• Title/Summary/Keyword: Fire events

Search Result 154, Processing Time 0.023 seconds

Action Plan of Security Service against a Fire case in a Tall Building Event (경호행사시 초고층건물 화재 대응방안)

  • Son, Kyung-Hwan
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.37-61
    • /
    • 2014
  • Nowadays the world is threatened because of terrors that take aim at Soft-Targets available and easy to access to the people rather than more secured Hard-Targets. The inspection department of the Presidential Security Service develops and acts a perfect safety plan wherever the President stays so that it is possible to get immediate actions for various contingencies. Some events, in which the President take part, could be held in a lower or higher store in a tall building. Additional to the routine work at this case it is to emphasize on a plan of fire precaution to check the spot and respond to a real fire situation, so that the damage could be minimized. First, the agents of the President Security Service should possess basic knowledge concerning to the fire accidents and be trained on their manuals, even in a busy events plan. An organization, whatever it is, could be improved in that it tries to develop not only the personal abilities, but also education programs of the organization continually. And enhanced abilities of the members lead to the driving force for the advance. The knowledge of fire accident should be able to adapt to the real situation. Second, related to the event, it should be cooperated with the relevant departments, so that it is possible to conduct and control the system. It is urgently required to know that the security event could not be done perfectly with only one part or department. Third, from the time of recognizing of the event it is necessary for the fire department to get an action plan with fire fighting measures, evacuation measures based of the instructions given by the Security Service. Fourth, on the knowledge of the action plan of the fire department the Security Service should inspect the safety activities of the spot and establish the practical operation plan through the fire fighting and evacuation plan. Fifth, the Security Service should share final informations and plan of fire fighting in a high-rise building with the other relevant departments. If not, it could cause a great confusion that could lead to a great damage.

  • PDF

Development of Mid-range Forecast Models of Forest Fire Risk Using Machine Learning (기계학습 기반의 산불위험 중기예보 모델 개발)

  • Park, Sumin;Son, Bokyung;Im, Jungho;Kang, Yoojin;Kwon, Chungeun;Kim, Sungyong
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_2
    • /
    • pp.781-791
    • /
    • 2022
  • It is crucial to provide forest fire risk forecast information to minimize forest fire-related losses. In this research, forecast models of forest fire risk at a mid-range (with lead times up to 7 days) scale were developed considering past, present and future conditions (i.e., forest fire risk, drought, and weather) through random forest machine learning over South Korea. The models were developed using weather forecast data from the Global Data Assessment and Prediction System, historical and current Fire Risk Index (FRI) information, and environmental factors (i.e., elevation, forest fire hazard index, and drought index). Three schemes were examined: scheme 1 using historical values of FRI and drought index, scheme 2 using historical values of FRI only, and scheme 3 using the temporal patterns of FRI and drought index. The models showed high accuracy (Pearson correlation coefficient >0.8, relative root mean square error <10%), regardless of the lead times, resulting in a good agreement with actual forest fire events. The use of the historical FRI itself as an input variable rather than the trend of the historical FRI produced more accurate results, regardless of the drought index used.

Process Hazard Review and Consequence Effect Analysis for the Release of Chlorine Gas from Its Storage Tank (염소저장탱크에서의 가스 누출시 공정위험검토 및 결과영향분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.61-73
    • /
    • 2003
  • Most of the accidents occurred from the chemical plants are related to the catastrophic gas release events when the large amount of toxic materials is leaked from its storage tank or transmitting pipe lines. In this case, the greatest concerns are how the spreading behaviors of leakages are depended on the ambient conditions such as air stability and other environmental factors. Hence, we have focused on the risk assessments and consequential analysis for chlorine as an illustrative example. As appeared in the result, Fire & Explosion Index depicted it a bit dangerous with presenting the comprehensive degrees of hazard 90.7. And as a result of Phast6.0/ALOHA, the trends of each scenario appeared considerably identical although there are some differences in the resulting effects according to the input data for the Gas Model. The consequence analysis is performed numerically based on the dense gas mode. In the future, using more correct input data, material properties, and topographical configuration, the method of this research will be useful for the guideline of the risk assessment when the release of toxicants breaks out.

