• Title/Summary/Keyword: Fire detection sensor

Search Result 149, Processing Time 0.026 seconds

Composite Gas Measurement System using NDIR Method (NDIR 방법을 이용한 복합 가스 측정 시스템)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • The current study was conducted to develop a portable composite gas detector allowing the detection of both $CO_2$ and $CH_4$ gases by means of the Non Dispersive Infra-Red (NDIR) method. The gas detector is configured to radiate infrared waves using infrared lamps, where the wavelength of the infrared light is reduced due to absorption throughout the chamber, and this reduction (absorption) is detected by the absorption detector, before being converted and amplified to a 3.5V~6V electrical signal, providing as accurate a measurement as possible. The conventional singe sensor method measures the relative measurement by absorbing only specified wavelengths of infrared radiation, which in the case of gas detection leads to problems with accuracy due to the lack of a reference sensor when detecting light with a wavelength of only $4.26{\mu}m$. The dual sensor employed in this study provides a comparative measurement between the reference value derived from the wavelength of $3.91{\mu}m$, which is not influenced by other gas sources, and the measurement value derived from the wavelength of $4.26{\mu}m$, in order to reduce the errors and enhance the reliability, thereby allowing low power consumption for portable devices and multi-gas detection for both $CO_2$ and $CH_4$ gases. The portable composite gas detector developed herein provides a measurement rage of 0ppm~5,000ppm for $CO_2$ gas, and 0.5%vol for $CH_4$, which allows the determination of whether the $CO_2$ and $CH_4$ contents in indoor air are less than 1,000ppm or not. The current study established that the composite gas detector can be interlinked with firefighting appliances through portable devices or home automation, and is anticipated to be very effective in fire prevention.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

Fabrication and Experiment of Pneumatic Steel Plate Chamfering Machine and Sensor System for Active Control of Chamfering (면취 공정의 능동 제어를 위한 공압식 자동 강재 면취기와 센서 시스템의 제작 및 실험)

  • Na, Yeong-min;Lee, Hyun-seok;Kim, Min-hyo;Park, Jong-kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.80-86
    • /
    • 2020
  • With the exception of welding activities, it is forbidden to use electricity in shipyards, owing to safety concerns such as the possibility of fire, explosions, and short circuits. In this paper, an automatic chamfering machine using pneumatics is proposed for use in such environments. Customers specify their requirements and the machine derives the corresponding theoretical design conditions. The proposed machine was used to perform 3D modeling, and its suitability and performance were confirmed via cutting experiments of the manufactured device. Two types of sensors may be used in this system: contact and non-contact. In the case of the contact type, an end-stop switch that can recognize the end of the material is installed, and when the machine reaches the end of the material, the end-stop switch is operated to cut off the air pressure. In the non-contact type, four sensors were used: photonic, ultrasonic, metal detection, and encoder. The use of the four sensors was repeated 30 times, and the average error determined. Thus, the optimum sensor was identified.

A Study on Real-Time Detection of Physical Abnormalities of Forestry Worker and Establishment of Disaster Early Warning IOT (임업인의 신체 이상 징후 실시간 감지 및 재해 조기경보 사물인터넷 구축에 관한 연구)

  • Park, In-Kyu;Ham, Woon-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.5
    • /
    • pp.1-8
    • /
    • 2021
  • In this paper, we propose the construction of an IOT that monitors foresters' physical abnormalities in real time, performs emergency measures, and provides alarms for natural disasters or heatstroke such as a nearby forest fire or landslide. Nodes provided to foresters include 6-axis sensors, temperature sensors, GPS, and LoRa, and transmit the measured data to the network server through the gateway using LoRa communication. The network server uses 6-axis sensor data to determine whether or not a forester has any signs of abnormal body, and performs emergency measures by tracking GPS location. After analyzing the temperature data, it provides an alarm when there is a possibility of heat stroke or when a forest fire or landslide occurs in the vicinity. In this paper, it was confirmed that the real-time detection of physical abnormalities of foresters and the establishment of disaster early warning IOT is possible by analyzing the data obtained by constructing a node and a gateway and constructing a network server.

An Analysis on the Deployment Methods for Smart Monitoring Systems (스마트 모니터링 시스템의 배치 방식 분석)

  • Heo, No-Jeong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.55-62
    • /
    • 2010
  • Monitoring systems are able to report certain events at region of interest(ROI) and to take an appropriate action. From industrial product line full of robots to fire detection, intrusion detection, smart grid application, environmental pollution alarm system, monitoring system has widely used in diverse industry sector. Recently, due to advance of wireless communication technology and availability of low cost sensors, intelligent and/or smart monitoring systems such as sensor networks has been developed. Several deployment methods are introduced to meet various monitoring needs and deployment performance criteria are also summarized to be used to identify weak point and be useful at designing monitoring systems. Both efficiency during deployment and usefulness after the deployment should be assessed. Efficiency factors during deployment are elapsed time, energy required, deployment cost, safety, sensor node failure rate, scalability. Usefulness factors after deployment are ROI coverage, connectivity, uniformity, target density similarity, energy consumption rate per unit time and so on.

