• Title/Summary/Keyword: Fire monitoring

Search Result 401, Processing Time 0.026 seconds

Appropriate Smart Factory : Demonstration of Applicability to Industrial Safety (적정 스마트공장: 산업안전 기술로의 적용 가능성 실증)

  • Kwon, Kui-Kam;Jeong, Woo-Kyun;Kim, Hyungjung;Quan, Ying-Jun;Kim, Younggyun;Lee, Hyunsu;Park, Suyoung;Park, Sae-Jin;Hong, SungJin;Yun, Won-Jae;Jung, Guyeop;Lee, Gyu Wha;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.196-205
    • /
    • 2021
  • As industrial safety increases, various industrial accident prevention technologies using smart factory technology are being studied. However, small and medium enterprises (SMEs), which account for the majority of industrial accidents, are having difficulties in preventing industrial accidents by applying these smart factory technologies due to practical problems. In this study, customized monitoring and warning systems for each type of industrial accident were developed and applied to the actual field. Through this, we demonstrated industrial accident prevention technology through appropriate smart factory technology used by SMEs. A customized monitoring system using vision, current, temperature, and gas sensors was established for the four major disaster types: worker body access, short circuit and overcurrent, fire and burns due to high temperature, and emission of hazardous gas. In addition, a notification method suitable for each work environment was applied so that the monitored risk factors could be recognized quickly, and real-time data transmission and display enabled workers and managers to understand the disaster risk effectively. Through the application and demonstration of these appropriate smart factory technologies, the spread of these industrial safety technologies is to be discussed.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

A Monitoring System for Working Environments Using Wireless Sensor Networks (무선 센서 네트워크를 이용한 작업환경 모니터링 시스템)

  • Jung, Sang-Joon;Chung, Youn-Ky
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.10
    • /
    • pp.1478-1485
    • /
    • 2009
  • A sensor network which is composed of a large number of sensors that perform various sensing is applied in a variety of fields. The sensor networks can be widely used for various application area like as home automation, fire detection and security area. Development of new sensor to have appropriate functions and deployment of networks for suitable application are served actively. In this paper, we design and implement a system that monitors various factory facilities by deploying sensor network at a working place which threatens the worker's safety. A sensor node reports its sensing data like as temperature and humidity to monitor facilities to a sink node. And the server which is connect to the sink node gathers and provides information by user interface. In addition, digital data which are generated at a work place can be transferred via the sensor network to increase the efficiency of works. The proposed sensor network provides the convenience of working, since it is deployed at a garbage collection company to monitor a temperature and humidity of garbage and to transmit data about the weight of trucks which enters the company.

  • PDF

Monitoring Mount Sinabung in Indonesia Using Multi-Temporal InSAR

  • Lee, Chang-Wook;Lu, Zhong;Kim, Jin Woo
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.1
    • /
    • pp.37-46
    • /
    • 2017
  • Sinabung volcano in Indonesia was formed due to the subduction between the Eurasian and Indo-Australian plates along the Pacific Ring of Fire. After being dormant for about 400 years, Sinabung volcano erupted on the 29th of August, 2010 and most recently on the 1st of November, 2016. We measured the deformation of Sinabung volcano using Advanced Land Observing Satellite/Phased Array type L-band Synthetic Aperture Radar(ALOS/PALSAR) interferometric synthetic aperture radar(InSAR) images acquired from February 2007 to January 2011. Based on multi-temporal InSAR processing, we mapped the ground surface deformation before, during, and after the 2010 eruption with time-series InSAR technique. During the 3 years before the 2010 eruption, the volcano inflated at an average rate of ~1.7 cm/yr with a markedly higher rate of 6.6 cm/yr during the 6 months prior to the 2010 eruption. The inflation was constrained to the top of the volcano. From the 2010 eruption to January 2011,the volcano subsided by approximately 3 cm (~6 cm/yr). We interpreted that the inflation was due to magma accumulation in a shallow reservoir beneath Sinabung. The deflation was attributed to magma withdrawal from the shallow reservoir during the eruption as well as thermo-elastic compaction of erupted material. This result demonstrates once again the utility of InSAR for volcano monitoring.

