• 제목/요약/키워드: Fire fighting measure

검색결과 17건 처리시간 0.019초

마그네슘 화재의 효과적인 초기소화를 위한 금속화재용 소화기 활용방안에 관한 연구 (A Measure on the Use of Metal Fire Extinguisher for Effective Early Extinguishment of Magnesium Fire)

  • 남기훈;이준식
    • 한국산업융합학회 논문집
    • /
    • 제24권6_2호
    • /
    • pp.795-800
    • /
    • 2021
  • Magnesium fires require early fire extinguishment due to impulsive and rapid-fire expansion that makes difficult fire fighting. For this reason, efficient early fire fighting and appropriate prevention of fire spread are considered mainly as significant fire extinction measures. However, there is a limit to developing tools for metal fire fighting, such as devices, facilities, and fire extinguishing agents, due to a lack of regulatory instruments in South Korea. It often generates challenges to early fire fighting implementation by fire responders. Thus, the aim of this study is to investigate a measure for securing the efficiency of early fire fighting in magnesium. This study identified the applicability of the metal fire extinguisher used in the United States for magnesium fire through a performance test of a fire extinguishing agent for metal fire. Moreover, we implemented a free burning experiment using magnesium powder to compare varying combustion and extinction process that could occur during applying metal fire extinguishers. Finally, this study suggests measures of the use and application of metal fire extinguishers for magnesium.

국가지정 목조문화재의 소방대책에 관한 실태조사 (The Study for Fire Prevention of Main Wooden Cultural Properties of Korea)

  • 백민호;이지향
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2010
  • 본 연구에서는 문화재청에서 지정한 123개 목조문화재를 대상으로 소방대책을 고려한 실태조사 및 분석을 다음과 같이 실시하였다. 첫째 우리나라 목조문화재의 관리 및 원인별 화재발생현황을 조사하여 정리하였다. 둘째, 123개의 중요목조문화재에 대하여 2008년 8월부터 10월까지 현장조사 및 유관기관 자료조사를 실시하여 문화재의 지정구분, 소재지구분, 해당건축면적, 보유문화재수, 소방시설현황, 소방차의 진입방향, 자위소방대 인원, 방화관리자 선임여부, 소방서와의 거리 및 소요시간 등의 소방대책 마련에 필요한 내용들을 조사 분석하여 중요목조문화재의 기본현황을 정리하였다. 셋째, 위의 조사 자료를 기본으로 123개 중요목조문화재의 화재발생을 고려한 위험도를 살펴보고자 문화재의 내부적 현황과 외부적 현황으로 구분하여 평균지수에 의해 분석하고 우리나라 중요목조문화재의 소방대책수립을 위한 기초자료를 정리하였다.

우리나라 의용소방대의 활성화 방안 고찰 (The Active Measure of the Operation of the Volunteer Fire Brigade in Korea)

  • 정기성
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.138-142
    • /
    • 2009
  • 의용소방대제도는 조선시대부터 조직되어 활동하고 있는 민간자율 소방조직이다. 여러 가지 우여곡절을 겪은 후 일제 통치 시대를 거치면서 1958년 소방법 제정으로 의용소방대가 설치되어 오늘에 이르고 있다. 과거의 소방인력이나 장비가 부족한 시대에 의용소방대는 소방활동에서 중요한 역할을 하였다. 화재진압 보조, 농촌지역에서의 화재초기진화, 산불진화, 사회봉사활동 등을 활발하고 훌륭하게 수행하여 왔다. 그러나 오늘의 소방조직은 국가의 경제력 향상과 국민들의 안전에 대한 의식 증대, 소방방재청의 개청 등으로 비약적인 발전이 이루어졌다. 과거 소방의 부족한 부분을 훌륭히 채워주던 의용소방대의 역할을 재조명하고 새로운 활동영역 등을 모색하여 활성화 할 방안을 강구하고자 한다.

