• Title/Summary/Keyword: Fire prevention property

Search Result 97, Processing Time 0.023 seconds

A Study on Training System for Fire Prevention based on Virtual Reality (가상현실 기반 화재대응 훈련 시스템에 관한 연구)

  • Song, Eun-Jee
    • Journal of Digital Contents Society
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2016
  • According to the National Statistical Office, the number of fires was the 42,135 items in 2014, it has increased reviews 1203 compare with 2013. In addition, the sum of the property damage 2,560 billion, injured number 1,599 people, it was announced in deaths number 263 people. Although Korea government have announced many fire manuals for fire prevention, the reason that many of the wounded and the dead occurred is because people have recognized fire riskiness in just only head simply from manual. In this paper, the simulation system for prevention of fire based virtual reality is proposed to solve this problems. The people who trained by proposed system can recognize and realize fire riskiness more than fire writing manuals.

Development for the Water Mist Package Having a Low Pressure Nozzles on Wooden Cultural Properties and Temples (중저압 노즐을 이용한 사찰 및 목조 문화재용 미분무 패키지 소화설비 개발)

  • Kim, Tae-Hwan;Myeong, Sang-Yeong
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.62-68
    • /
    • 2010
  • The present study purposed to develop the water mist package system for the cultural properties fire prevention and fire suppression system through analyzing fire protection system and cultural property's characteristic, and to suggest directions for the development of cultural property fire prevention system in the future. Maximum safety with minimum damage has issued a main objective in fire protection of the cultural property in Korea. Two types of the water mist nozzles having a low pressure had been developed by KEI. The one is for inside using in wooden cultural properties, the flow rate is 30~35 l/min and the discharging pressure is 13~14 bar. The other one is for out-side of wooden properties, the flow rate is 25~30 l/min and the discharging pressure is 14~15 bar. To evaluate the nozzles performance test, we made the fire scenario and full-scale model of wooden cultural properties for fire test. The size of full-scale model was 4.9 m length, 4 m wide, 6.6 m height, all was made by wooden. This real fire test results showed that the low pressure water mist nozzles having a $200{\mu}m$ dour size were very effectively fire extinguishing and suppression on wooden cultural properties fire. Even though the oil fuel fire was not extinguished, the fire suppression effects for the during mobilization of fire brigade was enough.

A Study on the Revitalization Method of the Korean Volunteer Fire Brigade (한국의용소방대의 활성화 방안에 관한 연구)

  • Lee, Jeom-Dong;Yoon, Myong-O;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.95-104
    • /
    • 2008
  • It is essential that the operational system of volunteer fire brigade (VFB) playing a important role in the local disaster prevention should be effectively improved to live in safety by protecting life and property of inhabitants from a disaster. The results of this research showed that most of volunteering members of fire brigade was highly satisfied with their works and thus they voluntarily did volunteer activities. It was also found that the development of the professional education program and training course about disaster prevention should be required because members of the volunteer fire brigade lacked expertise about the disaster prevention. Moreover, in order to activate and expand VFB, the establishment of the fundamental ideology about the activities of VFB, the introduction of effective selection examination system for the VFB and the creation of department fully responsible for the management of the VFBs should be necessary as well.

Improvement of cultural heritage disaster management - The Case of Sungnyemun's Collapse in Fire - (문화재 재난관리의 필요성과 발전방향 - 숭례문 화재사고사례를 중심으로 -)

  • Han, Beum-Deuk
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.10
    • /
    • pp.189-197
    • /
    • 2008
  • The present study purposed to assert the necessity of cultural property disaster control through analyzing the fire of the Sungnyemun and to suggest directions for the development of cultural property disaster control in the future. For these purposes, we reviewed literature such as research papers and books on cultural property disaster control, and presented problems in current cultural property disaster control and solutions for the problems through case study of the fire of the Sungnyemun. In a word, the fire of the Sungnyemun is a representative case showing difficulty in disaster prevention activities for wooden cultural properties. Accordingly, we need to recognize the necessity of cultural property disaster control and to prepare measures. For this, first, it is essential to reinforce preventive systems against cultural property disasters. Second, early actions should be taken in consideration of the characteristics of each cultural property. Third, for cultural property disaster control, it is important to maintain cooperative relations among the Cultural Properties Administration, National Emergency Management Agency, and relevant local self.governing bodies. Lastly, standards for cultural property fire protection systems should be tightened by improving related laws, and institutional bases should be intensified through preparing grounds for aggravated punishment for crimes against cultural properties such as arsons.

Fire due to an important national cultural protection measures research (화재로 인한 국가 중요 문화재 보호대책 연구)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.485-500
    • /
    • 2013
  • Cultural assets of the country's history and cherish the living conditions of the people, conscious and cohesive crystals, and the pride of the hearts of the people as a haven. In the country worth preserving national treasure, bomulgeup, local cultural heritage as a major cultural property protection are. Cultural properties, etc. Most are wooden, is vulnerable to fire, and, moreover battling to far away from the city and due to the geographical conditions are very challenging aspects. The national cultural assets, such as the many temples, vows to fire one if the loss of a centuries-old cultural property is a big loss of national posterity to great shame is not. Still cultural assets and a large number of visitors have flocked temples. All of us to keep the look and feel of the cultural assets pleasure to conserve cultural assets preserved to ensure that fire prevention is always unmistakably bear in mind that sees.