Association Between Leisure Time Physical Activity, Cardiopulmonary Fitness, Cardiovascular Risk Factors, and Cardiovascular Workload at Work in Firefighters

  • Yu, Clare C.W.;Au, Chun T.;Lee, Frank Y.F.;So, Raymond C.H.;Wong, John P.S.;Mak, Gary Y.K.;Chien, Eric P.;McManus, Alison M.
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.192-199
    • /
    • 2015
  • Background: Overweight, obesity, and cardiovascular disease risk factors are prevalent among firefighters in some developed countries. It is unclear whether physical activity and cardiopulmonary fitness reduce cardiovascular disease risk and the cardiovascular workload at work in firefighters. The present study investigated the relationship between leisure-time physical activity, cardiopulmonary fitness, cardiovascular disease risk factors, and cardiovascular workload at work in firefighters in Hong Kong. Methods: Male firefighters (n = 387) were randomly selected from serving firefighters in Hong Kong (n = 5,370) for the assessment of cardiovascular disease risk factors (obesity, hypertension, diabetes mellitus, dyslipidemia, smoking, known cardiovascular diseases). One-third (Target Group) were randomly selected for the assessment of off-duty leisure-time physical activity using the short version of the International Physical Activity Questionnaire. Maximal oxygen uptake was assessed, as well as cardiovascular workload using heart rate monitoring for each firefighter for four "normal" 24-hour working shifts and during real-situation simulated scenarios. Results: Overall, 33.9% of the firefighters had at least two cardiovascular disease risk factors. In the Target Group, firefighters who had higher leisure-time physical activity had a lower resting heart rate and a lower average working heart rate, and spent a smaller proportion of time working at a moderate-intensity cardiovascular workload. Firefighters who had moderate aerobic fitness and high leisure-time physical activity had a lower peak working heart rate during the mountain rescue scenario compared with firefighters who had low leisure-time physical activities. Conclusion: Leisure-time physical activity conferred significant benefits during job tasks of moderate cardiovascular workload in firefighters in Hong Kong.

Development of Wireless Base Station Remote Monitoring System Using IoT Based on Cloud Server (클라우드 서버 기반 IoT를 이용한 무선기지국 원격 감시시스템 개발)

  • Lee, Yang-weon;Kim, Chul-won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.849-854
    • /
    • 2018
  • Radio base stations, which are widely distributed across large areas, have many difficulties in managing them. Unmanned radio base stations in remote mountains are having a hard time accessing them in case of emergencies. Major telephone service providers only remotely control incoming and outgoing information and local small business partners responsible for maintaining actual facilities do not possess such technologies, so they are each checked during field visits. In this study, in order to process the sensor raw data and smoothing, we apply the particle filters and confirmed that the performance of sensor data accuracy is increased. Integrated system using temperature, humidity, fire condition, and power operation at a wide range of radio base stations under the real-time monitoring status is operated well. It show that all of the status of base station are monitored at the remote office using the cloud server through internet networking.

RETRIEVAL OF AEROSOL MICROPHYSICAL PARAMETER BY INVERSION ALGORITHM USING MULTI-WAVELENGTH RAMAN LIDAR DATA

  • Noh, Young-Min
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.298-301
    • /
    • 2007
  • Vertical distribution and optical properties of atmospheric aerosols above the Korean peninsula are quite important to estimate effects of aerosol on atmospheric environment and regional radiative forcing. For the first time in Korea, vertical microphysical properties of atmospheric aerosol obtained by inversion algorithm were analyzed based on optical data of multi-wavelength Raman lidar system developed by the Advanced Environmental Monitoring Research Center (ADEMRC), Gwangju Institute Science and Technology (GIST). Data collected on 14 June 2004 at Gwangju ($35.10^{\circ}N$, $126.53^{\circ}E$) and 27 May 2005 at Anmyeon island ($36.32^{\circ}N$, $126.19^{\circ}E$) were used as raw optical data for inversion algorithm. Siberian forest fire smoke and local originated haze were observed above and within the height of PBL, respectively on 14 June 2004 according to NOAA/Hysplit backstrajectory analysis. The inversion of lidar optical data resulted in particle effective radii around 0.32 ${\mu}m$, single scattering albedo between 0.97 at 532 nm in PBL and effective radii of 0.27 ${\mu}m$ and single scattering albedo of 0.92 above PBL. In the case on 27 May 2005, biomass burning from east China was a main source of aerosol plume. The inversion results of the data on 27 May 2005 were found to be particle effective radii between 0.24 ${\mu}m$, single scattering albedo around 0.91 at 532 nm. Additionally, the inversion values were well matched with those of Sun/sky radiometer in measurement period.

