• Title/Summary/Keyword: Fire resistant paint

Search Result 11, Processing Time 0.03 seconds

A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint (방염도료의 방염성능 및 발연특성에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.78-83
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF, to find flame resistance performance and smoking characteristics according to principal ingredient and characteristics of fire resistant paint. 45 degree combustion test and smoke density test were conducted to investigate the flame resistance performance and smoking characteristics. According to the 45 degree combustion test, acrylic resin type fire resistant paint showed the most excellent fire resistance performance. And the water soluble fire resistant paint showed better fire resistance performance compare to the solvent soluble paints. Also gloss paint showed better fire resistance performance than the flat paint. Based on the smoke density test, the smoke generation of fire resistant treated specimen of acrylic resin type was least. And the water soluble fire resistant paint generate little smoke than solvent soluble fire resistant paint.

Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire (표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구)

  • Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.14-18
    • /
    • 2018
  • The earlier studies on the fire resistance performance of woods used as building materials have focused on confirming combustion characteristics of fire retardant or flame resistant treated wood. In this paper, to confirm internal temperature changes closely related to pyrolysis of woods exposed to the flame, heating experiments were conducted in a heating furnace according to the standard heating temperature curves after Douglas-fir, which is widely used as structural materials, was treated with a flame resistant solution and flame retardant paint. As a result of the experiment, it was confirmed that the thermal diffusion inside the wood has decreased when the wood was treated with the flame resistant solution. However, in high temperature, the flame resistant effect could not be expected due to the peeling of the coating in the case of the flame resistant paint treated wood. Therefore, it can be considered that it is more effective to use the flame resistant solution which penetrates in to the inside of the wood than flame resistant paint which forms the coating on the surface of the wood in order to enhance the flame resistance effect on the thick wood.

A Study on the Ignition Delay Effect by Flame-Resistance Paint Treatment (방염 처리에 따른 화재지연 효과 연구)

  • Oh, Kyu-Hyung;Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.111-116
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF(middle density fiber board), which suitable to the regulation of Fire Service Act. And we investigate a ignition delay effect under a exposure condition of radiative heat of fire. Radiative heat flux was controlled from $10kW/m^2$ to $30kW/m^2$ using the cone heater. Ignition time, ignition type and surface temperature of the sample were measured. Based on the experimental result, critical heat flux of the fire resistant paint treated sample was $10kW/m^2$ and there were no ignition delay effect above the $30kW/m^2$. And it was found that it will be difficult to expect the fire resistant effect above $400^{\circ}C$ of sample surface temperature.

Characteristics study on fire-resistant paint used by TGA-IR (TGA-IR을 사용한 내화 도료의 특성에 관한 연구)

  • Cho, Nam-Wook;Shin, Hyun-Jun;Cho, Won-Bo;Lee, Seong-Hun;Rie, Dong-Ho;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.168-172
    • /
    • 2011
  • The iron frame of building could be collapsed or bent at $500^{\circ}C$. Therefore the fire-resistant paint should be applied for safety. This study performed the comparative analysis to show the characteristics of fireresistant paint. And then 12 products of fire resistant paint and 6 products of paints were used as samples. And the samples were analyzed by TGA (Thermogravimetric Analyzer) as analyzer for measuring the variation of weight on temper of weight by heating. When TGA analyzer could measure the variatiature, and FT-IR was measured for analyze gas components on variation on of weight by heating on 12 products of fire resistance, the samples showed to decrease 40% of weight to $800^{\circ}C$, and because paints had 50% to 40% of loss weight, it showed to be equal with loss weight of fire resistance paint on high temperature or was lower loss weight than it of fire resistance paints. However number 6 sample of fire resistance paints could show to decrease 20% of total weight on $800^{\circ}C$. And then in the case of FT-IR, fire resistance paints could show to have the high intensity of $CO_2$ spectrum as complete combustion. However paints could show to have the lower intensity of $CO_2$ spectrum, have the higher intensity of water spectrum. Therefore the TGA graph of result could be much different until $250^{\circ}C$. When it was burned, FT-IR spectrum could show to confirm the characteristics of fire resistance paints, and the characteristic could be confirmed on inorganic paint of fire resistance by weight loss of TGA.

A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer (X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.124-129
    • /
    • 2016
  • According to the current law, on-site flame resistant-treated interior decorations should pass the flame resistant performance test through a 45 degree combustion test from the district fire department. Although a 45 degree combustion test is the most accurate method for determining the flame resistant performance, it can be unreliable when tested on unauthorized samples. To avoid unauthorized sampling, this study suggests on-site flame resistant inspection by X-ray fluorescence spectrometer. Ten types of flame resistant paint were spread on plywoods and MDFs and the components were analyzed by X-ray fluorescence spectrometer. As a result, due to a difference amounts of substances in each paint, each flame resistant paints showed its own characteristic spectrum and the contents of each substance could be determined. On-site flame resistant inspections can be used efficiently when institutional procedures are created.

A Fire Risk Assessment of Substrate for Fire Resistant Painted (난연도료를 도장한 바탕재의 화재 위험성평가)

  • Park Young-Keun;Lee Doo-Hyung;Yoon Myung-O;Hyun Seong-Ho
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.51-58
    • /
    • 2005
  • In this paper, The experimental materials of painted fire resistant paint on substrate, FRP, PVC, AL and stainless steel that fire resistant paint developed newly were evaluated as the hazard elements : the fire resistibility of the materials, fire spread test of flame, the oxygen index, flammability, the smoke density. the toxicity index from it when it burned. As a result of the experiments, the AL and the stainless steel were passed of fire resistant class 1, the FRP, the AL, and the stainless steel were ignited of fire spread test of flame, all the experimental materials showed about $50\%$ of oxygen index, V-0 of flammability, and 43-338 of maximum smoke density at flaming mode used smoke density chamber. Also, they showed that the toxicity index of combustion products were 0.57-1.12.

The fire-risks of cost-optimized steel structures: Fire-resistant and hot-rolled carbon steel

  • Garcia, Harkaitz;Cuadrado, Jesus;Biezma, Maria V.;Calderon, Inigo
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.67-75
    • /
    • 2021
  • This work studies the behaviour of a steel portal frame selection under fire exposure, considering both span lengths and fire exposure times as variables. Such structures combine carbon steel (S275), fireproof micro-alloyed steel (FR), and coatings of intumescent paint with variable thicknesses, improving thereby the flame retardant behaviour of the steel structure. Thus, the main contribution of this study is the optimization of the portal frames by combining both steels, analysing the resulting costs influence on the final dimensions. Besides, the topological optimization of each steel component within the structure is also defined, in accordance with the following variables: weather conditions, span, paint thickness, and cost of steel. The results mainly confirmed that using both FR and S275 grades with intumescent painting is the Pareto optimum when considering performance, feasibility and costs of such portal frames widely used for industrial facilities.

An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure (뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구)

  • Ok, Chi-Yeol;Kim, Jae-Jun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • v.12 no.4
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.