• 제목/요약/키워드: Fire investigation system

검색결과 159건 처리시간 0.032초

방화범죄의 실태와 그 대책 - 관심도와 동기의 다양화에 대한 대응 - (The Reserch on Actual Condition of Crime of Arson Which Occurs in Korea and Its Countermeasures)

  • 최종태
    • 시큐리티연구
    • /
    • 제1호
    • /
    • pp.371-408
    • /
    • 1997
  • This article is the reserch on actual condition of crime of arson which occurs in Korea and its countermeasures. The the presented problem in this article are that (1) we have generally very low rate concern about the crime of arson contrary to realistic problems of rapid increase of crime of arson (2) as such criminal motives became so diverse as to the economic or criminal purpose unlike characteristic and mental deficiency of old days, and to countermeasure these problems effectively it presentation the necessity of systemantic research. Based on analysis of reality of arson, the tendency of this arson in Korea in the ratio of increase is said to be higher than those in violence crime or general fire rate. and further its rate is far more greater than those of the U.S.A. and Japan. Arson is considered to be a method of using fire as crime and in case of presently residence to be the abject, it is a public offense crime which aqccompany fatality in human life. This is the well It now fact to all of us. And further in order to presentation to the crime of arson, strictness of criminal law (criminal law No, 164 and 169, and fire protection law No. 110 and 111) and classification of arsonist as felony are institutionary reinforced to punish with certainty of possibility, Therefore, as tendency of arson has been increased compared to other nations, it is necessary to supplement strategical policy to bring out overall concerns of the seriousness of risk and damage of arson, which have been resulted from the lack of understanding. In characteristics analysis of crime of arson, (1) It is now reveald that, in the past such crime rate appeared far more within the boundary of town or city areas in the past, presently increased rate of arsons in rural areas are far more than in the town or small city areas, thereby showing characteristics of crime of arson extending nation wide. (2) general timetable of arson shows that night more than day time rate, and reveald that is trait behavior in secrecy.(3) arsonists are usually arrested at site or by victim or report of third person(82,9%).Investigation activities or self surrenders rate only 11.2%. The time span of arrest is normally the same day of arson and at times it takes more than one year to arrest. This reveals its necessity to prepare for long period of time for arrest, (4) age rate of arson is in their thirties mostly as compared to homicide, robbery and adultery, and considerable numbers of arsons are in old age of over fifties. It reveals age rate is increased (5) Over half of the arsonists are below the junior high school (6) the rate of convicts by thier records is based on first offenders primarily and secondly more than 4 time convicts. This apparently shows necessity of effective correctional education policy for their social assimilation together with re-investigation of human education at the primary and secondary education system in thier life. The examples of motivation for arosnits, such as personal animosity, fury, monetary swindle, luscious purpose and other aims of destroying of proof, and other social resistance, violence including ways of threatening, beside the motives of individual defects, are diverse and arsonic suicide and specifically suicidal accompany together keenly manifested. When we take this fact with the criminal theory, it really reveals arsons of crime are increasing and its casualities are serious and a point as a way of suicide is the anomie theory of Durkheim and comensurate with the theory of that of Merton, Specifically in the arson of industrial complex, it is revealed that one with revolutionary motive or revolting motive would do the arsonic act. For the policy of prevention of arsons, professional research work in organizational cooperation for preventive activities is conducted in municipal or city wise functions in the name of Parson Taskforces and beside a variety of research institutes in federal government have been operating effectively to countermeasure in many fields of research. Franch and Sweden beside the U.S. set up a overall operation of fire prevention research funtions and have obtained very successful result. Japan also put their research likewise for countermeasure. In this research as a way of preventive fire policy, first, it is necessary to accomodate the legal preventitive activities for fire prevention in judicial side and as an administrative side, (1) precise statistic management of crime of arson (2) establishment of professional research functions or a corporate (3) improvement of system for cooperative structural team for investigation of fires and menpower organization of professional members. Secondly, social mentality in individual prospect, recognition of fires by arson and youth education of such effect, educational program for development and practical promotion. Thirdly, in view of environmental side, the ways of actual performance by programming with the establishment of cooperative advancement in local social function elements with administrative office, habitants, school facilities and newspapers measures (2) establishment of personal protection where weak menpowers are displayed in special fire prevention measures. These measures are presented for prevention of crime of arson. The control of crime and prevention shall be prepared as a means of self defence by the principle of self responsibility Specifically arsonists usually aims at the comparatively weak control of fire prevention is prevalent and it is therefore necessary to prepare individual facilities with their spontaneous management of fire prevention instead of public municipal funtures of local geverment. As Clifford L. Karchmer asserted instead of concerns about who would commit arson, what portion of area would be the target of the arson. It is effective to minister spontaveously the fire prevention measure in his facility with the consideration of characteristics of arson. On the other hand, it is necessary for the concerned personnel of local goverment and groups to distribute to the local society in timely manner for new information about the fire prevention, thus contribute to effective result of fire prevention result. In consideration of these factors, it is inevitable to never let coincide with the phemonemon of arsons in similar or mimic features as recognized that these could prevail just an epedemic as a strong imitational attitude. In processing of policy to encounter these problems, it is necessary to place priority of city policy to enhancement of overall concerns toward the definitive essense of crime of arson.

