• 제목/요약/키워드: Fire line construction

검색결과 39건 처리시간 0.02초

헬기에 의한 산불공중간접진화 방법에 관한 연구 (Study of Indirect Attack Method of Aerial Fire Firefighting by Helicopter on Forest Fire)

  • 배택훈;최연철
    • 한국항공운항학회지
    • /
    • 제24권3호
    • /
    • pp.55-61
    • /
    • 2016
  • Among the method of aerial fire firefighting, the indirect attack is efficiency way to protect main facilities and it is the aerial fire line construction. According to this study is suggested the fire line construction strategy of indirect attack by helicopter suitable Korea forest fire on theory consideration of indirect attack and experience in practical scene. This study defined that main key points of the fire line construction are accuracy, large quantity, and quickness. Main protection facilities are devided as caution area, warning area, danger area and concern area. Also, it suggested stage-by-stsge from 1 step to 3 step for the aerial fire firefighting correspondence strategy and the fire line construction model. I regard that this study's indirect attack method of the aerial fire firefighting of the fire line construction may be understand about indirect attack tactics and application of indirect attack which is assistance to raise of capability of the aerial fire firefighting with effectiveness and efficiency.

산불 공중진화 방화선 구축형태 및 진화방법에 관한 연구 (Study of Aerial Fire Line Construction and Suppression Method on Forest Fire)

  • 배택훈;이시영
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.26-31
    • /
    • 2010
  • 본 연구는 우리나라의 각종 소.중형 및 대형 산불의 공중진화 경험을 바탕으로 산불행태와 헬기의 현장운영을 고려한 산불 공중진화 방화선 구축형태 및 진화방법에 대하여 제안하였다. 산불확산은 현장의 지세, 경사, 바람, 수종 등에 영향을 받으므로 공중진화 방화선을 구축할 때에는 연소방향 및 형태, 강도 등을 분석한 후 진화작업을 실시하여야 하며, 특히 연기로 인하여 시계가 방해 받으므로 안전을 고려해 진화작업을 하는 것이 중요하다. 따라서 본 연구에서는 산불현장 공중진화 경험을 바탕으로 A형에서 M형까지 13개의 산불 공중진화 방화선 구축형태 및 진화방법을 제안하였다.

공조설비의 온라인 유지관리 효과 분석 (An Analysis on the Maintenance Effect of the HVAC System with On-line Management Method)

  • 김용기;이태원;강성주;우남섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.54-59
    • /
    • 2008
  • The poor maintenance and management of HVAC systems finally lead to the shortening of the life expectancy and result in the increase of operating costs and energy consumptions due to low efficiencies. Also, it is essential to try to develop ways to adequately maintain and to use the building facilities efficiently in order to preserve earth environment and the limited resource. In this study, an analysis on the maintenance and management cost for HVAC systems was carried out with the capacity of equipment. Besides, the LCC(Life Cycle Cost) based analysis was carried out to verify the effect of the doing maintenance and management. As the results, the case of the good maintenance and management is able to save LCC to 11 % than the case of the poor method.

  • PDF

내화피복이 생략된 합성보의 구조설계지침 제정을 위한 고찰 (Structural Design Guide Line of Composite Beam)

  • 홍원기;김진민;이경훈;박선치;김점한
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.93-98
    • /
    • 2008
  • As high rise buildings and large span spatial structures are constructed, new composite members and construction techniques are continuously developed. Wide flange steel beam can be easily constructed but the fire proofing protection is necessary and the cost is high. Nowadays environmental pollution of structures is becoming a big issue. The material of fire proofing protection is not allowed to use for structural members in several countries because it cab be a cause of environment pollution. Composite beam is a new hybrid beam system which is not needed a fire proofing protection process. Composite beam has better construction capacity than that of RC system and has more economic advantages than that of wide flange steel beam. In this paper, structural design guide lines of composite beam were provided to apply design and construction.

산불 공중진화 방화선 구축형태에 관한 연구 (Analysis of Aerial Fire Line Construction Type on Forest Fire)

  • 배택훈;이시영
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.443-447
    • /
    • 2010
  • 본 연구에서는 우리나라의 소 중 대형 산불의 공중진화 방화선 구축형태에 대하여 제안하였다. 산불확산은 현장의 지세, 경사, 바람, 수종 등에 영향을 받으므로 공중진화 방화선을 구축할 때에는 연소방향 및 형태, 강도 등을 분석한 후 진화작업을 실시하여야 하며, 공중진화 방화선 형태를 A형에서 M형까지 13개로 제안하였다.

  • PDF

IT를 활용한 공조설비의 온라인 유지관리시스템 개발 (A Development of the On-line Maintenance and Management System for the HVAC system Using IT)

  • 이태원;김용기;강성주;우남섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.48-53
    • /
    • 2008
  • The performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. A major use of building energy management system(BEMS) is for monitoring plant and building's energy consumption. National building management system (N-BMS) presented in this study links buildings into a network group in order to monitor and control the buildings. How to construct the N-BMS was considered to save energy resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

반도체 제조공정의 연기유동에 관한 연구 (A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process)

  • 한수진;강경식
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.

