• 제목/요약/키워드: Fire frequency

검색결과 425건 처리시간 0.03초

Multivariate assessment of the occurrence of compound Hazards at the pan-Asian region

  • Davy Jean Abella;Kuk-Hyun Ahn
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.166-166
    • /
    • 2023
  • Compound hazards (CHs) are two or more extreme climate events combined which occur simultaneously in the same region at the same time. Compared to individual hazards, the combination of hazards that cause CHs can result in greater economic losses and deaths. While several extreme climate events have been recorded across Asia for the past decades, many studies have only focused on a single hazard. In this study, we assess the spatiotemporal pattern of dry compound hazards which includes drought, heatwave, fire and wind across Asia for the last 42 years (1980-2021) using the historical data from ERA5 Reanalysis dataset. We utilize a daily spatial data of each climate event to assess the occurrence of such compound hazards on a daily basis. Heatwave, fire and wind hazard occurrences are analyzed using daily percentile-based thresholds while a pre-defined threshold for SPI is applied for drought occurrence. Then, the occurrence of each type of compound hazard is taken from overlapping the map of daily occurrences of a single hazard. Lastly, a multivariate assessment are conducted to quantify the occurrence frequency, hotspots and trends of each type of compound hazard across Asia. By conducting a multivariate analysis of the occurrence of these compound hazards, we identify the relationships and interactions in dry compound hazards including droughts, heatwaves, fires, and winds, ultimately leading to better-informed decisions and strategies in the natural risk management.

  • PDF

Low-Frequency Haptic Interface Developed for Electrical Safety Experience Education

  • Cho, Hyun-Seob
    • 한국정보전자통신기술학회논문지
    • /
    • 제8권1호
    • /
    • pp.75-78
    • /
    • 2015
  • Electric shock due to the increased use of power, equipment accidents, electrical accidents, such as electric fire and also continues to grow. To prevent electric shock accidents, an experience education is more effective than indoctrination education. But an electric shock experience education system required a proper physical stimulation on human body to experience electric shock. In this study, we conducted a study to take advantage of the realistic haptic interface using a low-frequency type experiential learning and prevention education. Results of this study could be applied to an electric shock experience education system.

크린시설동 소음 및 진동 해석 (Research on Noise and Vibration Analysis for a clean facility)

  • 전용한;박노국;이덕수
    • 대한안전경영과학회지
    • /
    • 제19권1호
    • /
    • pp.245-255
    • /
    • 2017
  • This paper is a study to estimate the noise generated by fluid around each machine in the basement and basement facilities that accept major noise factor, pump fluid mechanical equipment installed to evaluate the impact on the real working environment. In particular, the review of the reliability of complementary information and reliability predict the natural frequency for generating a maximum strain when the vibration analysis, and intended to ensure that the design to avoid a natural frequency of the structure, on the basis of the this analysis result to the subject a real building.

The Properties of Open-Ended Meander Slot Antenna and its Applications to Antenna Design

  • Lee, Young-Soon
    • 한국항해항만학회지
    • /
    • 제35권7호
    • /
    • pp.563-568
    • /
    • 2011
  • The various properties such as the electric current distribution, resonant frequency and radiation patterns of open-ended meander slot antenna placed on a small ground plane, are investigated to give the help in performing antenna design. Based upon these characteristics, the designed antenna which is only 22mm($0.06{\lambda}_g$) in height and 31mm($0.09{\lambda}_g$) in width can operate at the 433 MHz with the measured radiation efficiency of 8% and end-fire radiation pattern. These properties make the antenna suitable for the handheld device such as the wireless remote controller.

On the Method for Hot-Fire Modeling of High-Frequency Combustion Instability in Liquid Rocket Engines

  • Sohn, Chae-Hoon;Seol, Woo-Seok;Valery P. Pikalov
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1010-1018
    • /
    • 2004
  • This study presents the methodological aspects of combustion instability modeling and provides the numerical results of the model (sub-scale) combustion chamber, regarding geometrical dimensions and operating conditions, which are for determining the combustion stability boundaries using the model chamber. An approach to determine the stability limits and acoustic characteristics of injectors is described intensively. Procedures for extrapolation of the model operating parameters to the actual conditions are presented, which allow the hot-fire test data to be presented by parameters of the combustion chamber pressure and mixture (oxidizer/fuel) ratio, which are customary for designers. Tests with the model chamber, based on the suggested scaling method, are far more cost-effective than with the actual (full-scale) chamber and useful for injector screening at the initial stage of the combustor development in a viewpoint of combustion instabilities.

전기화재 방지를 위한 AFCI 알고리즘 설계 (AFCI algorithm design for electrical fire protection)

  • 반기종;최성대;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1769-1770
    • /
    • 2006
  • Arc Fault is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional interrupter does not have the arc current interrupt function. Hence, Arc fault circuit interrupter controller is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

대형 판매시설물의 피난안전규정을 위한 재실자 밀도에 관한 현장조사 연구(II) (A Field Study attention: The Population Density in Resident Area and Evacuation Regulation on Sale Facility(II))

  • 이상희;서동구;황은경;황금숙;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.273-276
    • /
    • 2008
  • As the rapid and various changing of social aspects, the structures are getting bigger, higher and more complex. The importance of evacuation is on the rise as increased using frequency of multiplex sale facility and it's high population density. According to the result of a survey with 4 domestic wholesales mart's population density, the average and maximum was 0.41(人/$m^2$) and 0.46(人/$m^2$). considering evacuation dangerousness, the maximum value will be suitable for computation of evacuation capacity and this will be submitted as a basic data for computation of evacuation capacity.