응급구조과 학생 현장실습의 실제와 개선방안 연구 (Study on Reality of Field Practice and Improvements by Students of Dep. of Emergency Medical Technology)

  • 권혜란
    • 한국응급구조학회지
    • /
    • 제6권1호
    • /
    • pp.15-26
    • /
    • 2002
  • As a result of analyzing problems in field practice and its effects, the following conclusions can be obtained. Man students were more satisfied with their choice of this department than woman students and woman students recognized the importance of hospital practice although they felt the need of fire fighting station practice and man students felt the necessity of hospital practice, but they answered the fire fighting station practice was important. Departments of field practice are emergency and nurse departments in hospitals and emergency aid section in fire fighting stations. And it is found that field practice was performed well in relation to major subject. Areas of practice included emergency room, operation room and extensive cure unit and the experience of ambulance was more in fire fighting station than in hospital. Clinical guidance of professor was preferred to once a week and the students answered they felt satisfaction with practice through conference. Answer that field practice was helpful in understanding class was very high as 96.8% and its connection with employment was low as 12.8%. It is found that a proper timing of field practice was winter vacation for hospital practice after completing the second semester of the first year and summer vacation for fire fighting station practice after the first semester of the second year. The most difficult department in field practice was nurse department in hospital because 'respondents were practice students' and administrative department in fire fighting stations because 'they lacked recognition of paramedic'. In making practice diary, 'describing measure results' was difficult most and the respondents wanted to keep the diary in their custody.

  • PDF

비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교 (Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application)

  • 김병혁;정한;김영호
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.

단독주택의 간이스프링클러설비 적용에 관한 연구 (A Study on the Application of Simple Sprinkler Facility at Single Housing)

  • 홍성우;이영재
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.33-41
    • /
    • 2008
  • 현재 국내 단독주택은 소방시설의 설치유지 및 관리운영에 대한 법적규제가 없을 뿐 아니라, 거주자의 자율 화재예방 의식에 의존하고 있어 방재에 취약하고 열악한 실정이다. 따라서 본 연구는 주택화재의 가장 큰 비중을 차지하는 단독주택을 중심으로 화재의 발생현황 및 문제점과 법규적용 및 설계방안을 연구하였으며, 주택화재의 방재대책으로 "건축법 시행령 별표 1"의 용도별 건축물의 종류 중 단독주택은 공동주택과 같이 특정소방대상물로 분류하여 관리토록 하여야 할 것이며, 단독주택에 거주하는 고령자, 장애인등을 고려한 소화기, 경보설비, 주거용 간이스프링클러설비 등의 소방시설 설치를 의무화 하도록 하여야 할 것이다.

대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구 (A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores)

  • 홍성우;이영재
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.20-27
    • /
    • 2002
  • 본 연구는 현재 급속히 확산되고 있는 대형 할인점의 피난대책 및 소방시설 설치기준에 관한 개선방안을 제시하기 위한 것으로 주요 내용은 다음과 같다. -대형 할인매장의 피난대책. -매장의 피난시설 설치의 문제점 및 대책. -매장의 방화구획 설치의 문제점 및 대책. -매장의 옥내소화전 설치의 문제점 및 대책. 연구결과 건축계획시 면적기준에 의해 설치되는 피난계단의 경우 상주인원수에 의해 수량, 설치위치, 규격 등이 결정되어야 할 것이며, 매장 부분의 방화구획 또한 시설물 설치로 인한 장애 및 피난로 확보 차원에서 매장부분에 한하여 설치를 완화하는 대신 스프링클러 설치 기준을 강화하여야 할 것이며, 스프링클러 설치시 자진하여 옥내소화전을 추가 설치하는 경우 소화전은 상품진열 등으로 인하여 사용이 불가능한 부분이 발생하므로 매장부분에 설치되는 옥내소화전은 설치반경을 완화하여 실질적인 소화시설 사용이 가능하도록 하여야 할 것이다.

