• 제목/요약/키워드: Fire monitoring

검색결과 401건 처리시간 0.029초

2003년 5월 러시아지역에서 발생한 산불로 인한 스모크 에어로졸 플룸의 영향 (Impact of the Smoke Aerosol from Russian Forest Fires on the Atmospheric Environment over Korea during May 2003)

  • 이권호;김정은;김영준;김준
    • 한국대기환경학회지
    • /
    • 제20권5호
    • /
    • pp.603-613
    • /
    • 2004
  • Extensive forest fires occurred across the border in Russia. particularly east of Lake Baikal between the Amur and Lena rivers in May 2003. These forest fires released large amounts of particulates and gases into the atmosphere. resulting in adverse effects on regional air quality and the global radiation budget. Smoke pollution from the Russian fires near Lake Baikal was sometimes transported to Korea through Mongolia and eastern China. In this study ground based radiation (visible and UV-B) data measured during May 2003 at Seoul and Kwangju were analyzed to estimate smoke aerosol impacts on solar radiation. Surface criteria air pollutants ($PM_{10}$, CO, $O_3$) data were also obtained from National Institute of Environmental Research (NIER) during smoke aerosol event period (19 May~24 May 2003). Large Aerosol Optical Depth (AOD) 1.0~3.0 was observed during this period due to the influence of the long range transport of smoke aerosol plume from the Russian fires, resulting in short-wavelength direct aerosol radiative forcing of -90~ -200W/$m^2$. These smoke aerosol plume caused decrease in surface UV-B radiation up to 80% and increase in PM_(10) concentration up to 200${\mu}g/m^3$ exceeding the 24 hour ambient air quality standard.

역행렬 알고리즘을 이용한 다파장 라만 라이다 데이터의 고도별 에어로졸 Microphysical Parameter 도출 (Retrieval of Aerosol Microphysical Parameter by Inversion Algorithm using Multi-wavelength Raman Lidar Data)

  • 노영민;김영준
    • 한국대기환경학회지
    • /
    • 제23권1호
    • /
    • pp.97-109
    • /
    • 2007
  • Vertical distribution and optical properties of atmospheric aerosols above the Korean peninsula are quite important to estimate effects of aerosol on atmospheric environment and regional radiative forcing. For the first time in Korea, vertical microphysical properties of atmospheric aerosol obtained by inversion algorithm were analyzed based on optical data of multi-wavelength Raman lidar system developed by the Advanced Environmental Monitoring Research Center (ADEMRC), Gwangju Institute Science and Technology (GIST). Data collected on 14 June 2004 at Gwangju ($35.10^{\circ}N,\;126.53^{\circ}E$) and 27 May 2005 at Anmyeon island ($36.32^{\circ}N,\;126.19^{\circ}E$) were used as raw optical data for inversion algorithm. Siberian forest fire smoke and local originated haze were observed above and within the height of PBL, respectively on 14 June 2004 according to NOAA/Hysplit backstrajectory analysis. The inversion of lidar optical data resulted in particle effective radii around $0.31{\sim}0.33{\mu}m$, single scattering albedo between $0.964{\sim}0.977$ at 532 nm in PBL and effective radii of $0.27{\mu}m$ and single scattering albedo between $0.923{\sim}0.924$ above PBL. In the case on 27 May 2005, biomass burning from east China was a main source of aerosol plume. The inversion results of the data on 27 May 2005 were found to be particle effective radii between $0.23{\sim}0.24{\mu}m$, single scattering albedo around $0.924{\sim}0.929$ at 532 nm. Additionally, the inversion values were well matched with those of Sun/sky radiometer in measurement period.