  • PDF

재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구 (Development of Electric safety monitoring system for reducing the electrical fire at traditional market)

  • 김기현;이상익;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

설문조사를 이용한 국내 소방 구급자동차의 안전성과 효율성 측면에서의 비교 분석에 관한 연구 (A Study on the Comparative Analysis of Fire-Fighting Ambulances about the Aspects of Safety and Efficiency using the Question Investigation)

  • 신동민;김승용;한용택
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.44-53
    • /
    • 2015
  • 본 연구는 119구급차 유형별 구조와 기능상의 문제점을 파악하여 구급차 내부 디자인을 보다 안전하고 효율적으로 개선하기 위한 조사연구이다. 4개 시 도의 구급대원 755명을 대상으로 2007년 영국 National Patients Safety Agency (NPSA)에서 개발한 환자 안전을 위한 미래 구급차에 관한 보고서와 이와 관련된 문헌고찰을 통해 수정 보완한 도구를 이용하였다. 설문지는 일반적 특성, 소방 구급차 내 안전성과 효율성 증진을 위한 디자인 개선을 위한 항목으로 구성되었다. 자료는 설문지를 전자우편 또는 직접 배포하여 수집하였으며, 수집된 자료는 SPSS 20.0 프로그램을 사용하여 통계처리하였다. 또한, 일반적 특성은 빈도분석, 백분율로, 구급차 내부 디자인 개선관련 항목은 카이제곱검증을 이용하여 분석하였다. 연구결과, 승합차 개조 소방구급차에서는 내부공간이 좁은 문제와 화물차 개조 구급차에서는 승차감의 개선이 이루어져야 함을 도출하였다. 또한, 구급요원의 안전벨트와 구급요원의 처치 위치의 개선이 필요함을 알 수 있었다. 향후, 이와같은 결과를 토대로 소방 구급자동차의 많은 개선이 필요함을 제시한다.