A Study on u-CCTV Fire Prevention System Development of System and Fire Judgement (u-CCTV 화재 감시 시스템 개발을 위한 시스템 및 화재 판별 기술 연구)

  • Kim, Young-Hyuk;Lim, Il-Kwon;Li, Qigui;Park, So-A;Kim, Myung-Jin;Lee, Jae-Kwang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.463-466
    • /
    • 2010
  • In this paper, CCTV based fire surveillance system should aim to development. Advantages and Disadvantages analyzed of Existing sensor-based fire surveillance system and video-based fire surveillance system. To national support U-City, U-Home, U-Campus, etc, spread the ubiquitous environment appropriate to fire surveillance system model and a fire judgement technology. For this study, Microsoft LifeCam VX-1000 using through the capturing images and analyzed for apple and tomato, Finally we used H.264. The client uses the Linux OS with ARM9 S3C2440 board was manufactured, the client's role is passed to the server to processed capturing image. Client and the server is basically a 1:1 video communications. So to multiple receive to video multicast support will be a specification. Is fire surveillance system designed for multiple video communication. Video data from the RGB format to YUV format and transfer and fire detection for Y value. Y value is know movement data. The red color of the fire is determined to detect and calculate the value of Y at the fire continues to detect the movement of flame.

  • PDF

A Study on Fault Detection Monitoring and Diagnosis System of CNG Stations based on Principal Component Analysis(PCA) (주성분분석(PCA) 기법에 기반한 CNG 충전소의 이상감지 모니터링 및 진단 시스템 연구)

  • Lee, Kijun;Lee, Bong Woo;Choi, Dong-Hwang;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • In this study, we suggest a system to build the monitoring model for compressed natural gas (CNG) stations, operated in only non-stationary modes, and perform the real-time monitoring and the abnormality diagnosis using principal component analysis (PCA) that is suitable for processing large amounts of multi-dimensional data among multivariate statistical analysis methods. We build the model by the calculation of the new characteristic variables, called as the major components, finding the factors representing the trend of process operation, or a combination of variables among 7 pressure sensor data and 5 temperature sensor data collected from a CNG station at every second. The real-time monitoring is performed reflecting the data of process operation measured in real-time against the built model. As a result of conducting the test of monitoring in order to improve the accuracy of the system and verification, all data in the normal operation were distinguished as normal. The cause of abnormality could be refined, when abnormality was detected successfully, by tracking the variables out of the score plot.

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

An Origin-Centric Communication Scheme to Support Sink Mobility for Continuous Object Detection in IWSNs (산업용 무선 센서망을 이용한 연속개체 탐지에서 이동 싱크 지원을 위한 발원점 중심의 통신방안)

  • Kim, Myung-Eun;Kim, Cheonyong;Yim, Yongbin;Kim, Sang-Ha;Son, Young-Sung
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.12
    • /
    • pp.301-312
    • /
    • 2018
  • In industrial wireless sensor networks, the continuous object detection such as fire or toxic gas detection is one of major applications. A continuous object occurs at a specific point and then diffuses over a wide area. Therefore, many studies have focused on accurately detecting a continuous object and delivering data to a static sink with an energy-efficient way. Recently, some applications such as fire suppression require mobile sinks to provide real-time response. However, the sink mobility support in continuous object detection brings challenging issues. The existing approaches supporting sink mobility are designed for individual object detection, so they establish one-to-one communication between a source and a mobile sink for location update. But these approaches are not appropriate for a continuous object detection since a mobile sink should establish one-to-many communication with all sources. The one-to-many communication increases energy consumption and thus shortens the network lifetime. In this paper, we propose the origin-centric communication scheme to support sink mobility in a continuous object detection. Simulation results verify that the proposed scheme surpasses all the other work in terms of energy consumption.

A Traffic Aware Demand-Wakeup MAC(TADW-MAC) Protocol for Wireless Sensor Networks (무선 센서 네트워크에서 트래픽에 적응적인 Demand-Wakeup MAC 프로토콜)

  • Kim, Hye-Yun;Kim, Seong-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.180-186
    • /
    • 2017
  • In this paper we propose a traffic aware Demand Wakeup MAC(TADW-MAC) protocol, in which low data delay and high throughput can be achieved, for wireless sensor networks. With the TADW-MAC protocol, the problem of the DW-MAC protocol, which schedules only one packet to deliver during the Sleep period in a multi-hop transmission is resolved. DW-MAC is not adequate for the applications such as object tracking and fire detection, in which busty data should be transmitted in a limited time when an event occurs [6-8]. When an event occurs, duty cycle can be adjusted in the TADW-MAC protocol to get less energy consumption and low latency. The duty cycle mechanism has been widely used to save energy consumption of sensor node due to idle listening in wireless sensor networks. But additional delay in packet transmission may be increased in the mechanism. Our simulation results show that TADW-MAC outperforms RMAC and DW-MAC in terms of energy efficiency while achieving low latency.