• Title/Summary/Keyword: Fire escape safety

Search Result 116, Processing Time 0.02 seconds

Estimation of Safety in Railway Tunnel by Using Quantitative Risk Assessment (QRA를 이용한 철도터널 방재 안전성 평가)

  • Kim, Do-Sik;Kim, Do-Hyung;Kim, Woo-Sung;Lee, Du-Hwa;Lee, Ho-Seok
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.357-367
    • /
    • 2006
  • Recently, as the construction of new railway and the relocation of existing line increase, tunnel structures grow longer. The railway fire accidents in long tunnel bring large damages of human life and disaster. The interest of safety in long tunnel have a growing and the safety standard of long tunnel is tightening. For that reason, at the planning of long tunnel, the optimum design of safety facility in long tunnel for minimizing the risks and satisfying the safety standard is needed. For the reasonable design of long railway tunnel considering high safety, qualitative estimation for tunnel safety is required. In this study, QRA (Quantitative Risk Assessment) technique is applied to design of long railway tunnel for assuring the safety function and estimating the risk of safety. The case study for safety design in long railway tunnel is tarried out to verifying the QRA technique for two railway tunnels. Thus, the inclined and vertical shaft for escape way and safety facilities in long tunnel are planned, and the risks of tunnel safety for each case are estimated quantitatively.

A study on use of quantitative risk analysis on life safety performance for the effect of fixed fire fighting system at road tunnel fires (정량적 위험성 평가를 활용한 도로터널 화재시 물분무 소화설비의 피난 안전 효과 연구)

  • Park, Kyung-Hwan;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.1-22
    • /
    • 2012
  • This paper tried to verify whether the fixed fire fighting system (FFFS) that is installed in road tunnel improves evacuation performance or not. Verification was performed according to the Disaster Prevention Facilities Installation and Management Guide at Road Tunnel. Twenty seven different fire scenarios were set up for the verification and the cases that FFFS was installed were compared with the cases that FFFS was not installed. The result of the comparison showed that the average equivalent death was reduced in 26 cases out of 27 cases when water spray extinguishing system was installed. It was confirmed that the risk when was not installed was unacceptable in Hong Kong and the Netherlands. On the other hand, it was confirmed that the risk was reduced to as low as reasonably practicable (ALARP) when was installed. The cumulative frequency of average death in case with FFFS was compared against the frequency of death without FFFS: death of one or more is about 50 times less; 10 or more is about 100 times less; and the death of more than 100 is four times less. It was verified that FFFS makes improved conditions to escape from the fires in road tunnel.

A Study of Burn Accidents in Children towards Developing a Program for Prevention (어린이 화상사고의 실태와 예방대책 프로그램 개발에 대한 연구)

  • Han, Jeong-Seok;Seo, Mi-Hye
    • The Korean Nurse
    • /
    • v.36 no.4
    • /
    • pp.61-74
    • /
    • 1997
  • This study is a descriptive study which was done to examine the circumstances surrounding burn accidents in children in order to develop a burn prevention program. The subjects for the study were the mothers of 107 children admitted to two burn specialty hospitals in seoul and the mothers of 172 healthy children attending day care or kindergarten. The tool used in the study was developed by the researchers, pretested and refined. Cronbach's alpha was 0.72. Data collection was done between November 1995 and April 1996. Statistically analysis was done using SAS Version 6.04 and the data was analyzed using test, chi square, regression and logistic analysis. A suumary of the results shows the following : Eighty percent of the children in both groups lived in nuclear families but comparatively more of the children with burn accidents lived in apartments. More of the parents in the group of healthy children had university education and held white collar or professional jobs, while the parents of the children with burn accidents were slightly younger than the parents of the healthy children. but not significantly younger. A significantly greater number of families of children with burn accidents had more than one child and the characteristics of the children with burn accidents that they were more frequently boys, either first or last born and very active. Most of the burn accidents occurred in fall or winter. sometime between noon and midnight and the majority occurred in the home and were caused by hot liquid. In 86% of the cases emergency care was not given at home but the child was brought to the hospital emergency unit. Most of the burns were second degree or greater. involved the arms or legs. required admission, and 41.5% occurred when the parents were preparing or eating meals. In a test of knowledge of preventive measures, the mothers of children who had suffered burn accidents scored slightly higher than the mothers who had no experience with burn accidents, but this was not statistically significant. As to what to do in the case of a fire, the mothers of the healthy children had more knowledge about who to notify. but 70% of the mothers in both groups did not know how to escape from the house if it was of fire. 80 to 96% did not know what do to in case of a fire, such as rolling if clothes were on fire. 80% did not know what emergency care to give for a burn, and 74 to 87% did not know when it is appropriate to try to put out a fire. It can be concluded from this study that. since the results show that the most frequent situation which resulted in burn accidents was when the parents were not aware of the danger of burns or were not paying attention to the child. and when there were no protective devices to prevent burns. and that accidents most frequently occurred at home. the most effective way of preventing accidents is to develop in the parents a "safety mind", Since burn accidents in children are usually more severe than in adults. the physical. emotional. psychological and social damage is greater. In order to develop and awareness of this in the general public. the use of mass media. books and pamphlets and other educational media that provide education on prevention of burn accidents need to be utilized.