Analysis of Failure and Electrical Fire for Bolt Induction Heating System Using FTA (FTA를 이용한 볼트 유도가열시스템의 고장 및 전기화재 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Eom, Haneol;Kang, Moon-Soo;Jeong, Cheon-Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.12-19
    • /
    • 2021
  • This paper presents a safety assessment method for FTA-based induction heating systems; the failures and causes of electrical fire are first analyzed for each part and module qualitatively, and methods to manage high probabilities of failure and electrical fire are considered, thereby improving the reliability of the induction heating system. The cumulative importance value (ACC) of the minimal cut set is drawn by setting failure as the top event, and STACK and SMPS are observed to account for about 70% of the induction heating system failures. Thus, intensively managing the basic events contained in the minimal cut set of failures for STACK and SMPS is expected to provide effective and stable operation of the induction heating system. When electrical fire is set as the top event, the STACK percentage is 90%. Accordingly, the current IGBT is changed to a FET to increase the applied voltage and prevent induction heating system failure, and a heat sink plane is installed to prevent FET heating caused by switching, thereby preventing an electrical fire. By classifying the parts and modules of the induction heating system in detail and by applying FTA based on actual failure rates and relevant data, more practical and reasonable results may be expected. Hence, continuous research must be conducted to ensure safety when using induction heating systems.

A Review of Recent Studies about Fire and Warm Needling for De Quervain Syndrome (드퀘르벵 증후군의 온침 및 화침 치료에 대한 최신 연구 동향)

  • Jeon, Seok-Hee;Shin, Jeong-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.222-234
    • /
    • 2021
  • Objectives : The purpose of this study is to examine the efficacy of fire needling and warm needling for De Quervain Syndrome by reviewing clinical studies for recent 10 years. Methods : Randomized controlled trials, non-randomized controlled trials, and case series containing more than 20 cases about fire needling and warm needling for De Quervain Syndrome published since 2011 were searched through four foreign online databases (CNKI, Pubmed, EMBASE, Cochrane Library) and five Korean online databases (OASIS, Science ON, DBPIA, KISS, RISS). The number and characteristics of participants, treatment points and main treatment methods involving other combination treatments, treatment cycle or total periods of treatments, evaluation indices, efficacy, and adverse events were analyzed. Risk of bias of included randomized clinical trials was assessed using a revised tool for assessing risk of bias in randomized trials (RoB 2). Results : A total of 6 randomized clinical trials and 2 case series involving 471 participants were included. Tender point or 'Ashi point' was the most commonly used treatment point, followed by LU4. Treatment frequency ranged from once a day to once a week. One to three outcome measures were used to evaluate the results of the studies, with the efficacy rate the most frequently used, followed by visual analogue scale. Overall risk of bias of all included randomized clinical trials was judged to have some concerns. Conclusions : All selected studies showed that fire needling and warm needling treatments for De Quervain syndrome were more effective than other clinical methods or acupuncture treatments. However, as the number of clinical studies is still too small and the risk of bias of the studies is not low, it is believed that more systematic and objective studies should be conducted.

A Study on the Necessity of Psychological First Aid for Firefighters (소방공무원의 심리적 응급처치 필요성에 관한 연구)

  • Ju-Hyun Kim;Sang-Hyuk Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.385-390
    • /
    • 2023
  • The purpose of this study is to study the need for psychological first aid for stress of fire officials. a 1:1 in-depth interview with 10 paramedics to solve the research problem. Through interviews, the policy on the need for psychological first aid to improve the mental health of firefighters was proposed as follows by analyzing the working environment of paramedics, post-traumatic stress experience, and psychological first aid experience. First, fire officials need to be assigned to the site to educate in advance about post-traumatic stress and the resulting physical symptoms before being exposed to traumatic events. Second, fire officials should provide psychological first aid at an appropriate time after exposure to trauma cases. Third, it is necessary to supplement the manpower and institutional devices that will specialize in mental health work. Fourth, for customized professional medical services and psychological support suitable for fire officials, it is necessary to link fire-fighting complex healing centers and national firefighting hospitals.

