• Title/Summary/Keyword: Fire investigation system

Search Result 158, Processing Time 0.028 seconds

A Study on Investigation into Actual Condition of Management in Fire Protection System -Apartment Buildings, Shopping Center, Office Buildings- (소방시설 관리실태조사에 관한 연구 -공동주택, 상가건축물, 사무소건축물-)

  • 김홍배;한상민;이영재;조병선
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.70-76
    • /
    • 2001
  • In a daily life these days, the safety and the comfort are considered very important. As the same as other areas, the good maintenance of fire protection systems and the fire drill plans in buildings can minimize the loss of human life and the property in case of fires. In this paper, a survey has been conducted to investigate the maintenance status of the fire protection systems of apartment buildings, shopping center and office buildings. Both practical procedures for checking the systems and for fire drills and strategic plans to minimize the losses in case of fires are suggested by analyzing how well the occupants in the buildings acknowledge the evacuation drills when the fire occurs.

  • PDF

A Study on Fire Risk of Apartment House with Pilotis Structure - Focused on the Fire case of Uijeongbu-si Urban Livig Homes - (필로티 구조의 공동주택 화재 위험성 연구 - 의정부 대봉그린 도시형아파트 화재 사례를 중심으로 -)

  • Choi, Seung-Bok;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • Pilotis are support columns that lift a building above the ground. Thus, they can elevate the lowest floor to the secondfloor level and, in Korea, are used to leav a parking area below multifamily housing. However, if there is a fire in the piloti area, the cars and main entrance door are wrapped in flames. Due to the inflammability of the materials, the combustion of the cars and insulation at the ceiling of the pilotis, having a high heat release rate, can quickly destroy the front entrance of the building and spread heat, flames and a poisonous gas to the stairs and elevator pit. Therefore, the fire can quickly spread to the whole building, putting the lives of the residents in danger. This study was an in-depth accidental case study of the "Uijeongbu Fire Accident" that killed 5 residents and injured 139 others. The study identified the relationships between the fire at the piloti structure of multifamily housing and the vulnerability of this structure and its inherent weaknesses.

New Input Keyword Extraction of Equipments Involved in Ignition Using Morphological Analysis (형태소 분석을 이용한 발화관련 기기의 새로운 입력 키워드 추출)

  • Kim, Eun Ju;Choi, Jeung Woo;Ryu, Joung Woo
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • New types of fire accidents appear or the existing types disappeared because of rapidly changing society. We proposed a methodology of extracting new nouns from fire investigation data each of which is an accident report producted by fire investigators. The new nouns could be used in modifying the existing categories for classifying fire accidents. We analysed morphology of the product names and the ignition summaries using the proposed method for the fire accidents classified as the etc sub-category of the category of equipments involved in ignition. In this paper, we found "dryer" as a new sub-category of the agricultural equipment category and "boiler" in the seasonal appliance category from the product names of the fire accidents. We also extracted the new input keywords of "aquarium" and "monitor" in the commercial facilities category and the video, audio apparatus category from the ignition summaries respectively. Using the four subcategories, we reclassified 548 (14.39%) of 3,808 fire accidents assigned to the etc sub-category.

Thermal Numerical Simulation on Fire Suppression Characteristics through Mobile Mist Spray Nozzles (이동식 미분무수 노즐의 소화 특성에 대한 수치 시뮬레이션)

  • Bae, K.Y.;Chung, H.T.;Kim, H.B.;Jung, I.S.;Kim, C.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.25-33
    • /
    • 2009
  • In the present study, the numerical investigation has been carried out to see the effects of water mist sprays on the fire suppression mechanism. The special-purposed program named as FDS was used to simulate the interaction of fire plume and water mists. This program solves the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The computational domain was composed of a rectangular space dimensioned as $L{\times}W{\times}H=4.0{\times}4.0{\times}2.5\;m^3$ with a mist-injecting nozzle installed 1.0 m high from the fire pool. In this paper, two types of nozzles were chosen to compare the performance of the fire suppression. Numerical results showed that the nozzle, type A, with more orifices having smaller diameters had poorer performance than the other one, type B because the flow injected through side holes deteriorated the primary flow. The fire-extinguishing time of type A was 2.6 times bigger than that of type B.

  • PDF

A Study on the Analysis of Operation Reliability of Fire Doors and Fire Shutters Using Fire Statistical Data (화재통계자료를 활용한 방화문, 방화셔터 작동신뢰성 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.119-120
    • /
    • 2020
  • In order to establish an evaluation method that can quantitatively evaluate the fire safety of existing buildings in Korea, a stochastic approach is needed to consider the extent of damage in the event of actual fire, along with the operation and installation of facilities. Accordingly, as a basic study for the establishment of fire safety assessment methods for buildings, this study aims to analyze the results of safety inspection and the degree of damage caused by the operation of fire doors and fire shutters in order to derive the reliability of fire doors and fire shutters. As a result, the results of inspection of fire shutters and fire doors and the results of operation using fire statisticians are as follows. As a result of the inspection, the positive rate of fire doors was about 82% and 98% of normal operation was derived from the fire investigation.

