• Title/Summary/Keyword: Fire resistance test

Search Result 391, Processing Time 0.024 seconds

Statistical Analysis of the Structure and Performance of Fire Doors for Evacuation Space and Common Areas in Apartment Housing (공동주택 대피공간·공용부 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.3
    • /
    • pp.239-249
    • /
    • 2022
  • Fire resistance performance and performance design of fire doors are becoming more important to prevent the spread of fire and support the rapid evacuation of apartment buildings. In this study, a database using 182 evacuation spaces and 308 common areas that passed the fire performance test was established, and fire door performance influencing factors were derived through an analysis of the structure(12 elements) of the fire door. As a result, the effects of fire-resisting filler density, adhesive, and foam gasket were confirmed for evacuation space, and the effects of fire-resisting filler, adhesive, and fire fins were confirmed for common areas. In the fire door fire resistance test, flames and cracks were analyzed as the most frequent failure factors.

New Fire Resistant Methods of RC Structures Using ECC (구조물의 내화공법에 대한 ECC 적용 가능성)

  • Kim, Jung-Hee;Chun, Byung-Il;Lee, Myung-Ho;Chung, Jae-Min;Ahn, Sang-Ro
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.961-964
    • /
    • 2008
  • Fire safety is one of the important factors to be examined when applying ECC to actual concrete structures. The purpose of this study is to confirm whether the fire resistance of ECC satisfies the fire resistant requirements in order to use the fire protection material in concrete structures. Employed temperature curve are HC and RABT criterion, which are severe in various criterion of fire temperature in concrete structures. The test results show that ECC did not undergo any deterioration of fire resistance nor cause explosive spalling, which had been anticipated due to the presence of organic fibers. With comparison of current concrete and fire-resistance materials, the experimental results of ECC shows the better fire resistance performance than the other.

  • PDF

Evaluation of Effective Thermal Conductivity and Thermal Resistance in Ground Heat Exchanger Boreholes (지중 열교환기 보어홀에서의 유효 열전도도 및 열저항 산정)

  • Sohn Byong Hu;Shin Hyun-Joon;Park Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.695-703
    • /
    • 2005
  • The objective of this study is to determine the effective thermal conductivity and thermal resistance values in test boreholes with three different fill materials. To evaluate these heat transfer properties, in-situ tests on four vertical boreholes were conducted by adding a monitored amount of heat to water over various test lengths. Two parameter estimation models, line-source and numerical one-dimensional models, for evaluation of thermal response test data were compared when applied on the same four data sets. Results show that the average thermal conductivity deviation between measured data and these two models is in the range of $3.03\%$ to $4.45\%$. The effect of increasing grout thermal conductivity from 1.34 to 1.82 $W/m^{\circ}C$ resulted in overall increases in effective formation thermal conductivity by $11.1\%$ to $51.9\%$ and reductions in borehole thermal resistance by $11.6\%$ to $26.1\%$.

Experimental and Numerical Study of Fire Resistance of Composite Beams (무피복 합성보의 내화성능에 대한 실험 및 해석적 연구)

  • Ahn, Jae Kwon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.143-153
    • /
    • 2015
  • In this paper, the standard fire resistance test under load and associated numerical study were carried out to evaluate the fire resistance of unprotected partially encased beams and slimfloor beams. The temperature evolution and the deflection increase of the composite beam specimens were investigated and the effects of the key behavioral parameters including the load ratio, the reinforcement, and the fire exposure were analyzed. The test results showed that the temperature rise of the partially encased beams and slimfloor beams is considerably slow compared to the conventional H-shape composite beams. Up to at least 90 minutes, the reinforcements in the partially encased composite beams maintained below the temperature at which the cold steel strength is sustained. Unprotected partially encased beams and slimfloor beams in the experimental program achieved the fire resistance more than 2 hours according to the limiting deflection criteria. This implies that unprotected partially encased beams and slimfloor beams can be very promising alternatives to enhancing the fire resistance of steel beams. This study also conducted the fully coupled thermal-stress analysis by using the commercial code ABAQUS to the thermal and structural behaviour of composite beams in fire. The numerical predictions provide acceptable correlations with the experimental results.

A Evaluation of Fire Behavior According to Member Thickness of Precast Prestressed Hollow Core Slab of Fire Resistance Section (프리캐스트 프리스트레스트 내화단면 중공슬래브의 부재두께에 따른 화재거동평가 )

  • Yoon-Seob Boo;Kyu-Woong Bae;Sang-Min Shin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • At construction sites, interest in the production of precast materials is increasing due to off-site conditions due to changes in construction site conditions due to increased labor costs and the Act on the Punishment of Serious Accidents. In particular, the precast prestressed hollow slab has a hollow shape in the cross section, so structural performance is secured by reducing weight and controlling deflection through stranded wires. With the application of structural standards, the urgency of securing fire resistance performance is emerging. In this study, a fire-resistance cross section was developed by reducing the concrete filling rate in the cross section and improving the upper and lower flange shapes by optimizing the hollow shape in the cross section of the slab to have the same or better structural performance and economic efficiency compared to the existing hollow slab. The PC hollow slab to which this was applied was subjected to a two-hour fire resistance test using the cross-sectional thickness as a variable, and as a result of the test, fire resistance performance (load bearing capacity, heat shielding property, flame retardance property) was secured. Based on the experimental results, it is determined that fire resistance modeling can be established through numerical analysis simulation, and prediction of fire resistance analysis is possible according to the change of the cross-sectional shape in the future.