3D/BIM 기반 기존 건축물 실시간 건물 화재 정보 관리 방안 (A Method on Developing 3D/BIM-Based Real Time Fire Disaster Information Management)

  • 배수빈;차희성
    • 한국건설관리학회논문집
    • /
    • 제24권2호
    • /
    • pp.3-12
    • /
    • 2023
  • 건축물에서 발생하는 화재 사고는 주변에서 빈번하게 확인할 수 있는 문제이다. 건축물의 화재사고는 시간의 경과에 따라 인적·물적 자원의 피해가 커지고 대형사고로 이어지게 됨으로 신속한 화재 진압·구조 방안의 모색이 필요하다. 현재 사회적으로도 화재 사고에 관한 관심은 주목되고 있으나 실제 화재 상황에 대처하는 부분에 미흡함이 존재해 안전사고에 관하여 사회가 요구하는 기대치를 충족하지 못하는 실정이다. 이러한 사회의 요구에 맞추어 본 연구는 건물 내 화재로 인한 피해를 최소화하기 위한 신속하고 체계적인 화재 관리 방안을 제시하고 있다. 연구의 목적을 달성시키기 위한 방안으로 아두이노 센서 및 Excel, Revit-Dynamo 툴을 연동하여 새로운 화재정보 관리 시스템을 개발 및 실시간 3D 시각화 Model을 개발하고, 실제 사례에 적용하여 화재 관리의 우수성을 보였다. 추후 활용방안으로 화재 관리 어플리케이션을 제안하여 실시간 스마트 화재 관리시스템에 기여할 수 있다고 기대하는 바이다.

도로의 축광차선 도료 개발을 위한 축광안료 최적 배합비 산정에 관한 연구 (Determination of Optimal Mixing Ratio of Phosphorescent Pigment to Develop Phosphorescent Paint for Road Line Marking)

  • 이영문;김상태;김흥래
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.67-73
    • /
    • 2015
  • PURPOSES : This study was conducted to derive the optimum mixing ratio of phosphorescent pigment for the development of phosphorescent line marking. METHODS: In this study, we utilized a literature review and case study methodology, to describe the domestic and foreign state of practice for the production and mixing of phosphorescent pigment for use in line marking. The optimal mixing ratio was derived by comparing the reduction in luminance over time for the various phosphorescent pigment mixing ratios identified in the literature. In addition, performance and construction characteristics were analyzed using field testing techniques. RESULTS : The results were as follows: 1) the results of the luminance performance standards tests showed that all of the phosphorescence test specimens satisfied the phosphorescent fire protection standard. As the phosphorescent pigment mixing ratio increased, the luminance value increased, 2) the luminance reduction rate was minimum at the mixing ratio of 50%. However, when compared to a mixing ratio 40%, a small difference was recorded, the luminance reduction rate from the mixing ratio of 40% is judged as being converged. Therefore, in view of the economic efficiency, it was determined that the optimal mixing ratio was 40%, 3) as a result of construction on the field, a mixing ratio of 40% was found to have a higher luminance value than the general line marking for up to three hours after sunset, 4) it was found that the phosphorescent line markings without glass beads spraying had a higher luminance value than the phosphorescent line markings with glass beads spraying. CONCLUSIONS : Through the results of the basic experiments of the line markings obtained by blending a phosphorescent pigment, the results could be applied to play an important role in the development of phosphorescent line marking paint technology and in establishing application planning for on-site construction characteristics.

송전용 폴리머애자의 산불 영향 신뢰성 평가 (Reliability Assessment of Forest Fire on EHV Polymer Insulator Strings)

  • 민병욱;신태우;최인혁;최한열;박재웅;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.436-437
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea but polymer insulators which are superior in that they are light weight, explosion proof, impact proof, economical with construction characteristics, have been in use for the 154kV transmission line since 1999 following a worldwide trend towards the reduced weight, simplification and compact usage of new material insulators. However there have been approximately 500 cases of forest fires in Korea, so the transmission lines that for the most part pass through mountainous areas have been highly effected and the highly polymerized compound polymer insulator has raised concern about reliability in cases of exposure to forest fires. Therefore for the reliability assessment of the effect of forest fires on polymer insulators, mechanical and electrical characteristics are analyzed by an artificial flare test device and transmission facility surrounding conditions along with forest fire characteristics are surveyed. In addition to this, actual 90kV energized transmission line was tested with an artificial forest fire and the expanded usage of polymer insulators is presented through the analysis of mechanical and electrical characteristics and physical properties, and a study on the influence of forest fires on polymer insulators.

  • PDF