• Title/Summary/Keyword: Fire investigation data

Search Result 115, Processing Time 0.028 seconds

A Study on the Analysis and Classification of Types and Causes of Railway Accidents (철도사고 위험분류 및 원인분석에 관한 연구)

  • Park Chan-Woo;Park Joo-Nam;Wang Jong-Bae;Cho Yun-ok
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.599-604
    • /
    • 2005
  • As a public transportation possible to convey a large quantity, the railway is safe and keeps time, but it has hazards to cause a disaster if the accidents such as collision, derailment, and fire occur. So advanced countries carry out System Safety Plan with various program activities which have connected orders to maintain or improve safety level by finding hazards, evaluation, taking measures and practice, and improving problems. Especially they systematically manage hazards to cause railway accidents and the factors which possibly threat safety, using national classification of risk and causes with analysis of the related data such as establishing accident/incident data and safety regulations/standards. As executing railway safety regulations, domestic railway is currently trying to improve railway safety management system. The research of classification system of accidents/incidents is one thing to make railway safety management systems better. In this research, we reviewed hazardous factors of railway systems and classification of the causes as the beginning of system safety management, and we conducted study on development of railway accident classification based on findings of this research. The results are able to be used in identifying hazards and activities of systemic safety management at the step of railway accident report and investigation.

  • PDF

Development and Use of Data for Chemical Risk Assessment (화학물질 유해성 평가를 위한 정보의 작성 및 활용)

  • Rim, Kyung-Taek;Kim, Hyun-Ok;Kim, Young-Kyo;Cho, Hae-Won;Ma, Yong-Seok;Lee, Kwon-Seob;Lim, Cheol-Hong;Kim, Hyeon-Yeong;Yang, Jeong-Seon
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.91-101
    • /
    • 2007
  • The new chemicals are developed and circulated without the verified toxicity data. So, the accidents and occupational diseases, such as explosion, fire, suffocation about deadly poisons etc. are frequently to workers. Classifications of chemicals suited with guideline and an offer of correct chemical information data are the molt important thing for the establishment of suitable chemical management system. The GHS (Globally Harmonized System of classification and labeling of chemicals) is based with the chemical classifications and unification plan. The warning symbol and phrases are established for improvements of chemical information data system. According to these unified and improved systematic form of data, and the chemical information data, the workplaces will be presented many chemical safety and risk data correctly. In this paper, we will present constructions and accomplishment contents-based chemical management of workplace through development of chemical information data and the nice using for new chemical investigation and risk assessment of chemicals in workplaces.

Mechanical Deterioration of Overhead Transmission Lines by Forest Fires (산불에 의한 가공 송전선로의 기계적 열화 특성)

  • 김영달;김성덕;심재명;정동화;강지원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.26-34
    • /
    • 2000
  • The considerations for remaining life of ACSR (Aluminum Stranded Conductors Steel Reinforced) in transmission lines have become gradually important to hold reliability and stability of power supply. The remaining life of ACSR exposed to the atmosphere for a long period may rely on deterioration caused by environmental indices such as atmospheric corrosion, galvanic corrosion, crevice corrosion and fatigue corrosion. One of reduction of useful life in overhead transmission lines built on the ridge of mountain is often caused by forest fires.This paper deals with investigation of strength deterioration performance of ASCR due to fires through several testing and analyzing data for tension load and extension of blazed ACSR. Test samples are ACSR 480[$\textrm{mm}^2$] conductors, which are artificially fired to regular durations. Mechanical properties such as tension load and extension for fired ACSR conductors are tested and estimation functions for mechanical performances corresponding to fire duration are determined. As a result, it can be verified that both tension load and extension of ACSR are reduced by increasing fire duration. Hence, it is obvious that ACSR due to forest fires may lead to mechanical deterioration.

