• 제목/요약/키워드: Fire evacuation assessment

검색결과 66건 처리시간 0.031초

Evacuation Safety Assessment of Elderly and Children in High-rise Hotels in China

  • Yuanyuan Zhang;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.227-236
    • /
    • 2024
  • Chinese high-rise hotels are large in size, densely populated, and have a lot of combustibles. Once a fire occurs, the fire and smoke spread rapidly, and once a fire accident occurs, it is easy to cause a large number of deaths. Fires have a greater impact on special populations such as elderly and children who move slowly. At present, research mainly focuses on the impact of high-rise building structures on evacuation consequences, but there is very little research on the safety evacuation consequences of elderly people and children in high-rise hotels. This paper focuses on the elderly and children living in high-rise hotels in China. We studied three scenarios in which the elderly and children were placed on high floors, middle floors, and low floors. For the above three scenarios, use pathfinder software for simulation, According to the simulation results, when the elderly and children are mainly concentrated in the lower floors (2nd and 3rd floors), the evacuation time is the shortest, 147 seconds. The evacuation time for the elderly and children on the middle floor (6th and 7th floors) is the longest, at 191.5 seconds. Compared to being placed on high floors, safely staying on low floors for all ages reduces evacuation time by 44.5 seconds and improves evacuation efficiency by 23.24%. The final safety evacuation plan is that in daily safety management, hotels should arrange elderly and children occupants on lower floors as much as possible to reduce the total evacuation time and improve personnel evacuation efficiency. This has great guiding significance in the safety management of high-rise hotels.

철도터널 화재 시 피난개시시간지연 및 화재성장곡선이 정량적 위험도에 미치는 영향 (Effects of evacuation delay time and fire growth curve on quantitative risk for railway tunnel fire)

  • 유지오;김효규;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제20권5호
    • /
    • pp.809-822
    • /
    • 2018
  • 철도터널의 방재시설 설계 시 성능위주설계의 일환으로 화재위험을 정량적으로 평가하는 정량적 위험도평가기법이 도입되어 적용되고 있다. 그러나 각종 위험인자가 위험도에 미치는 영향을 검토하기 위한 연구는 부족한 실정이다. 이에 본 연구에서는 피난개시 시간지연(210~873초) 및 화재성장곡선(1량 화재, 1량 화재지속, 화재중첩)이 정량적 위험도 평가에 미치는 영향을 검토하기 위해서 모델터널(연장: 15 km, 경사도 1.5%, 단면적 $57m^2$, 단굴 양방향 터널)을 대상으로 위험도 평가를 수행하였으며, 다음과 같은 결과를 얻었다. 시나리오(270개)에 대한 분석결과, 사망자는 주로 화재연기의 이동방향과 동일한 방향으로 대피하는 경우가 발생하고 있으며, FED가 0.3을 초과한 후에는 최대 10분 이내에 최대인원이 사망하는 것으로 나타났다. 위험도가 비교적 낮은 범위에서는 피난연결통로간격 및 피난개시시간, 화재성장곡선이 위험도에 영향을 미치는 것으로 나타나고 있으나, 위험도가 한계치에 도달하는 조건에서는 이들의 영향이 거의 없는 것으로 나타났다. 특히 본 연구에서는 피난연결통로의 간격이 1,500 m 이상인 경우에는 피난개시시간지연의 축소나 화재강도 및 화재지속시간의 감소효과가 거의 나타나지 않는 것으로 평가되었다.

건축물화재시의 피난안전에 관한 평가기술에 대한 사례조사 (A Case Study on the Evaluation Technique of Evacuation Safety in Building Fire)

  • 권영진;이병흔
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.115-116
    • /
    • 2020
  • Recently, due to fires in high-rise residential and commercial buildings and apartments in Ulsan and Busan, the issue of evacuation safety in the event of a building fire is being closely watched. In the evacuation safety design for these building fires, it is important to secure evacuation routes considering the spatial characteristics of the building or the characteristics of the occupants and to take measures to protect the evacuation routes in order to ensure the safety of the occupants in the event of a fire. Although simulation is mainly used in Korea to assess the safety of evacuation, there is a big difference in that the Building Standards Act provides tools that can be calculated more than simulation in neighboring Japan. In addition to the evaluation method, which is called the "Building Law Assessment Methods" in Japan, the research team considered that it is important to know the process of evaluation in future domestic research, and investigated the contents of the evaluation process and wanted to apply it first to domestic buildings in the future.