수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발 (Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network)

  • 양승연;김진태;오환진;이민우
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.83-86
    • /
    • 2015
  • 본 논문에서는 수처리 시설용 광대역 통합망 연계 실시간 계측관리 시스템 UI 개발을 제안한다. 수처리시설용 광대역 통합망을 통해 서버로 수신된 센서 및 영상 데이터를 Web과 연동하기 위한 프로그램을 개발하며, 이와 별도로 독립적으로 운영이 가능한 UI를 개발한다. 전송된 센서 및 영상데이터를 원격 모니터링 하기 위한 웹 서버를 구축하며 센서 데이터, 영상 데이터를 Web기반의 UI를 통해 감시 및 제어가 가능하도록 개발하였다. 제안하는 수처리 시설용 광대역 통합망 연계형 실시간 계측관리 시스템을 통하여 센서를 통한 측정시간, 농도, 수심 계면 등의 현재 상태를 파악할 수 있으며 영상 모니터링을 통하여 실시간으로 수처리 시설의 정상적인 동작여부와 보안 및 화재 등의 인명피해 여부를 확인 할 수 있다. 뿐만 아니라 실시간 계측 관리 시스템을 실시간으로 모니터링 할 수 있는 UI 개발로 인해 실시간으로 정보를 한눈에 볼 수 있다.

상황인식 기반 개인 선박 상태감시시스템 설계 및 구현 (A Design and Implementation of Personal Vessel Monitoring System Based on Context Aware)

  • 신도성;이성로
    • 대한전자공학회논문지SP
    • /
    • 제48권3호
    • /
    • pp.112-118
    • /
    • 2011
  • 선박은 위급상황에 노출될 경우 육상의 교통수단에 비해 해양 환경이라는 제약성 때문에 그 위험성이 더 크다. 따라서 위험 요소를 사전에 발견하고 먼저 조치를 취하는 것이 매우 중요하다. 이 논문에서는 선박에 가해지는 위험 요소를 지속적으로 감시하고 상태를 파악할 수 있는 상태감시시스템을 제안하였으며 이를 위해 선박 내에 화재 센서 모듈, 기울기 센서와 비틀림 센서를 설치하여 선박의 안전 상황을 판가름하는 기초가 되는 센서 데이터를 수집하였다. 획득한 센서 데이터는 역전파 신경망을 설계하여 분석하였으며 분석된 데이터를 토대로 판단한 선박 상태 정보는 승무원의 개인 단말기로 송신되어 이동 상황에서도 선박의 상태를 실시간으로 점검할 수 있다. 상황인식 실험 결과 연출된 화재 상황에서 약 95%의 정확도를 보였고 선체의 충격 위험 요소에 대해서 약 89%의 정확도를 보였다.

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;김유성;송윤호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

Internet of Things-Based Command Center to Improve Emergency Response in Underground Mines

  • Jha, Ankit;Verburg, Alex;Tukkaraja, Purushotham
    • Safety and Health at Work
    • /
    • 제13권1호
    • /
    • pp.40-50
    • /
    • 2022
  • Background: Underground mines have several hazards that could lead to serious consequences if they come into effect. Acquiring, evaluating, and using the real-time data from the atmospheric monitoring system and miner's positional information is crucial in deciding the best course of action. Methods: A graphical user interface-based software is developed that uses an AutoCAD-based mine map, real-time atmospheric monitoring system, and miners' positional information to guide on the shortest route to mine exit and other locations within the mine, including the refuge chamber. Several algorithms are implemented to enhance the visualization of the program and guide the miners through the shortest routes. The information relayed by the sensors and communicated by other personnel are collected, evaluated, and used by the program in proposing the best course of action. Results: The program was evaluated using two case studies involving rescue relating to elevated carbon monoxide levels and increased temperature simulating fire scenarios. The program proposed the shortest path from the miner's current location to the exit of the mine, nearest refuge chamber, and the phone location. The real-time sensor information relayed by all the sensors was collected in a comma-separated value file. Conclusion: This program presents an important tool that aggregates information relayed by sensors to propose the best rescue strategy. The visualization capability of the program allows the operator to observe all the information on a screen and monitor the rescue in real time. This program permits the incorporation of additional sensors and algorithms to further customize the tool.