  • PDF

Subsea Responses to the BP Oil Spill in the Gulf of Mexico (멕시코만의 BP사 오일유출 해저 대책에 대한 분석)

  • Choi, Han-Suk;Lee, Seung-Keon;Do, Chang-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.90-95
    • /
    • 2011
  • On April 20, 2010, a well control event allowed hydrocarbon (oil and gas) to escape from the Macondo well onto Deepwater Horizon (DWH), resulting in an exploration and fire on the rig. While 17 people were injured, 11 others lost their lives. The fire continued for 36 hours until the rig sank. Hydrocarbons continued to flow out from the reservoir through the well bore and blowout preventer (BOP) for 87 days, causing an unprecedented oil spill. Beyond Petroleum (BP) and the US federal government tried various methods to prevent the oil spill and to capture the spilled oil. The corresponding responses were very challenging due to the scale, intensity, and duration of the incident that occurred under extreme conditions in terms of pressure, temperature, and amount of flow. On July 15, a capping stack, which is another BOP on top of the existing BOP, was successfully installed, and the oil spill was stopped. After several tests and subsea responses, the well was permanently sealed by a relief well and a bottom kill on September 19. This paper analyzes the subsea responses and engineering efforts to capture the oil, stop the leaking, and kill the subsea well. During the investigation and analysis of subsea responses, information was collected and data bases were established for future accident prevention and the development of subsea engineering.

A Study on the Non-evaporating Diesel Spray Characteristics as a Function of Ambient Pressure in Constant Volume Combustion Chamber (정적챔버에서 분위기 압력에 따른 비증발 디젤분무특성 연구)

  • Jeon, Chung-Hwan;Jeong, Jeong-Hoon;Kim, Hyun-Kyu;Song, Ju-Hun;Chang, Young-June
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.645-652
    • /
    • 2010
  • The aim of this investigation was study on the non-evaporation diesel spray characteristics injected through a common-rail diesel injector under various ambient pressure. The diesel spray was investigated with observation of macroscopic characteristics such as spray tip penetration and spray cone angle by the shadowgraph and the image processing method. The numerical study was conducted using a computational fluid dynamics code, AVL-FIRE. The breakup models used were WAVE model and standard $k-{\varepsilon}$ turbulence model was applied. The numerical study used input data which spray cone angle and fuel injection rate was achieved by Zeuch's method. Comparison with experimental result such as spray tip penetration was good agreement. Distribution of droplet diameter were conducted on four planes where the axial distances were 5, 15, 39 and 49mm respectively downstream from the orifice exit.

Investigation on Minimum Film Boiling Point of Highly Heated Vertical Metal Rod in Aqueous Surfactant Solution (계면활성제 수용액 내 고온 수직 금속봉의 최소막비등점에 대한 연구)

  • Lee, Chi Young;Kim, Jae Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.9
    • /
    • pp.597-603
    • /
    • 2017
  • In this study, experiments were conducted on the MFB(minimum film boiling) point of highly heated vertical metal rod quenched in aqueous surfactant solution at various temperature conditions. The aqueous Triton X-100 solution(100 wppm) and pure water were used as the liquid pool. Their temperatures ranged from $77^{\circ}C$ to $100^{\circ}C$. A stainless steel vertical rod of initial center temperature of $500^{\circ}C$ was used as a test specimen. In both liquid pools, as the liquid temperature decreased, the time to reach the MFB point decreased with a parallel increase in the temperature and heat flux of the MFB point. However, over the whole present temperature range, in the aqueous Triton X-100 solution, the time to reach the MFB point was longer, while the temperature and heat flux of the MFB point were reduced when compared with pure water. Based on the present experimental data, this study proposed the empirical correlations to predict the MFB temperature of a high temperature vertical metal rod in pure water and in aqueous Triton X-100 solution.

Effects of Vicarious Trauma on Mental Health in Firefighters (소방 공무원에서 간접 외상이 정신 건강에 미치는 영향)