  • PDF

Experimental investigation on thermal behavior, sound absorption, and flammability of natural fibre polymer composites

  • Ravi Kumar, B.;Hariharan, S.S.
    • Structural Engineering and Mechanics
    • /
    • 제76권5호
    • /
    • pp.613-618
    • /
    • 2020
  • Exhausting oil resources and increasing pollution around the world are forcing researchers to look for new, renewable, biodegradable materials to lead sustainable development. The use of fiber reinforced composites based on natural fibres has increasingly begun as prospective materials for various engineering applications in the automotive, rail, construction and aerospace industries. The natural fiber chosen to make the composite material is plant-based fibre, e.g. jute fibre, and hemp fibre. Thermosetting polymer based Epoxy (LY556) was utilized as matrix material and The composites were produced using hand lay-up technique. The fabricated composites were tested for acoustic testing, thermo-gravimetric analysis (TGA) and flammability testing to asses sound absorption, thermal decomposition and fire resistivity of the structures. Hemp fibre composites have shown improved thermal stability over Jute fibre composites. However, the fire resistance characteristics of jute fibre composites are better as compared to hemp fibre composites. The sound absorption coefficient of composites was found to enhance with the increase of frequency.

산림화재의 발생빈도와 발화장소 분석을 통한 산림화재 저감을 위한 방안 도출 (Development of Measures to Reduce Forest Fire by Analyzing the Occurrence Frequency and the Ignition Point of Forest Fire)

  • 이재영;김영민
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2022년 정기학술대회 논문집
    • /
    • pp.439-440
    • /
    • 2022
  • 우리나라 건기에 해당하는 봄철에는 산불화재에 예방에 주의해야 한다. 그러나 안타깝게도 이 시기에는 다양한 언론매체를 통하여 산불화재 피해에 대한 소식을 전해 들어야만 하는 것이 사실이다. 2022년 울진군에서 발생한 산불화재는 국내에서 2000년 동해안 산불에 이어 역대 2번째로 피해 규모가 큰 산불화재이다. 산불화재은 건축화재와 달리 피해면적에 광범위하기에 더욱 주의를 기울여야만 하며, 언론매체를 통한 피해 규모를 살펴보면 산불의 위험성을 증대하는 것처럼 느껴진다. 본 연구에서는 국가화재통계를 이용하여 국내에서 발생하는 산불화재의 발생빈도와 발화장소에 대하여 살펴보았다. 이를 통하여 대규모 산불화재로 인한 피해를 예방하기 위한 방안으로서 화재안전대책 우선순위를 도출하고자 하였다.

  • PDF

진주시 도시시설물별 화재발생 위험도 평가 (The Risk Assessment of the Fire Occurrence According to Urban Facilities in Jinju-si)

  • 배규한;원태홍;유환희
    • 대한공간정보학회지
    • /
    • 제24권1호
    • /
    • pp.43-50
    • /
    • 2016
  • 우리나라의 도시화율은 점점 높아지고 있으며 이에 따라 도시인구 증가와 더불어 다양한 도시시설물들이 급속도로 도시에 집중되고 있는 실정이다. 이에 따라 다양한 재해로 인한 피해가 발생되고 있고 사회재난 중 화재는 교통사고와 더불어 도시에서 가장 많은 피해를 입히고 있다. 2015년 우리나라의 화재발생은 44,432건이 발생하여 253명의 사망자와 4,300억원의 재산피해가 발생하여 다양한 피해 저감 노력에도 불구하고 감소되는 추세를 보이고 있지 않다. 이에 본 연구에서는 국가화재정보시스템과 진주소방서를 통하여 2007년부터 2014년까지 발생한 진주시 화재자료를 수집하였으며 행정자치부의 시설물 현황 DB를 통해 진주시의 화재와 시설물의 군집성을 분석하고 화재위험도를 산출하였다. 그 결과 미국소방기술사회(SEPE:Society of Fire Protection Engineers) 기준에 따른 화재발생빈도에 대한 위험 등급을 4단계로 구분한 경우 가장 높은 A등급으로 업무시설, 위락시설, 자동차시설이 분류되었으며, 그 다음으로 U등급은 단독주택, 공동주택, 교육시설, 판매시설, 숙박시설, 집합시설, 의료시설, 산업시설, 생활서비스시설, EU등급은 기타주택이고, 마지막으로 가장 낮은 BEU등급은 위험물제조시설로 나타났다. 또한 인명피해를 기준으로 한 경우 가장 위험도가 높은 시설물은 위험물제조시설이었고 재산피해를 기준으로 한 경우는 집합시설과 산업시설이 가장 위험도가 높게 나타났다. 이상과 같이 도시에서 발생된 화재를 시설물별로 구분하여 발생빈도, 인명피해, 재산피해에 대해 위험등급을 산정하여 제시함으로서 도시공간에 분포한 시설물에 대한 화재저감대책을 수립하는데 효과적으로 활용할 수 있을 것으로 판단된다.