  • PDF

아크릴로니트릴 누출에 따른 독성, 복사열 및 외부영향에 의한 아파트의 성능위주설계 방안 (Performance Based Design Plan for Apartment that Reflects External Effects from Toxicity and Radiant Heat Due to Acrylonitrile Leakage)

  • 오승주;한상훈;공하성
    • 대한안전경영과학회지
    • /
    • 제26권2호
    • /
    • pp.65-77
    • /
    • 2024
  • This study aims to present a performance based design for apartments through evacuation safety assessment and damage impact assessment due to acrylonitrile leakage. In the evacuation safety evaluation, ASET was analyzed as 25 min or more and 60 min or less when the ventilation rate was once per hour, and RSET was 22.6 min. Evacuation safety is satisfied when the number of ventilation per hour is less than 1, so it is necessary to design the number of ventilation to be 1 or less. In the damage impact assessment, the 0% structural collapse rate due to overpressure was measured to be between 71m and 90m, and the 0% fatality rate due to radiant heat was measured to be between 136m and 353m. Therefore, maintain a safe distance of 353m or more.

화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석 (The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder)

  • 김종윤;전용한
    • 벤처창업연구
    • /
    • 제10권6호
    • /
    • pp.253-260
    • /
    • 2015
  • 본 연구에서는 화재 시뮬레이션인 FDS와 피난 시뮬레이션인 Pathfinder를 이용하여 건물의 중앙제어실을 화재발생 지점으로 설정하여 화재안전성 평가 연구를 수행하였다. 먼저 화재시뮬레이션을 이용하여 시간의 경과에 따른 가시거리 분포, 온도분포, CO의 농도분포 등의 정량적 결과를 도출 하였으며, 이 결과를 토대로 피난시뮬레이션을 실시하여 재실자들의 피난시간을 계산함으로써 최종적인 피난안전성 평가 결과를 도출하였다. 화재 시뮬레이션 결과 가시거리의 분포에 따라 위험도가 증가하기 때문에 이 값을 이용하여 피난시뮬레이션을 실시하였으며 그 결과 최종적으로 127.9초에 모든 인원이 대피하는 결과를 얻을 수 있었다. 수치해석 결과 건물 내 모든 장소에서 피난 소요시간이 피난 허용시간을 초과하지 않는 것으로 분석됨에 따라 대피자의 안전성이 확보되는 것으로 분석되었다. 이러한 안전성 평가의 결과는 최악의 조건인 소방설비의 미작동에 근거한 종합안전성평가로서 실제 화재 발생 시 소방설비와 연계한다면 보다 우수한 피난안전성능이 확보될 것으로 평가할 수 있다.

  • PDF

철도터널에서 위험인자가 정량적 위험도 평가에 미치는 영향 (The effect of a risk factor on quantitative risk assessment in railway tunnel)

  • 유지오;김진수;이동호;신현준
    • 한국터널지하공간학회 논문집
    • /
    • 제17권2호
    • /
    • pp.117-125
    • /
    • 2015
  • 철도터널에 대한 정량적 위험도 평가는 다양한 시나리오를 작성하고 사고발생빈도 및 사고의 결과의 곱으로 위험도를 정량화하는 것이다. 정량적 위험도 평가는 터널제원, 화재특성, 제연방법, 제연과 대피방향의 관계 등 다양한 인자에 의해서 영향을 받는다. 이에 본 연구에서는 터널연장(2, 3, 4, 5, 6 km) 및 경사도(5, 15, 25‰)를 변수로 하여 제연방법 및 제연과 대피방향의 관계가 정량적 위험도 평가에 미치는 영향을 검토하였다. 이 결과로 복선터널 단면(단면적 $97m^2$)에서는 열차화재시 열차중 화재차량의 위치와 무관하게 제연반대방향으로 대피하는 것이 가장 효과적인 것으로 나타났다. 또한 이와 같은 조건에서 기계환기시 위험도지수가 자연환기 보다 약 1/10까지 감소하는 것으로 평가되었다.