  • PDF

A Study on Institutional Improvement of Multiple Available Premises (다중이용업소의 제도개선 방안에 관한 연구)

  • Song Yun-Suk;Hyun Seong-Ho;Yoon Myong-O
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.57-63
    • /
    • 2005
  • This study has investigated problem that fire damage and a loss of lives increased continuously in spite of improvement countermeasure enforced since fire accident of multiplex available premises, and has analyzed problem and weakness factor through question investigation in fire prevention administration by space of multiplex available premises and special quality business form. We have proposed institutional improvement of efficient multiplex available premises studying fire fighting safety education and training way about employer or employee with specification of fire prevention administration system, on the basis of such analysis.

Damage Pattern Analysis of Voltage Cabinet Panel due to Flame (분전반의 화염에 의한 소손패턴 분석)

  • Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon;Kim, Man-Geon
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.37-40
    • /
    • 2008
  • This paper deals with damage patterns of cabinet panel for low voltage deteriorated by flame. In order to analyze damage patterns, we used Metallurgical Microscope, x-ray system, and Fourier Transform Infrared spectroscopy. Firstly, Metallurgical microscope was used for analysis of electrical causes, such as electric short and overload Secondly, X-ray system was used for analysis of internal characteristics of circuit breakers. Lastly, Fourier Transform Infrared spectroscopy was used for analysis of damage direction by flame.

  • PDF

Development of New Algorithm for Maximum Power Point Tracking of Photovoltaic system (Photovoltaic 시스템의 MPPT를 위한 새로운 알고리즘 개발)

  • Park, Ki-Tae;Ko, Jae-Sub;Choi, Jung-Sik;Park, Byung-Sang;Chung, Dong-Hwa
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.87-95
    • /
    • 2007
  • This paper is proposed a novel method to approximate the maximum power for a photovoltaic inverter system and tracking method. It is designed for power systems application and utilities. The proposed Maximum Power Point Tracking (MPPT) control has the advantage to provide a new simple way to approximate the optimal or rated voltage, the optimal or rated current and maximum power rating produced by a solar panel and the photovoltaic inverter. And this straightforward method will be named linear reoriented coordinates method (LRCM) with the advantage that Pmax and $V_{op}$ can be approximated using the same variable as the dynamic model without using complicate approximations or Taylor series. Furthermore tracking method is improved over 50% photovoltaic efficiency. This paper is proposed MPPT using LRMC and tracking method using weather condition of domestic moderate program technique. This paper is proposed the experimental results to verify the effectiveness of the new methods.

  • PDF

The Research for the Establishment of Test Method of Durability on Intumescent Coating System (내화도료 내구성 평가 방법 설정에 관한 연구)

  • Choi, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.40-47
    • /
    • 2009
  • Applying fire resistive coating to steel members is one of the general methods to secure fire resistance performance of steel members. And intumescent coating system is currently one of methods giving fire resistance to steel members. Intumescent coating system for fire resistance, however, has undesirable weaknesses that fire resistance performance of steel members is being deteriorated due to cracks and falling-offs of the coverings as time goes after completion of the coverings to the members. So it is necessary to understand changes of the durability and the fire resistance performance of intumescent coating system over a time elapse and to reflect such change properly into the building design and construction. This research is performed to present the test method of durability and the maintenance of intumescent coating system through theoretical investigation of the test method of durability and the guide of maintenance & management of intumescent coating system of several countries, including the Britain, United States, Japan.

Experimental study on the combustion characteristics of titanium alloy (티타늄 합금 폐기물의 연소 특성에 관한 실험적 연구)

  • Lee, Jun-Sik;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • Most titanium alloy waste with cutting oil was discarded without recycling process so that it can be caused by metal and oil fires. However, there is no fire management system and studies on the titanium or titanium alloy waste in spite of high fire risk. The purpose of this experimental study is to identify the fire risk of the titanium alloy waste with cutting oil. We collected the 120g waste which was made in the biomedical titanium alloy cutting process. The waste was burned and conducted thermal image analysis with infrared camera. The experimental results which illustrated the process, characteristics, and trends of fire are presented. Firstly, the cutting oil was burned and partially the titanium alloy waste was burned. The maximum temperature of the fire was more than $650^{\circ}C$ in some specific spots. These results means when a lot of titanium alloy waste with cutting oil was ignited, this fire could connect the titanium fire. In other words, the fire has a flammable liquid fire and combustible metal fire at the same time. The experimental study could be used fire prevention, response, and investigation of the titanium alloy waste.