고온에서 하이브리드 섬유보강 콘크리트의 성능 (Performance of Hybrid Fiber Reinforced Concrete at Elevated High Temperature)

  • 원종필;박경훈;박찬기
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.325-333
    • /
    • 2008
  • 본 연구에서는 강섬유와 서로 다른 직경 및 길이를 가진 폴리프로필렌섬유를 혼합한 하이브리드 섬유보강 콘크리트의 압축강도, 수축균열 및 고온에서 화재저항성을 평가하였다. 압축강도, 쪼갬인장강도, 휨시험 및 수축균열저항성을 평가하기 위하여 실시하였으며 또한 400$^{\circ}C$, 600$^{\circ}C$, 800$^{\circ}C$ 및 1,200$^{\circ}C$에 노출 후 물리 역학정 특성을 평가하기 위하여 표면관찰, 질량손실 및 잔류압축강도 시험을 실시하였다. 시험 결과 하이브리드 섬유보강 콘크리트는 역학적 성능, 수축균열저항성 및 화재저항성을 향상시켰으며 온도 변화에 따른 콘크리트의 성능 저하는 온도가 $600\sim800^{\circ}C$의 범위일 때 가장 컸다.

재난안전사법경찰제도의 발전 방안 연구 (Study on the Development of Disaster Safety Judicial Police System)

  • 김정래;김종북;박형진;권현석;김승남;이시영
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.163-174
    • /
    • 2019
  • 본 연구는 경기도와 강원도지역 시·군에서 현재 재난안전특별사법경찰로 활동하고 있는 일반직 공무원을 대상으로 현 운영상의 문제점에 대한 실태조사 및 개선방안을 도출하기 위해 설문조사 방식으로 이루어졌다. 재난안전특별 사법경찰의 전문성, 수사 환경 및 인적요인 등 현 운영 실태를 분석하여 제도의 운영상 문제점과 개선방안 및 활성화 방안을 도출하였다. 나날이 복잡하고 다양해지는 전문 업무영역 범죄예방에 대처하기 위해서는 재난안전특별사법경찰상을 재정립하는 방향을 제시하였다.

동일본 대지진 당시 일본의 비상 발령 및 주민대피에 관한 실태 조사와 시사점 도출: 문헌조사연구 (Implications of Emergency Alert and Resident Evacuation in Japan during the Great East Japan Earthquake: Literature Survey Study)

  • 이재영;김윤희;엄영호
    • 한국재난정보학회 논문집
    • /
    • 제17권3호
    • /
    • pp.500-511
    • /
    • 2021
  • 연구목적: 후쿠시마 원자력 발전소 폭발사고 발생 당시의 재난상황, 주민보호를 위한 비상발령 상황, 주민 피난 상황에 대한 조사와 더불어 당시 주민보호 시스템에 있어서 제기된 문제점 및 조치사항에 대한 조사를 수행함으로서, 국내 원자력 재해를 대비한 주민 피난 대책 수립 과정에서 검토해야만 하는 시사점을 도출하고자 한다. 연구방법: 동일본 대지진 직후부터 현재까지 일본의 국가, 국회, 지자체 및 관련기관으로부터 발행된 보고서를 중심으로 문헌조사를 수행하였다. 연구결과: 후쿠시마 원자력발전소 폭발사고 발생 당시의 주민의 피난과정에서 도출된 문제점과 대응방안에 대한 조사 결과를 통하여 국내의 방사능 재해 대책 수립과정에 있어서 검토해야만 하는 사항을 도출하였다. 결론: 검토 사항을 크게 4가지로 분류하였으며 각 분류에 따른 상세 검토사항을 제시하였다.

공공건축물의 신재생에너지 적용과 에너지 사용량 분석 (Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings)

  • 이용호;서상현;김형진;조영흠;황정하
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

델파이 기법을 활용한 화재피난 시나리오 개선 연구- 모바일 어플리케이션과 재실자 심리를 중심으로 - (A Study on the Improvement of Fire Evacuation Scenario Using Delphi Technique -Focus on The Mobile Application and psychology-)

