• Title/Summary/Keyword: Fire monitoring

Search Result 401, Processing Time 0.038 seconds

Realization of Information Visualization of Electric Power Monitoring System for MV/LV Distribution Customers

  • Kim Jae-Chul;Chu Cheol-Min;Knag Bong-Seok;Kim Yeong-Il;Choi Duck-Su;Kim Kwang-Soon;Ryu Seung-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.287-294
    • /
    • 2006
  • Recently, switchboards for MV/LV distribution customers have been united and digitalized rapidly. This paper proposes the effective information visualization method for the data measured from cubicle switchboards for MV/LV distribution customers. We developed the algorithm that analyzes abundant data measured by switchboards and displays them to overall users, such as fire information index, power condition index, switchboard safety index, and power diminution index. Using a touch screen made users to operate it easily. User interface was also improved by taking graphic visualization. We guess the information visualization method suggested in this paper shows the new direction that heavy electrical equipments including switchboards are going to develop in the future.

Study on The QoS Monitoring Mechanism of Ad-hoc Network (Ad-hoc 네트워크에서 QoS 모니터링 기법에 대한 연구)

  • 이광제;안종득;윤영한
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.361-367
    • /
    • 2003
  • Ad-hoc network is a multi-hop wireless network formed by a collection of mobile nodes without the aid of any establish infrastructure and this network can provide an extremely flexible method for establishing communications for fire, safety, rescue operations, battle field or other fields requiring rapidly deployable communications with survivable, efficient dynamic networking. Recently new expended mechanism is proposed as Ad-hoc relay system, so guarantee of QoS for multimedia applications is needed more and more. In this paper, we propose ARM based QoS Distribution Monitoring Mechanism to provide Quality of Service guarantees to multimedia application with MANET.

  • PDF

Line of Sight Vector Estimation using UWB for Augmented Reality Based Indoor Location Monitoring System

  • Chun, Sebum;Seo, Jae-Hee;Lee, Sangwoo;Heo, Moon-Beom
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.3
    • /
    • pp.145-156
    • /
    • 2016
  • A variety of methods for indoor positioning systems have been underway to ensure the safety of emergency rescuers who are working in dangerous situations such as fire fighters. However, since most systems display locations of rescue workers in two-dimension (2D)-based maps, it is difficult for a commander located in the outside to recognize locations of rescuers inside the building intuitively. An augmented reality (AR)-based indoor positioning monitoring system can display locations of rescuer inside the building that can be seen by commanders to help intuitive recognition of positioning. To monitor AR-based indoor positioning, it is necessary to have an estimation technique of line of sight vector of observers. In the present study, an estimation technique of a line of sight vector using ultra-wide band tranceiver installed inside the indoor to trace locations is presented.

Development of Expert System for the Fault Diagnosis of Chemical Facility System (화학설비 시스템의 이상고장진단을 위한 Expert System의 개발)

  • Oh, Jae-Eung;Shin Jun;Shin, Ki-Hong;Kim, Doo-Hwan;Kim, Woo-Taek;Lee, Chung-Hwi
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.639-642
    • /
    • 2000
  • Chemical facility system have dangerous elements that can injure the human like an explosion and a fire, gas poisoning by a leakage of the harmful chemical material. In addition to a vibration of the machine occurs the leakage. Therefore, the chemical factory requires for periodic monitoring of the vibration. But, until now, the operator has executed a monitoring of the machine by the senses. So, the diagnostic expert system by which the operator can judge easily and expertly a condition of the machine is developed. This paper describes the structure of diagnostic system and the diagnostic algorithm using fuzzy inference

  • PDF

A Study of Development of a Remote Monitoring Data Acquisition System using TCP/IP Protocol (TCP/IP Protocol을 이용한 원격 감시용 계측 시스템 개발에 관한 연구)

  • 문경록;이주열;김재문
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.173-176
    • /
    • 2002
  • DAS(Data Acquisition System) as a ground support equipment has played a critical role in proving the status of ready-to-fire of a rocket system before launch. But it is hard to implement and place a real-time measuring system in a control room at a long distance from the vehicle. In this paper DAS is introduced by being located at the LEC(Launch Equipment Container)[1], 50 meters away from the rocket and connected to remote monitoring system via fiber optics with TCP/IP protocol by means of client/server algorithm. Therefore real-time data acquisition and storage are guaranteed and a convenient and useful MMI (Man-Machine Interface) can be developed.

