• 제목/요약/키워드: Fire resistance properties

검색결과 306건 처리시간 0.026초

Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.105-121
    • /
    • 2014
  • A fundamental limitation of steel structures is the decrease in their load-bearing capacity at high temperatures in fire situations such that structural members may require some additional treatment for fire resistance. In this regard, this paper evaluates the structural stability of fire-resistant steel, introduced in the late 1999s, through tensile coupon tests and proposes some experimental equations for the yield stress, the elastic modulus, and specific heat. The surface temperature, deflection, and maximum stress of fire-resistant steel H-section columns were calculated using their own mechanical and thermal properties. According to a comparison of mechanical properties between fire-resistant steel and Eurocode 3, the former outperformed the latter, and based on a comparison of structural performance between fire-resistant steel and ordinary structural steel of equivalent mechanical properties at room temperature, the former had greater structural stability than the latter through $900^{\circ}C$.

경골목구조 벽체의 내화성능확보를 위한 질석보드 개발 (Development of Vermiculite Board to Secure the Fire Resistance Performance of Light-Frame Wood Structural Wall)

  • 유석형;정창헌
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.40-45
    • /
    • 2018
  • 무기재로서 질석은 친환경적인 특성과 내화, 단열, 흡음 뿐 만 아니라 결로방지, 탈취 및 미관 등이 우수하므로 건축마감재로서 활용될 경우 효용성이 높을 것으로 판단된다. 본 연구에서는 질석을 주원료로 하여 미네랄 루즈울(Mineral Loose Wool) 또는 미네랄 파우더(Mineral Powder)를 혼입한 건축용 마감보드를 개발하고 불연시험과 단열시험을 수행하였다. 시험결과 두 개의 질석보드 모두 불연재로서 성능을 확보하였으며 열전도율 0.086 및 $0.092W/m{\cdot}K$로 나타났다. 또한 개발된 두 개의 질석보드를 경골목구조 내화벽체 표준상세(KS F 1611-1)의 마감재로 적용하여 내화시험을 수행하였다. 내화시험결과 VB-L 시험체가 VB-P시험체 보다 내화성능이 다소 높게 나타났으며 두 개의 질석보드 모두 두께 30 mm로도 내화성능 2시간 확보가 충분한 것으로 나타났다.

폴리믹스 혼입에 의한 고강도 콘크리트의 폭렬방지 방안에 관한 연구 (A study on the fire resistance properties of high strength concrete by incorporation of Polymix fiber)

  • 김정진;이상현;이주호;신재경;박종호;정용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.395-396
    • /
    • 2010
  • 본 연구는 최근 국내 초고층 건물의 고강도콘크리트 화재시 내화성능 확보와 관련하여 자체 연구개발한 폴리믹스(PP섬유 + 폴리머분말)를 적용 80MPa 고강도 콘크리트에 대한 내화성능 확인 실험을 실시함으로써, 초고층 펌프압송이 가능한 초고층용 고내화콘크리트를 개발하는데 그 목적이 있다.

  • PDF

건식화 P0SCO E&C Fire Board (PFB)공법 개발에 관한 연구 (A Study on the Development of a Dry PFB Method with High Fire Resistance)

  • 김우재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.953-956
    • /
    • 2008
  • 국내 초고층 프로젝트의 증가에 따라 필연적으로 고강도 콘크리트의 사용이 증가되고 있다. 콘크리트의 강도가 증가됨에 따라 화재시 단면결손을 유발하는 폭렬의 경향성이 커지고, 콘크리트부재 내부의 온도를 현저하게 증가시키며 심각한 구조적 손상을 유발할 수 있다는 문제점이 대두되었고, 정부에서도 2008년 7월부터 고강도 콘크리트의 내화성능 관리기준을 시행하고 있다. 이에 국내 각 건설사들은50MPa 이상의 고강도 콘크리트에 대하여 폭렬방지 대책을 수립 중에 있다. 본 연구소에서는 신축공사 및 리모델링공사에도 적용이 가능한 고강도 콘크리트 폭렬방지 공법인 PFB (Posco E&C Fire Board) 공법을 개발하여 지속적인 공법 개선에 노력하고 있다. 본 연구는 고강도 콘크리트 폭렬방지 대책으로 개발한 PFB 공법 개발에 대한 일반사항, 현재 건식화 공법 개발 및 당사 PJT적용 현황에 대한 내용을 기술하고자 한다.

  • PDF

내화 마감재 종류에 따른 고성능 RC기둥의 폭열방지 및 온도이력 특성 (Properties of Temperature History and Spatting Resistance of High Performance RC Column with Finishing Material)

  • 허영선;김기훈;이진우;이보형;이재삼;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.37-40
    • /
    • 2005
  • High Performance Concrete(HPC) has been widely used in high-rise building. The HPC has several benefits including high strength, high fluidity and high durability. However. spatting is susceptible to occur in HPC and HPC also tends to be deteriorated in the side of fire resistance performance at fire. This paper focuses on the analysis of the temperature history and residual compressive strength with finishing material, in order to protect HPC from sudden-high-temperature, which is one of the main reason spatting occurs. Test results show that spalling occurs in all specimens. The most serious spalling took placed in HPC covering fire enduring spray-on material, whose covering thickness is 20mm but temperature history indicates that fire enduring spray effectively protected HPC from fire for more than 2hours. In addition, residual compressive strength ratio of HPC using fire enduring paint was more than $90\%$ of original strength, thus minimizing spatting and indicating significant fire resistance performance.