  • PDF

Deregulation of the Fire Prevention Legislation; and Its Impact on Fire Occurrence - Case of the United Kingdom - (′화재예방법규′의 규제완화가 화재발생에 미치는 영향 -영국 사례분석 -)

  • 이재열
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • The OECD defines regulatory reform as both better regulation and deregulation, and emphasizes that governments must continue to regulate in areas such as environmental quality and safety. In contrast, Korean regulatory reform in fire services in the 1990s shows quite a strange trend, having been carried out only to the direction of softening and abolishing regulations. In the UK, fire prevention legislation has been strengthened since the enactment of the Fire Precautions Act 1971, and the Building Regulations 1991, which apply to all new buildings including a private house, require that there should be at least one smoke alarm on each floor. This research shows that the tightening of fire prevention legislation in the UK has promoted fire safety, which is very instructive for Korean fire services. In order for Korean fire services to protect citizens'lives and property from fires, one of basic directions of regulatory reform, to improve the quality of regulations relating to safety, health and the environment, should be observed strictly. Moreover, the flexibility of the basic direction of regulatory reform should be ensured so that the regulations concerning safety could be even increased under the overall reform strategy of reducing all regulations.

  • PDF

A Study on the Improvement of Anti-Fire System of Temples (사찰 화재예방시스템의 개선방안에 관한 연구)

  • Kong, Ha-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.87-90
    • /
    • 2008
  • This research is to study and analyze our country's management of disasters, the present condition of cultural heritages bases on the examples of temples, and Japan's safety management prevention of buddhist temple. As a result, this research aims to how to improve the temple fire prevention system. To improve the anti-fire system of temples, it is important to make new laws about fire lose to minimize cultural property lose. Secondly, to protect self-contained type fire alarm device, with aerosol type hand propelled fire extinguishers to prevent fire lose. Lastly, construction work of electric engineer is necessary to prevent temple fire loses.

The Analysis of the Risk of Vehicle Fires in Korea and the Effectiveness of Initial Fire Extinguishing (국내 자동차 관련 화재발생 위험성 분석 및 초기소화의 효과성 연구)

  • Ryu, Juyeol;Lee, Changwoo
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.20-27
    • /
    • 2019
  • Purpose: In this study, the status and the risk of fire occurrence in domestic automobile were evaluated and the damage reduction effect by using the fire extinguishing mechanism was evaluated. Method: The analysis of the risk of the occurrence of Vehicle Fires in Korea and the damage of human and property by the use of fire extinguisher applied to fire extinguisher were investigated and analyzed. Results: The annual damage rate of the damage caused by the automobile fire is 4.74%, which shows an annual increase. As a result of the analysis of the personal injury caused by the passenger car in the car fire situation, the damage amount per 100 cases of the fire occurrence increased from 424.65 million won to 473.06 million won in the past 5 years (2012 ~ 2016). Conclusion: When fire extinguishers are used in the case of passenger Vehicle Fires, the average amount of property damage per fire occurrence is estimated to be about 307.5 million, emphasizing the importance and necessity of the initial fire fighting.

A Study on the mitigation method of explosion and fire accidents in the Boiler room (보일러실 화재.폭발사고 경감방안에 관한 연구)

  • Son, Eun-Soo;Baek, Myoung-Gi;Song, Jae-Su;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.405-409
    • /
    • 2007
  • This paper focused on the way of prevention of disaster in the accident of explosion when the fire broke out in the boiler room where installed the basement of the building, and showed the effective ways for sustaining people and property safely in the view of problems and improvement of the law and safety awareness of people.

  • PDF

A Study on Safety by Risk Assessment of Clean Room (Clean Room 위험성 평가에 따른 안전성 확보에 관한 연구)

  • Song Yun-Suk;Yoon Myong-O;Hyun Seong-Ho;Lee Chang-Woo;Yoon Yo-Song;Kim Sung-Min
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.78-85
    • /
    • 2004
  • This research analyzes Clean Room accidents, and presents research Clean Room, major fire prevention standards of Clean Room (FM, IRI, and NFPA Code), various results from Fire Simulation of analysis. The results are : the smoke diffusion is very quick coupled with the Heating, Ventilating, and Air Conditioning (HVAC) systems under fire ; the possibility of getting the result and the possibility the role of the Sprinkler systems to reduce the diffusion of the smoke. We learn about the importance to stop operating Heating, Ventilating, and Air Conditioning (HVAC) systems and to operate the Sprinkler system for securing safety with fire detection. Therefore, This research will be contributing to secure safety of Clean Room.