  • PDF

Development of a Customized Beacon Equipped with a Strain Gauge Sensor to Detect Deformation of Structure Displacement (구조물의 변위 변형 감지를 위한 변형률 센서를 장착한 커스터마이징 비콘 개발)

  • Kim, Junkyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.1-7
    • /
    • 2021
  • This study attempted to detect possible collapse and fire accidents in facilities for disaster monitoring of large facilities, and to develop a customized beacon to recognize the internal situation of an IoT-based facility when a disaster occurs. In the case of data measurement using the existing strain gauge sensor, the strain gauge sensor was connected by wire to measure it, but this study changed it to wireless so that the presence and absence of structural deformation can be monitored in real time. In this process, in order to use the Wheatstone bridge, a strain sensor module that can be connected to a customized beacon was manufactured, and a system configuration was conducted to remotely check the measurement data. To verify measurement data, 10 customized beacons and 2 gateways were installed on the 15th floor of the Advanced Institue of Convergence Technology, and as a result of analysis of measurement data, it was confirmed that the strain data values were distributed between 7 and 8.

Analysis of Rainfall-Runoff Characteristic at Mountainous Watershed Using GeoWEPP and SWAT Model (GeoWEPP과 SWAT 모델을 이용한 산지 유역 강우-유출량 특성 분석)

  • Kim, Jisu;Kim, Minseok;Kim, Jin Kwan;Oh, Hyun-Joo;Woo, Choongshik
    • Journal of The Geomorphological Association of Korea
    • /
    • v.28 no.2
    • /
    • pp.31-44
    • /
    • 2021
  • Due to recent climate change, continuous soil loss is occurring in the mountainous watershed. The development of geographic information systems allows the spatial simulation of soil loss through hydrological models, but more researches applied to the mountain watershed areas in Korea are needed. In this study, prior to simulating the soil loss characteristics of the mountainous watershed, the field monitoring and the SWAT and GeoWEPP models were used to simulate and analyze the rainfall and runoff characteristics in the mountainous watershed area of Jirisan National Park. As a result of monitoring, runoff showed a characteristic of a rapid response as rainfall increased and decreased. In the simulation runoff results of calibrated SWAT models, R2, RMSE and NSE was 0.95, 0.03, and 0.95, respectively. The runoff simulation results of the GeoWEPP model were evaluated as 0.89, 0.30, and 0.83 for R2, RMSE, and NSE, respectively. These results, therefore, imply that the runoff simulated through SWAT and GeoWEPP models can be used to simulate soil loss. However, the results of the two models differ from the parameters and base flow of actual main channel, and further consideration is required to increase the model's accuracy.

Comparison of the relative importance of educational content, teaching methods, and evaluation methods in the patient assessment curriculum for 119 EMTs (119구급대원 대상 환자평가 교육과정에서 교육내용, 교수법, 평가 방법의 상대적 중요도 비교)

  • Ah-Ram Seo;Jun-Dong Moon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.1
    • /
    • pp.97-112
    • /
    • 2024
  • Purpose: This study compared the relative importance of educational content, teaching methods, and evaluation methods in the patient assessment curricula of 119 emergency medical technicians (EMTs). Methods: First, we identified the educational content, training hours, and teaching and evaluation methods of the existing patient assessment curriculum based on the National Competency Standard learning module. Second, we surveyed 30 EMTs affiliated with 119 services using the Analytic Hierarchy Process (AHP) method. Subsequently, we compared the differences between the current curriculum and the AHP analysis results. Results: Currently in operation, the "Advanced EMT Course" comprises three learning modules: assessment of patient status, scene size-up and triage, and assessment using monitoring devices. Among these, content related to the assessment of patient status received the most allocated time and was deemed the most important according to the AHP survey results. Conversely, while less time was allocated to scene size and triage compared with assessment using monitoring devices, the former was assessed as more important than the latter in the AHP results. Furthermore, scenario-based team training and procedure-focused individual practice were evaluated as relatively important teaching methods, while practical examination using a checklist was deemed the most appropriate evaluation method for all learning content. Conclusion: To improve the patient assessment curriculum, we propose adjusting teaching hours and introducing new teaching and evaluation methods based on the results of relative importance. The proposed improvement plan will contribute to enhancing the competency of 119 EMTs.