  • Baik, Jun-Hyuck;Jung, Young-Eun;Chae, Jung-Mi;Myong, Jun-Pyo;Yim, Hyeon-Woo;Cha, Jeong-Ho
    • Anxiety and mood
    • /
    • v.6 no.1
    • /
    • pp.65-70
    • /
    • 2010
  • Objectives : Indirect contact with trauma may occur when a person empathically listens to detailed descriptions, exposing the person to intense emotional pain from trauma victims. Although less severe than direct trauma, indirectly traumatized persons may experience the same fear, rage, and despair as direct trauma victims. This phenomenon has been variously termed vicarious trauma, traumatic countertransference, burnout, compassion fatigue, and secondary traumatic stress. Using a psychiatric symptoms questionnaires, this study investigated the effects of indirect exposure to co-worker's trauma on the mental health of firefighters who had not directly experienced traumatic events in the previous year. Methods : We administered self-report questionnaires, such as the Impact of Event Scale-Revised (IESR) and Alcohol Use Disorder Identification Test (AUDIT), to firefighters working at two fire stations in a metropolitan city. We analyzed 188 of 232 collected surveys, after excluding falsely entered data (28 cases) and questionnaires by directly-traumatized victims (16 cases). Results : Alcohol consumption and posttraumatic stress disorder (PTSD) symptoms, as determined by the AUDIT and IES-R, were significantly higher in the indirectly-traumatized group. The ratio of high-risk members scoring higher than 23 in IES-R was larger in the indirectly traumatized group, although this was not statistically significant. Conclusion : Alcohol consumption was significantly higher in the indirectly traumatized group. This group also included more members at high risk for PTSD. Further research, with a larger group of indirectly traumatized firefighters and ongoing investigation of PTSD development and other psychiatric symptoms, is needed.

Hazard Evaluation of Minimum Ignition Energy by Electrostatic Voltage in Suspended Dust Particles (부유 분진의 정전압에 의한 최소착화에너지 위험성평가)

  • Han, Oue-Sup
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.359-365
    • /
    • 2021
  • We investigated experimentally the ignition characteristic of dust and the hazard evaluating for electrostatic discharge. The ignition energy experiments were performed on sample dusts such as PE(HD), PE(LD), PMMA using the MIKE-3 apparatus. The formation of flame during the ignition of PE(HD) dust clouds occurred after the delay time of about 8 ms, and the flame kernels were not observed in center of ignition occurrence area. The voltage increased with increasing the number of dust dispersions and the increase rate of measured voltage with dust concentration was the highest in the order of PMMA, PE(LD) and PE(HD). For the effect of dispersion condition on the voltage in PE(HD) dust, the results were obtained that the voltage increased as the number of dispersions increased and as the concentration increased under the same dispersion number. The safety voltages to prevent fire and explosions by electrostatic ignition were estimated that PE(HD), PE(LD)-1, PE(LD)-2, and PMMA were 2.58, 44.72, 25.82, and 8.16 kV, respectively. We proposed the method for estimating the minimum ignition energy by using the measured voltage data for efficient investigation of electrostatic ignition hazard.

Development of Electric Safety Monitoring System and Cabinet Panel for Traditional Markets (재래시장 상가 분전반 및 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.123-128
    • /
    • 2010
  • In this paper, in order to reduce the electric disaster damage which is caused by with electric equipment of traditional markets, we developed cabinet panel and the electric safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electric safety monitoring system and the actual condition investigation about electrical equipment of traditional market. This paper will be used with the data for an actual demonstration project after reinforcing problems which are occurred to operation of traditional market actual loads.

The Lightning Impulse Properties and Breakdown Voltage of Natural Ester Fluids Near the Pour Point

  • Choi, Sun-Ho;Huh, Chang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.524-529
    • /
    • 2013
  • Recently, researchers have become interested in natural ester fluids, as they are an environmentally friendly alternative to mineral oils. Natural ester fluids are a natural resource made from plants; they have higher biodegradability, flash, and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester fluids also have a higher pour point, viscosity, and water content. These characteristics can hamper circulation and impair the electrical properties of an oil-filled transformer. A large amount of data has been accumulated over the years in regards to mineral insulating oil involving dielectric breakdown voltage and lightning impulse tests. However, natural ester fluids have not had their electrical properties sufficiently characterized. In this paper, we present an investigation into the characteristics of the electrical discharge development in natural ester fluids and in an oil-filled transformer near the pour points. The experiment results show that the electrical properties decreased according to a decrease in the ambient temperature and freezing time. It was found that the pour point and water content of natural ester fluids have a significant effect on the electrical properties.