  • PDF

Power Tunnel Monitoring and Diagnosis Based On Multiple Attribute Making Decision with Uncertainty (불확실성을 고려한 다중요소 의사 결정기반의 지중전력구 감시 및 진단)

  • Lee, Gi-Hea;Kim, Sang-Tae;Lee, Ji-Hoon;Kim, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.349-350
    • /
    • 2015
  • Traditional power tunnel monitoring and diagnosis system provides simple alert in accordance with limits which set by operator using various field installed various sensor measurements. System's algorithm is too simple and it has uncertainty of sensor with error. In this paper, proposed algorithm give operator verification using installed sensor measurements such as environmental sensors for fire prevention because of cable overheat in the power tunnel.

  • PDF

The effects of work environment monitoring organization's analysts' equipment and chemical substance incident response to the safety management awareness

  • Park, Hyun-A;Choi, Seo-Yeon;Rie, Dong-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.5
    • /
    • pp.97-103
    • /
    • 2017
  • In this paper, we propose a method to investigate the safety consciousness of a analyst incident response. This study conducted a statistical survey on 154 analysts who hired as expert in environment monitoring organizations in South Korea. The results of the analyses showed that respondents had good awareness on the equipment incident response and complied with laboratory safety regulations very well. Secondly, respondents were aware of the importance in the order of equipment incident response, an analytical laboratory incident response, and the cause of a chemical substance associated incident in an analytical laboratory in regarding the regulation compliance for creating a safe laboratory environment and the securement of laboratory safety. Therefore, (it was identified that) it would be necessary to create a safe environment and integrate a safety management system.

FOREST MONITORING PROTOTYPE SYSTEM USING WEB MAPPING TECHNOLOGY

  • Kawahito, Shinobu;Kuroiwa, Kaori;Sobue, Shin-ichi;Ochiai, Osamu
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.793-794
    • /
    • 2003
  • Forest fire monitoring prototype system was developed by National Development Agency of Japan (NASDA) and the Ministry of Agriculture, Forestry and Fisheries of Japan (MAFF) to verify the usefulness of interoperabile system to study new services of Earth observation satellite data distribution for a practical application. In this system, a standard interface of Web based GIS technology, OpenGIS Consortium (OGC) technology, was adopted. This system is also expected to encourage data sharing activities in Digital Asia Network (DAN) as a demonstration system.

  • PDF

A case study of condition monitoring for mold transformers on urban railway transit (도시철도용 몰드변압기 상태감시를 위한 사례조사 연구)

  • Kim, Do-Yoon;Jung, Ho-Sung;Park, Young;Han, Seok-Youn;Lee, Sang-Bin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.235-240
    • /
    • 2008
  • Since urban railway transit is one of the most essential transportation systems, its power facilities must ensure high reliability and safety. Currently, urban railway operating organizations perform TBM (Time Based Maintenance) on power facilities. However, in order to improve management efficiency and system safety, CBM (Condition Based Maintenance) is preferred. Among various power facilities, mold transformers has been chosen as the object of study since it is widely used for the purpose of minimizing volume and weight, and due to safety against fire. In this paper, various transformer failure cases due to electric, thermal, mechanical and environmental factors have been collected and analyzed. In addition, investigation on national and international condition based maintenance cases and the characteristics of sensors widely used for transformer monitoring has been performed to suggest the optimal condition based maintenance technique for urban railway systems.

  • PDF

A Study on Performance Improvements about Duct of Smoke Control System Combined with Air-Conditioning Equipment (공기조화설비 겸용 제연설비 덕트의 성능개선을 위한 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 2021
  • To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.