• Title/Summary/Keyword: Fire growth rate

Search Result 105, Processing Time 0.027 seconds

A Study on the Fire Safety Design and Predicting Fire Behavior Using Compartment Fire Test (단일화재실험을 통한 화재성상예측 및 건축구조물의 화재안전 설계에 관한 연구)

  • Yoon, Ung-Gi;Seo, Dong-Goo;Kim, Dong-Eun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.107-108
    • /
    • 2013
  • In this study, combustibles investigation and fire growth rate experiment were performed for predicting initial fire behavior in buildings. Combustibles investigation was performed for residential buildings, which is most frequently affected by fire in Korea. Spatial characteristics and combustibles properties were separately investigated, and occupied area and layout characteristics of combustibles were identified to produce general layout models. Of the layout models, room was selected for fire test of a single compartment. From this test, fire propagation for each combustible was identified, which was delayed compared to the summed heat release rate of a single combustible.

  • PDF

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test (룸코너 시험기의 발열량 측정에 대한 불확도 산정)

  • Noh, Kwang-Chul;Kim, Chi-Hoon;Lee, Seung-Chul;Lee, Duck-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • In fire test, accurate heat release rate measurements provide important information to define the fire safety characteristics of products. The calculation of heat release rate depends on the errors of measuring parameters in experimental set-up. In this study, the uncertainty factors of heat release rate in the room corner test facility, which is installed at Korea Railroad Research Institute, were analyzed. Through the fire testings for the KTX interior materials, the uncertainties of heat release rate were calculated. Results showed that uncertainty was high in the initial stage of fire test and gradually decreased with the growth of fire. The oxygen concentration was a major factor contributing to the combined relative standard uncertainty.

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.

The Study on the Fire Characteristic of Sandwich Panel by SBI(Single Burning Item) (SBI(Single Burning Item)을 이용한 샌드위치패널의 화재특성 연구)

  • Kim, Jung-Hyun;Kim, Heoung-Youl;Lim, Young-Soo;Lee, Seung-Han
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.493-500
    • /
    • 2010
  • 본 연구에서는 EN 13823 기준을 적용한 시험방법인 SBI(Single Burning Item)을 이용하여 스티로폼 샌드위치패널의 화재특성에 대한 실험을 실시하였다. 현재 국내에서는 샌드위치패널 화재특성 평가방법으로 ISO 5660-1(콘칼로리미터 시험방법)과 KS F 2271(난연성시험)이 사용되고 있지만 이러한 시험방법들은 시험 스케일과 시험편 및 가열조건의 한계점 등을 보이고 있다. 따라서 본 연구에서는 1세트를 3개로 하여 총 9개의 75mm 두께인 스티로폼 샌드위치 패널을 이용한 실험을 실시하였다. 이를 통해 공학적인 화재 물성 값인 FIGRA(FIre Growth RAte, kW/s), SMOGRA(SMOke Growth RAte, m2/s2)등을 측정하였다.

  • PDF

A Basic Study on the Fire Experiment of a Single Area for Fire Safety Design. (단일구획실험을 통한 화재안전설계에 관한 기초적 연구)

  • Kim, Dong;Yoon, Ung-Gi;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.110-111
    • /
    • 2013
  • This research studies in the field of domestic fires are an issue in many scientific fire research as a research method to validate the domestic environment and ISO-9705 housing on the basis of experiments in virtual space by making a single fire compartment space for conducting experiments and Appearance of a fire occurring within each flammable Heat Release Rate analysis was carried out mainly. Placed within the space of one flammable HRR calculated as the sum of the number of single-room fire experiments conducted and the results compared with the value in comparing the conduct of fire locations and fire load within the building area of the future, the HRR value represents the change in domestic a consideration of the safety of the building is to propose matters.