  • PDF

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

Requirements of Improvement on Personal Protective Equipment and Experiences Exposed to Accidently High Risk Circumstance while Firefighting: A Questionnaire Study (화재진압 중 소방관의 돌발 고위험상황 노출 경험과 개인보호구 개선요구사항 실태조사)

  • Lee, Hyo-Hyun;Kim, Siyeon;Kim, Do-Hee;Kim, Do-Hyung;Lee, Joo-Young
    • Journal of Korean Living Environment System
    • /
    • v.24 no.5
    • /
    • pp.549-561
    • /
    • 2017
  • We conducted a nationalwide questionnaire to investigate accidental experiences and injuries at flashover or flame-fire for active firefighters in the line of duty. A total of 794 firefighters participated in this survey (764 males, 27 females, and 3 respondents; $39.2{\pm}8.4yr$ in age, $173.7{\pm}5.1cm$ in height, $73.4{\pm}8.6kg$ in body mass). The results showed that high risk circumstances the most frequently experienced while firefighting in Korea was flashover followed by backdraft, rollover and flameover. At the high risk circumstances the most frequently-experienced injuries were bruise, stabs and burns. Firefighters hoped to reduce the total mass of personal protective equipment (PPE), improve the mobility of the PPE and dexterity of protective gloves, so that they could escape from the high risk circumstances as fast as possible. In particular, requirements for improvement on protective gloves were greater than those on other PPE. The present study suggested that the need for improvements on the current firefighters' PPE to cope with emergency high risk situations in terms of PPE mass reduction and mobility.

Performance Evaluation of Advance Warning System for Transporting Hazardous Materials (위험물 운송을 위한 조기경보시스뎀 성능평가)

  • Oh Sei-Chang;Cho Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.15-29
    • /
    • 2005
  • Truck Shipment Safety Information, which is a part of the development of NERIS is divided into Optimal Route Guidance System and Emergency Response System. This research is for establishing an advance warning system, which aims for preventing damages(fire, explosion, gas-escape etc.) and detecting incidents that are able to happen during transporting hazardous materials in advance through monitoring the position of moving vehicles and the state of hazardous materials in real-time. This research is peformed to confirm the practical possibility of application of the advance warning system that monitors whether the hazardous materials transport vehicles move the allowed routes, finds the time and the location of incidents of the vehicles promptly and develops the emergency system that is able to respond to the incidents as well by using the technologies of CPS, CDMA and CIS with testing the ability of performance. As the results of the test, communication accuracies are 99$\%$ in freeway, 96$\%$ in arterial, 97$\%$ in hilly sections, 99$\%$ in normal sections, 96$\%$ in local sections, 99$\%$ in urban sections and 98$\%$ in tunnels. According to those results, the system has been recorded a high success rate of communication that enough to apply to the real site. However, the weak point appeared through the testing is that the system has a limitation of communication that is caused in the rural areas and certain areas where are fewer antennas that make communication possible between on-board unit and management server. Consequently, for the practical use of this system, it is essential to develop the exclusive en-board unit for the vehicles and find the method that supplements the receiving limitation of the GPS coordinates inside tunnels. Additionally, this system can be used to regulate illegal acts automatically such as illegal negligence of hazardous materials. And the system can be applied to the study about an application scheme as a guideline for transporting hazardous materials because there is no certain management system and act of toxic substances in Korea.

  • PDF