목조 사찰화재의 유형별 진압대책에 관한 연구 (A Study on Fire Suppression Measures Used in Wooden Temples)

  • 고기봉;이시영;채진
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.10-17
    • /
    • 2012
  • 본 연구에서는 목조 사찰 화재시 펌프(물탱크)차의 현장 도착 가능여부에 따라 사찰화재 유형별 진압대책을 4가지 유형으로 분류하고, 각 유형별 화재진압 전술 및 방법을 도출하였다. 연구결과, 펌프(물탱크)차의 접근 및 소방용수 확보가 가능한 사찰은 일반 건축물화재 진압전술을 적용하지만, 그렇지 않은 경우는 헬기, Water Bag, 연계급수 집중 진압전술, 무선통신을 이용한 소방차 수위 자동전송 System 및 급수낭을 활용하고, 사찰 인근 소방서에 화재진압 장비(동력펌프, 호스, 노즐, 급수낭 등)를 적재한 일반 4륜구동 차량 배치와 A자 사다리를 활용한 진압대책 등이 필요한 것으로 나타났다.

경비업무적 관점에서의 숭례문화재사고 분석과 대책 (The Analysis on the Soongrae-Mun fire and it's improvement measure)

  • 정태황;이충수
    • 시큐리티연구
    • /
    • 제16호
    • /
    • pp.321-338
    • /
    • 2008
  • 숭례문 화재사고는 우리나라의 평시 문화재에 대한 안전문제를 잘 보여주는 것으로, 사고가 발생할 때마다 관련자에 대한 책임추궁과 재발방지를 요구하였지만 근본적인 문제점 개선 없이 유사한 사고가 계속 발생하고 있다. 본 연구는 숭례문화재사고의 원인을 분석하고 이에 대한 대책을 제시함으로써 유사한 사고의 재발을 막고 민간경비업무의 특성에 맞는 효율적인 경비업무에 도움을 주는데 목적이 있으며, 경비업무적인 관점에서 화재사고를 분석하는데 중점을 두었다. 안전학자인 하인리히((H. W. Heinrich)는 그가 주장한 연쇄반응이론에서 대부분의 사고가 사람의 불안전한 행동이나 불안전한 상태와 같은 직접적인 원인에 의해 발생한다고 이야기하지만 직접적인 원인을 근본적으로 제거하기 어렵기 때문에 직접적인 원인을 유발할 수 있는 관리?통제적 원인과 같은 간접적인 원인에 대한 분석이 중요하다. 문화재에 대한 소방관련 법규의 제정이 필요하다는 주장이 제기되고 있으나 문화재 안전을 위하여 문화재에 대한 경비관련 법규도 같이 검토되어야 하며, 법규 제정과 함께 사고방지를 위한 기술적인 대책도 함께 검토되어야 한다. 민간경비업무의 영역과 능력, 책임문제에 대한 한계를 극복하기 위한 전문성 확보와 이를 위한 재투자에 관심을 기울여야 하며, 민간경비의 공익성 확보를 위한 경비회사 스스로의 노력이 필요하다. 아울러 사고로 인해 발생한 손해에 대한 배상문제에 대한 현실적인 검토가 필요하다.

  • PDF

대규모 위락시설의 피난안전성능 평가에 관한 연구 (A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities)

  • 박봉래;공하성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.165-173
    • /
    • 2009
  • 성능위주의 설계가 법제화 되면서 화재 및 피난에 대한 연구가 활발히 진행 중이다. 성능위주설계는 인명의 안전성을 증대 시키는 방향으로 발전되어야 한다. 또한, 성능위주의 설계는 소방분야뿐만 아니라 건축법령에서 정하고 있는 피난에 관한 규정을 포함하여 검토되어야 한다. 본 논문은 성능위주의 설계 시 참고가 될 자료로 제시하기위해 다중이용시설인 광주광역시의 OO나이트클럽을 하나의 모델로 삼아 피난시간을 예측하였다. 이를 위해 우리나라와 외국의 피난에 관련된 규정과 연구논문들을 검토하고, 현장을 방문하여 자료를 수집하였다. 그리고 수집된 자료들을 피난프로그램인 Simulex의 입력 자료로 사용하여 피난시간을 측정하였다. 이 연구의 검토과정 및 결과에서 몇 가지 문제시되는 사항을 발견할 수 있었다.