Fire Resistance Performance of Recycling PET Fiber Reinforced High Strength Concrete Circular Column (재생 PET섬유 보강 고강도 콘크리트 원형기둥의 내화성능)

  • Seo, Tae-Seok;Gong, Min-Ho;Kwon, Hae-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.513-518
    • /
    • 2016
  • This study evaluates the fire resistance performance for 60MPa high strength concrete reinforced by recycling polyethylene-terephthalate(PET) fiber(fiber content : 0.05 vol.%). Because there is no fire resistance test results for circular concrete column, a fire resistance test was carried out for circular concrete column specimens. As a result, it was confirmed that PET fiber was effective against the spalling control of high strength concrete. However, the specimen with cover thickness 30mm did not satisfy the temperature standard of main reinforcement, and the specimen with cover thickness 40mm satisfied the temperature standard of main reinforcement. Therefore, more than 40mm cover thickness was demanded for stable fire resistance performance.

The Fire Resistant Performance of the High-Strength Concrete Column Covered with Aerogel Compound Inorganic Blanket and Gypsum board (에어로젤 복합 무기질 블랭킷 및 석고보드 피복 고강도콘크리트 기둥의 내화성능)

  • Yeo, In-Hwan;An, Jae-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.201-203
    • /
    • 2011
  • The purpose of this study was to develop and evaluate of fire resistive cladding systems for HSC(high-strength concrete) column, which was mainly constructed with aerogel blanket insulation material. The aerogel blanket-fire protective gypsum board cladding system showed that it clearly secure the fire resistance performance of HSC column when the reinforcing measures had achieved for four cross-sectional edge sides of structure and the system is well continued during the test period with no significant deformation or separation etc. It was checked out the 20mm thickness cladding system consist with AG(5mm)+FGB(15mm) can secure 3hour-fire resistance performance adequately.

  • PDF

Evaluating fire resistance of prestressed concrete bridge girders

  • Zhang, Gang;Kodur, Venkatesh;Hou, Wei;He, Shuanhai
    • Structural Engineering and Mechanics
    • /
    • v.62 no.6
    • /
    • pp.663-674
    • /
    • 2017
  • This paper presents an approach for evaluating performance of prestressed concrete (PC) bridge girders exposed to fire. A finite element based numerical model for tracing the response of fire exposed T girders is developed in ANSYS. The analysis is carried out in three stages, namely, fire temperature calculation, cross sectional temperature evaluation, and then strength, deformation and effective prestress analysis on girders exposed to elevated temperatures. The applicability of the computer program in tracing the response of PC bridge girders from the initial preloading stage to failure stage, due to combined effects of fire and structure loading, is demonstrated through a case study, and validated by test data of a scaled PC box girder under ISO834 fire condition. Results from the case study show that fire severity has a significant influence on the fire resistance of PC T girders and hydrocarbon fire is most dangerous for the girder. The prestress loss caused by elevated temperature is about 10% under hydrocarbon fire till the girder failure, which can lead to the increase in deflection of the PC girder. The rate of deflection failure criterion is suggested to determine the failure of PC T girder under fire.

A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test (가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구)

  • Sin dong, Kang;Jae-Ho, Kim
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

Bond Capacity of Near-Surface-Mounted CFRP Plate to Concrete Under Various Temperatures (콘크리트에 표면매입 보강된 탄소섬유 판의 온도에 따른 부착성능)

  • Seo, Soo-Yeon;Kim, Jeong-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.75-83
    • /
    • 2013
  • This paper presents a series of test result in order to study fire resistance capacity of the Near-Surface-Mounted (NSM) Carbon Fiber Reinforced Polymer (CFRP) plate, which are tensile test of CFRP under various temperature loading, temperature loading test of epoxy and bond test of NSM CFRP to concrete under various temperature loading. From the tests, it was found that NSM retrofit method had high efficiency in strengthening concrete under ordinary temperature. However, the strength of the system was able to be drastically decreased even a little increase of surrounding temperature. Especially, bond capacity begins to disappear when the surrounding temperature approaches the glass transition temperature of epoxy. Therefore, it is necessary to improve the fire resistance capacity of both fiber reinforced polymer reinforcement and epoxy for bonding in order to develop safe fire resistance design of structure.