the loss of human and property due to a large, diversified fire, explosion, global warming and disasters caused by natural phenomena. But Enterprises came forward and running in the economy priority policy for profit-seeking until now in order to meet the macro purpose of quality improvement of national life and welfare promotion in company with National growth, as a result of lax risk management have had to endure the loss of precious lives and property. According to the '2007 Survey of public safety for the activation of the safety culture' of National Emergency Management Agency [NEMA], a insensitivity of safety in our society was surveyed 'a serious level'. In this study, surveyed need of 'step-by-step fire protection safety management system builds' in order to prevent fire safety accident and improvement of safety awareness level through a systematic management and real condition estimation of not only large business that can control risk management, but also small business that has a big risk to occur accident easily according to small budget and organization.

Research on the Current Status of Installation and Awareness of Fire Extinguishers and Awareness of Fire Extinguishers (일상생활 환경에서의 소화기 비치 실태와 소화기 인식에 관한 연구)

  • Lee, Wonjoo;Kwon, Shin Young;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.26-32
    • /
    • 2015
  • The main purpose of this study is to propose a directionfor fire safety education and to discuss the current issues of fire extinguisher training A survey was conducted, and the results show that only 52.1% of homes have a fire extinguisher, whereas over 93% of public and private work places (e.g., schools and businesses) have a fire extinguisher. Approximately 90% of the survey participants had fire extinguisher training experience. However, only 65.8% of the public and private work places conducted fire extinguisher training regularly. 42.5% of survey participants had not been trained in the past year. In the survey result on fire extinguisher knowledge, participants showed a score of 3.95/5.00 for how to use a fire extinguisher and a score of 3.00/5.00 for the meaning of the ABC ratings of fire extinguishers. An independent T-test showed that the "the installation of fire extinguishers in the house" and "regular fire safety education in your group" have influences on the "the knowledge of fire extinguishers" (p < .05).

A Study on the Analysis of Welfare Awareness Level of Paramedics (소방 구급대원의 복지 의식 수준 분석에 관한 연구)

  • Yu-Jin Park;Bong-Kil Kim;Hyun-Mi Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.851-860
    • /
    • 2024
  • This study analyzed factors that influence the welfare awareness level of paramedics. Paramedics are professionals responsible for the health and safety of the public, and their welfare is a factor that enables them to carry out their duties smoothly. The study results showed that the overall level of welfare awareness was analyzed to be very low at 2.80 points. We also found that there were gender and class differences in some areas. One notable point is the item 'In the event of a lawsuit or other complaint or accident during a call, the fire department responds adequately for me.' which received the lowest score of 2.22 point. I hope that in the future, fire departments will implement policy measures to protect emergency personnel from complaints and reduce the stress they experience when dispatched to disaster areas. Based on the results of this study, I hope that follow-up researchers will conduct a comparative analysis of the level of welfare awareness among various factors.