  • PDF

Mortality in Pine Stand and Vegetation Recovery after Forest Fire (산불발생 후 소나무 피해 및 식생복원 실태분석)

  • Lee, Si-Young;Jun, Kye-Won;Lee, Myung-Woog;Chun, Kun-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.71-79
    • /
    • 2008
  • To find out the effect of the vegetation recovery and the problems of forest land, the researches of the mortality in pine stand and vegetation recovery have been carried out from the burned site. In area which is damaged by fire scar on crown and stem, rate of dead is higher. Where stand growing stocks were totally damaged by crown forest fire, most of vegetation was recovered by sprouts and planted seeds. Vegetation recovery power were depending on the condition of soil depth condition. For the artificial recovery, the damage happened by insects in the planted birches plantation. Rate of growth was somewhat different between Pinus densiflora and Pinus thunbergii in the plantation, because of individual growth rate.

Effect of forest restoration treatment on Abies holophylla growth and soil condition: Focusing on the Daegwallyeong alpine pastures

  • Ju-Eun Kim;Jeong-Hyeon Bae;So-Jin Kim;Ki-Hyung Park;Namin Koo;Won-Seok Kang;YuGyeong Jung
    • Korean Journal of Agricultural Science
    • /
    • v.51 no.1
    • /
    • pp.25-39
    • /
    • 2024
  • This study aimed to determine a method for restoring grasslands to forests in mountainous areas. The study was conducted in an area damaged by trampling due to construction activity and herding. Additionally, there were concerns of hindered tree growth due to the alpine region climate, characterized by the low temperatures, drying, and strong winds. Therefore, forest restoration treatments such as tillage, furrow, and shading were performed to improve growth conditions. From July 2021 to April 2023, soil temperature and moisture were monitored for each treatment plot, and changes in the initial growth and survival rate of Abies holophylla were investigated. Both soil temperature and soil moisture showed significantly higher values during the four seasons in the grassland-furrow treatment plot (p < 0.05). Compared to the grassland-control plot, the average soil temperature in winter was as high as 1.1℃, and the soil moisture in summer was as high as 20.3%. Additionally, the survival rate and relative growth rate were the largest in the grassland-furrow treatment plot. The survival rate was 87.5%, the relative growth rate in terms of height was 0.013, and the relative growth rate in terms of diameter at root collar was 0.023, indicating that furrow treatment had a positive effect on the initial survival and growth of seedlings. These results suggest that furrow treatment may be an appropriate restoration method when implementing forest restoration projects in areas where tree growth is challenged.

The onset of extreme fire behaviour in a mine drift

  • Hansen, Rickard
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.282-290
    • /
    • 2018
  • The onset of extreme fire behaviour in a mine drift with longitudinal ventilation was analysed. A fire in a mine drift with continuous fuel load, involving several separate fires may lead to flames tilted horizontally and filling up the entire cross section. This will lead to earlier ignition, higher fire growth rate, higher fire spread rate and a severe fire behaviour. The focus has been on what changes take place at the onset and signs of the impending phenomenon. It was found that the fire gas temperature at the ceiling level provided a poor indicator. At the downstream far-field region of the fire, the sudden temperature increase at the lowest levels of the cross section and the sudden increase in flow velocities would provide signs of extreme fire behaviour. The corresponding full-scale heat release rates of the experiments at the onset of extreme fire behaviour were found to be very high for mining applications but not necessarily for tunnel fires. The heat release rate threshold for a mine drift with smaller cross-sectional dimensions would decrease considerably, increasing the likelihood of occurrence. The distance between the fuel items will play an important role during the initiation of horizontal flames.

Activation Conditions of Sprinkler Head Considering Fire Growth Scenario (화재성장시나리오에 따른 스프링클러 헤드의 작동조건)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • The aim of this study is to investigate the gas temperature and velocity during sprinkler activation considering the fire growth scenario based on the thermal response model of the sprinkler. The fire source is assumed to have time square fire growth scenarios with a maximum heat release rate of 3 MW. Eight types of standard and fast-response sprinkler heads with an operating temperature range of 65-105 ℃ and a response time index range of 25-171 m1/2s1/2 were adopted. The temperature difference between the gas stream and the sensing element of the sprinkler head decreased as the fire growth slowed down, and the RTI value decreased. The overall gas temperature and velocity conditions predicted using the FDS model at sprinkler activation were in reasonable agreement with those of standard test conditions of the sprinkler head response. However, the sprinkler head could be activated at lower limits of gas temperature and velocity under the current test conditions for a slowly growing fire scenario.