화재위험도 평가 Tool에 의한 물류창고 공사장 적용성 검증에 관한 연구 (Study on Verification of Applicability for a Warehouse Construction Site using a Fire Risk Assessment Tool)

  • 서용구;민세홍
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.673-688
    • /
    • 2023
  • 연구목적: 공사 중에 발생하는 화재는 빈도는 적으나 그 피해가 크다. 최근 물류유통산업의 성장으로 신축하는 물류창고의 공사장이 증가하고 있어 연구대상으로 선정하고 화재예방을 정량적으로 접근하기 위해 화재위험도 평가 Tool의 개발을 통해 공사현장의 재난을 줄이고자 연구를 진행하였다. 연구방법: 공정에서 진행되는 작업을 분류하여 연소의 3요소에서 제어가 어려운 공기(산소)를 제외한 가연물과 점화원을 등급별로 구분하고, 피난안전성을 추가로 대입하여 종합적인 화재위험평가 Tool을 객관적으로 정량화하여 정립하였다. 연구결과: 개발하여 제시한 화재위험도 평가 Tool을 이용하여 화재위험도가 낮은 굴착공사와, 화재위험도가 중간정도인 설비공사, 화재위험도가 높은 마감공사를 샘플링하여 결과값(CGI)을 도출하였다. 결론: 본 연구에서는 건설현장에서 화재발생 위험도를 평가할 수 있는 Tool의 개발로 위험도 평가에 따른 물적조건(가연물)과 에너지조건(점화원)을 제어하여 구체적인 예방대책의 수립과 피난안전성의 평가를 가능하게 하였다. 향후 건설현장의 화재위험도 평가Tool의 적용을 통해 위험을 줄일 수 있는 공정의 계획 수립과 소방설비의 적응성을 평가하는 기준으로 제공되길 기대한다.

지하철 승강장에서 열차 화재시 제연모드에 따른 화재 안전성 평가 연구 (A study on the evaluation of fire safety according to the ventilation mode in a train fire at the subway platform)

  • 류지오;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제22권3호
    • /
    • pp.293-310
    • /
    • 2020
  • 본 연구에서는 지하철 승강장에서 화재가 발생하는 경우, 제연모드에 따른 위험도를 정량적 위험도 평가기법에 따라서 비교하여 안전확보에 가장 효과적인 제연모드를 제시함을 목적으로 한다. 이를 위해 전형적인 지하철 승장장을 모델로 하여 제연모드별로 대피개시간 및 화재발생열차의 위치에 따른 화재발생 시나리오를 작성하고, 시나리오별로 화재발생률(F)을 산정하고 화재해석과 대피해석을 수행하여 사망자수(N)를 정량적으로 추정하였다. 시나리오별 사고발생률(Frequency)과 사망자수(N:Fatalities)를 추정하여 F/N 선도로 작성하고 이를 사회적 위험도 평가기준과 비교하여 화재 안전성을 평가하였으며, 다음과 같은 결론을 얻었다. 정거장 열차화재 시 인명안전을 위해서는 최대 600 s 이전에 대피가 개시되어야 하며, 정거장 양단배기 시스템이 없는 승강장에서는 승강장 공조시스템을 급기로 운영하여 승강장을 가압하는 것이 대피안전성 확보에 유리한 것으로 나타났다. 승강장 열차화재시나리오에 따른 F/N선도를 작성하여 사회적 위험도 평가기준과 비교한 결과, 제연을 하지 않는 경우에는 한계기준을 상당히 초과하며, 양단배기를 수행하고 승강장을 가압운전모드에서 운영하는 제연모드가 대피안전에 가장 효과적인 것으로 나타났다.