A Systematic Review of the Variables Related to Post-Traumatic Stress Disorder in Firefighters (소방공무원의 외상 후 스트레스 장애 관련변인에 관한 체계적 문헌고찰)

  • Kang, Min-Ju;Kim, Young-Hwa;Han, Seung-Woo
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.164-172
    • /
    • 2019
  • This study examined the Post-Traumatic Stress Disorder (PTSD)-related variables of firefighters through a systematic literature review. Electronic databases were searched, including RISS, National Assembly Library, NDSL, KmBase. The search terms were PTSD, Post-Traumatic Stress, Post-Traumatic Stress Disorder and Firefighter. Eleven studies from 146 references screened were included. All studies were non-experimental and correlational analyses. The positive correlation factors were age, duration of work, traumatic events, frequency of mobilization, number and strength of traumatic events experienced, work burden, coping method, D-type personality, depression, and anger rumination. The negative correlation factors were resilience, social support, self-esteem. To improve the mental health of firefighters in the future, professional intervention programs should be constructed to improve resilience, social support, and self-esteem, which are protective factors of PTSD.

he Influence of Posttraumatic Stress on Suicidal Ideation in Firefighters : Cognitive Emotion Regulation as a Moderator (소방공무원의 외상 후 스트레스가 자살생각에 미치는 영향 - 인지적 정서조절의 조절효과-)

  • Kim, Sung-Jung;Yook, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.92-101
    • /
    • 2018
  • This study investigated the impact of post-traumatic stress of the fire-fighting officers who are exposed to traumatic events repeatedly on suicide and attempted to verify the moderating effect of cognitive emotion regulation in the relationship between post-traumatic stress and suicidal ideation. For this investigation, this study measured Post-traumatic stress Diagnostic Scale, Korean Beck scale for Suicidal Ideation, Cognitive Emotion Regulation Questionnaire. The research results are as follows. First, Post-traumatic stress, suicidal ideation, adaptive cognitive emotion regulation, and maladaptive cognitive emotion regulation were correlated. second, A hierarchical regression analysis was conducted in order to examine the moderating effect of cognitive emotion regulation in the relationship between post-traumatic stress and suicidal ideation, and as a result, it was found that a sub-factor of cognitive emotion regulation, adaptive cognitive emotion regulation had a moderating effect in a group of persons with low post-traumatic stress, while maladaptive cognitive emotion regulation had a moderating effect in a group of persons with high post-traumatic stress. These results, this study discussed the necessity of follow-up studies, in addition to its academic and clinical implications.

Design and Implementation of Prototype Anti-disaster Remote Control Robot Model using Smart Phone (스마트폰을 이용한 방재용 원격 조정 로봇의 프로토 타입 모델 설계 및 구현)

  • Choi, Sung-Jai
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.221-227
    • /
    • 2014
  • This paper presented a design which was a minimized remote control robot. This remote control robot was created for preventing life damage from conflagrations, nuclear events and HF gas accidents. This robot's system based smart phone that had camera and GPS systems. When fire came out, The robot figured out that how big fire was, where the fire was started and various aspects of situations. And The robot broadcasted the informations to smart phone using mobile application and wi-fi camera. By doing these, the fire mans could more accurate and be easier to plan a strategy for saving life. The body of robot are 2 parts. One is a car and the other one is a remote controller. By the power, 1step to 10steps, of grabbing remote controller could change the car's speed to move. Also, The prototype robot was already confirmed its utility itself.

Numerical Study on Auto-ignition and Combustion Emissions Using Gasoline/Ethanol Surrogates (휘발유/에탄올 혼합연료의 자연발화 및 연소배기가스 특성에 관한 수치적 연구)

  • Lee, Eui Ju
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.1-6
    • /
    • 2016
  • More than five thousands transportation fires occurannually in Korea and the resulting destruction of property and loss of life is huge and results in traffic and environmental pollution. The recent development of automobile technology such as the hybrid concept and use of bio fuels makes fire protection even more difficult due to a lack of understanding of the new adapted system including vehicle engines. In this study, a numerical simulation was performed on a PSR (perfectly Stirred Reactor) to simulate an automobile engine and to clarify the effect of gasoline/ethanol surrogates as a fuel. The temperature, NOx and soot emissions were predicted to decrease with increasing ethanol content, but that of unburned hydrocarbons was found to increase dramatically. The result will provide not only the basic thermal characteristics for engines and their after-treatment systems, but also make it possible to assess the potential for fire events in these systems when an ethanol mixed fuel is used in gasoline vehicles.