  • 이상기;김성현
    • 서비스연구
    • /
    • 제12권2호
    • /
    • pp.23-37
    • /
    • 2022
  • 본 연구에서는 화재가 발생했을 때, 화재감지시스템과 연동된 모바일 어플리케이션의 도움을 받아 재실자들이 안전하게 피난할 수 있는 기존의 김태완 외3명(2018)이 제안한 서비스 시나리오를 토대로 1950년 RAND사가 개발한 다양한 전문가의 경험적 지식을 통한 문제해결을 하는 기법인 델파이 조사(Delphi Method)를 통해 좀 더 현실적인 시나리오를 작성하여 피난심리나 행동에 도움이 될 수 있는 모바일 자극을 접목하여 시나리오를 고도화하는 것이 최종 목적이다. 또한 제작되어지는 시나리오가 일반적인 건물의 구조와 동선까지 고려하여 좀 더 현실적으로 만들기 위해 전문가 시나리오검증과 델파이 기법을 적용하여 기존 시나리오에서 불필요하거나 현실적으로 실현이 어려운 부분을 제외 하였다. 연구 결과 1차 델파이 조사에서 화재경보 시에 보일 수 있는 주요 심리로 꼽혔던 것은 의구심, 안전불감, 경각심이었으며, 2차 델파이 조사의 결과를 분석한 결과 내용타당도(CVR)와 수렴도, 합의도를 모두 만족하는 것은 의구심과 경각심 두 가지 심리가 도출되었다. 최종적으로 이 내용을 적용하여, 모바일 어플리케이션의 도움을 받아 화재 대응 단계에서 피난하는 시나리오를 작성하였다. 본 연구를 통해서 화재발생시 재실자들의 피난률을 높이기 위해 이를 활용하는 방법을 적용할 수 있을 것이다.

논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구 (Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure)

  • 이호형;최판규;이상돈;허원호;조종복
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.189-199
    • /
    • 2019
  • 본 연구에서는 배연댐퍼 또는 제트팬과 같은 방재시설이 설치된 터널형 구조물(방음터널)에 대하여 방재시설 가동에 따른 화재연기의 거동을 수치해석적으로 고찰하고 해석결과를 비교 검토하여 다음과 같은 결론을 얻었다. 화재차량 천장부 개방 유무에 따라 방음터널 내 화재양상이 확연하게 달라지는 것을 확인하였으며, 방음터널의 주요 자재인 PC와 PMMA의 임계온도를 초과하지 않는 것으로 나타났다. 또한 배연댐퍼의 설치간격에 따른 해석결과, 방음터널 내 발생하는 최대 온도가 미설치시에는 최대 $552^{\circ}C$인 반면, 설치간격이 50 m인 경우에는 $405^{\circ}C$로 나타났으며, 제트팬 가동 여부에 따른 해석결과, 방음터널 내 발생하는 최대 온도는 제트팬 미가동시에는 $549^{\circ}C$인 반면, 가동시에는 $86^{\circ}C$로 나타나 화재시 피난환경과 방음자재보호에 있어 매우 유리한 환경을 조성할 것으로 예상되며, 향후 다양한 목적을 가진 터널을 대상으로도 이러한 기초연구의 활성화가 필요할 것으로 사료된다.

재래시장 상가 분전반 및 전기안전감시시스템 개발 연구 (Development of Electric Safety Monitoring System and Cabinet Panel for Traditional Markets)

  • 김기현;이상익;신성수;배석명
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.123-128
    • /
    • 2010
  • 재래시장의 전기재해로 인한 재산 및 인명 피해를 줄이기 위하여 재래시장 특성을 고려한 상가 분전반에서 재래시장에 사용되는 전기설비의 상태(과부하, 누전, 아크발생, 전력량, 화재발생 지수 등)를 원격으로 모니터링할 수 있는 전기안전감시시스템을 개발하였다. 개발된 전기안전감시시스템의 신뢰성과 안전성을 확인하기 위해 분전반 실험 및 전기안전감시시스템의 운영 방향을 토대로 재래시장 전기안전감시시스템 Test-Bed를 구성하였다. 본 논문은 추후에 재래시장 실증 부하들의 운영에 따른 안전성과 신뢰성을 검증하기 위한 자료로 사용될 것이다.