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;송윤호;김유성
    • 한국지반공학회논문집
    • /
    • 제23권4호
    • /
    • pp.15-24
    • /
    • 2007
  • 본 연구에서는 여러 지점의 온도를 동시에 측정할 수 있는 두 가지 온도 모니터링 기법을 소개하고 있다. 그 하나는 고유주소를 가지고 있는 온도센서로 구성된 온도센서 배열 케이블을 이용하는 기법이며, 다른 하나는 광섬유 센서를 이용하여 분포 온도를 측정하는 기법이다. 이 두 기법의 차이점은 다음과 같이 요약될 수 있다. 온도센서 배열 케이블은 온도센서가 위치하는 정확한 지점의 온도를 측정하게 된다. 그에 대한 온도 측정의 정밀도 및 분해능은 그 온도 센서의 성능에 따라 결정된다. 한편, 광섬유 센서는 레이저 펄스가 광섬유를 따라 보내질 때 생성되는 Raman 역산란파를 분석함으로써 온도를 측정하기 때문에 분포 개념의 온도를 측정하게 된다. 그에 대한 온도 분해능은 측정거리, 측정시간 및 온도측정 거리분해능에 따라 결정된다. 본 논문은 두 가지 온도 모니터링 시스템의 장단점을 비교함으로써 기술적이고 경제적인 측면에서 그의 응용분야를 면밀히 검토하는 데 그 목적이 있다. 이를 위해 두 기법을 이용한 다양한 실험을 실시하였다. 그 결과를 검토해 보면 온도센서 배열 케이블은 300m 범위 내의 지하수 흐름, 지열 분포 및 그라우팅 효과 검증에 적합할 것으로 판단되며 광섬유 센서는 상대적으로 긴 거리에 걸친 분포 온도에 대한 정보가 필요한 파이프 파인 감시, 터널 화재 감시 및 전력선 모니터링과 같은 분야에서 효율적으로 활용될 것이 기대된다.

Comparison of Classification Rate for PD Sources using Different Classification Schemes

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.257-262
    • /
    • 2006
  • Insulation failure in an electrical utility depends on the continuous stress imposed upon it. Monitoring of the insulation condition is a significant issue for safe operation of the electrical power system. In this paper, comparison of recognition rate variable classification scheme of PD (partial discharge) sources that occur within an electrical utility are studied. To acquire PD data, five defective models are made, that is, air discharge, void discharge and three types of treeinging discharge. Furthermore, these statistical distributions are applied to classify PD sources as the input data for the classification tools. ANFIS shows the highest rate, the value of which is 99% and PCA-LDA and ANFIS are superior to BP in regards to other matters.

도시철도 환경에서 지능형 감시 시스템 구축 사례 (A Case Study on Intelligent Surveillance System for Urban Transit Environment)

  • 장일식;안태기;조병목;박구만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1722-1728
    • /
    • 2011
  • The security issue in urban transit system has been widely considered as the common matters after the fire accident at Daegu subway station. The safe urban transit system is highly demanded because of the vast number of daily passengers, and it is one of the most challenging projects. We introduced a test model for integrated security system for urban transit system and built it at a subway station to demonstrate its performance. This system consists of cameras, sensor network and central monitoring software. We described the smart camera functionality in more detail. The proposed smart camera includes the moving objects recognition module, video analytics, video encoder and server module that transmits video and audio information.

  • PDF

스마트 아웃렛 시스템을 위한 무선 센서네트워크 프로토콜 설계 및 구현 (Design and Implementation of a Wireless Sensor Network Protocol for a Smart Power Outlet System)

  • 정한수;문정호;박성욱;이형봉;박래정;정태윤
    • 대한임베디드공학회논문지
    • /
    • 제7권6호
    • /
    • pp.291-300
    • /
    • 2012
  • This paper deals with the design and implementation of wireless sensor network protocol for smart power outlet system capable of fire detection, power monitoring, standby power cutoff, and home automation. The proposed protocol integrates both the CSMA and the TDMA protocols for low power consumption and good scalability. A prototype smart power outlet system employing the proposed protocol and a simple home automation network including the power outlet system have been implemented for evaluating the feasibility of the proposed protocol The result shows that the proposed protocol allows the power outlet system to be scalable with high power efficiency.