  • PDF

횡구속 방법에 따른 고성능 RC 기둥 콘크리트의 내화특성 (Properties of Fire Endurance of High Performance RC Column with Laterral Confinement Method)

  • 황인성;김기훈;배연기;이보형;이재삼;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.553-556
    • /
    • 2004
  • This paper is to investigate the spalling and fire endurance of high performance RC column member with PP fiber and lateral confinement of metal lath and non fire resistance removal type form. According to test results, combination of PP fiber and metal lath as well as use fire resistance non removal type form had favorable fire resistance by discharging internal vapour pressure and lateral confining. After fire endurance test, compressive strength decreased markedly caused by internal expansion pressure and crack. Residual strength of plain concrete was decreased to $22\%$. The use of PP fiber and lateral confinement of metal lath and non removal type form enhanced the residual strength above $40\%$. Especially, the combination of $0.1\%$ of PP fiber and lateral confinement with the level of 2.3T exhibited more than $51\%$ of residual strength. Therefore, to improve fire endurance and spalling resistance, the combination of $0.1\%$ of PP fiber and metal lath with 2.3T can be the proper measure.

  • PDF

Fire resistance and residual strength of reactive powder concrete Using metakaolin

  • Jang, Hongseok;Yi, Jebang;So, Seungyoung
    • Steel and Composite Structures
    • /
    • 재36권6호
    • /
    • pp.657-669
    • /
    • 2020
  • This study investigates the fire resistance characteristics of reactive powder concrete according to changes in the cement content per unit area, mixing ratio of metakaolin (MK), and content of polypropylene fiber. A fire test was conducted, and the resulting residual strength characteristics were investigated through flexural and compressive strength measurements, as well as condition rating classification based on visual evaluation. MK effectively reduced the initial high content of calcium hydroxide, thereby reducing the water vapor pressure generated during pyrolysis and slowing spalling. Furthermore, the pore structure and loose tissue were effective for relieving the water vapor pressure in the event of a fire.

나노소재를 이용한 콘크리트의 내화성능향상 연구 (A Study on Fire-Resistant Improvement of Concrete with nano size materials)

  • 조병완;박종빈;최해윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.481-484
    • /
    • 2005
  • Recently, Since the advanced nano technology develops unique physical and chemical properties different from those of the conventional materials. Normal concretes mixed with nano size materials have been studied to improve the fire-resistance with high strength and lower heat conductivity. In this pilot study, the nano-particle contents in the specimens ($\Phi$10\times20 cm$) were 0, 2, 4, and 6$\%$ by weight of cement, and fire-temperatures 800$^{circ}C$ was considered. The results show that as the nano-particle contents increases, fire resistance of concrete are superior to those of the ordinary concrete. Also, the experimental results show that fire resistance of nano Aluminum hydroxide dispersed concrete are superior to those of the nano-SiO2 concrete.

  • PDF

복합유기섬유를 사용한 고강도 콘크리트의 기초특성 및 폭렬방지 (Fundamental Properties and Spalling Resistance of High Strength Concrete Containing Hybrid Organic fiber)

  • 배장춘;한동엽;이진우;한창평;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.745-748
    • /
    • 2006
  • This study investigates the fundamental properties and examines spalling appearances and residual compressive strength of high strength concrete containing hybrid organic fibers subjected to fire. Test showed that overall, an increase of fiber content decreased the fluidity of concrete, but specimens containing polyvinyl alcoho(PVA)+polypropylene(PP) fiber and nylon(NY)+PP fiber had improved flow. In addition, the air content of all specimens was properly ranged in target value, regardless of fiber content. As for the spalling properties when completed the fire test, control concrete exhibited spalling occurrence due to sudden elevated temperature. However, specimens containing more than 0.1 vol% of PP fiber prevented the spalling, while specimens containing PP+CL and PVA+PP fiber can protected from fire in more than 0.15vol% of the fiber content. Importantly, a specimen containing only 0.05vol% of NY+PP showed the favorable spalling resistance performance.

  • PDF

길이변화에 따른 기둥부재의 내화피복 비교연구 (Comparative Study for Fire Protective Materials of Column According to Variance of Lengths)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.118-119
    • /
    • 2014
  • A fire in a steel framed building can decrease a structural stability and cause deformation. And the fire continues the building can be demolished. Therefore, every country requires fire resistance performance of structural elements. In case of column, fire protective thickness derived from a specific fire test using an horizontal furnace is allowed to apply any kinds of sections and lengths of column. However, the lengths and sections of the column in steel framed buildings are various. In this paper, to know the differences of fire performance of steel column according to variance of lengths, a maximum allowable stress, steel surface temperature history, deflection are calculated and the thickness of fire protective material for longer column(4700 mm) need to enforce about 10% more than shorter column (3500 mm).

  • PDF