• Title/Summary/Keyword: Fire data analysis

Search Result 777, Processing Time 0.028 seconds

A Classification of the Fire Law related by Building Occupancy for the Comparative System of Fire Protection Performance (방재 성능 비교 시스템 구축을 위한 화재관련 법규의 건축 용도별 분류)

  • Shin, Ho-Sub;Suk, Chang-Mok;Cha, Chung-Sook;Han, Ju-Hyung;Kim, Young-Yeon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.25-28
    • /
    • 2008
  • Korean city had been rapid developed through high industrialization and rapid economic growth after the 1970's. The city development process was guaranteed the fulfillment of city function through the city expansion based on New Towns and satellite cities rather than the reformation of existing city. This city expansion caused by degrading of city, being backward and producing many problems. To solve this problems, it was considered the rehabilitation of retarded function with rejuvenation such as a special law accelerating urban renaissance and reorganization project. Also a fire protection performance did not satisfied the required conditions of modern FPP system, such as the function deterioration of building facilities, the technological development with FPP facilities, changed fire laws and building occupancy for social needs. Insufficiency of requirements depreciated the building value and intimidated a safety of residents. To solve this problem, the improvement of FPP was essentially required and also strongly recommended an analysis and a comparative study between the required FPP of existing building and it improving effective FPP. Therefore, purpose of this study is that establish the basic data to construct a system to analyze and compare the building FPP.

  • PDF

An Analysis of the Fire Load and Ventilation Factor in Underground Commercial Space (지하상업공간의 환기계수 및 화재하중 분석)

  • Choo Yeun-Hee;Lee Ji-Hee;Hong Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.135-142
    • /
    • 2006
  • The purpose of this study is to obtain the fire safety for underground commercial space with analysing fire loads and ventilation factors. It was adopted the investigation method of field survey with commercial uses for more confidential data. The results of this study can be summarized as follows; 1) The ventilation factor shows $0.04{\sim}0.24m^{1/2}$ and it may develop ventilation-controlled fires which have much fire hazard more than fuel-controlled fires. 2) The highest value of fire load is $158.48kg/m^2$ and appeared in footwear shop which has the value $137.35kg/m^2$ for unfixed combustibles and $21.13kg/m^2$ for fixed combustibles. 3) The average value of burning rates which mean the velocity of fire development and the fire damage range is 0.143. Therefore it is desired to decrease the combustibles of compartment and is needed the method of dispersion arrangement of goods and storage to steel cabinet and so on.

An Analytic Study on the Creep Properties for Fibers Mixed of High Strength Concrete (고강도 콘크리트의 섬유 혼입에 따른 크리프 특성 분석에 관한 연구)

  • Park, Hee-Gon;Kwon, Hae-Won;Lee, Bo-Hyeong;Bae, Yeoun-Ki;Lee, Jae-Sam;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.81-85
    • /
    • 2009
  • In the recent years, the high strength concrete has increasingly been used according to extending market of tall buildings. However, Ministry of Land, transport and Maritime Affairs was established by law with an alternative plan after June 2008 because of the weakness of high strength concrete accompanied spalling phenomena in fire. The mix design of concrete has to properly meet standards which are the spalling resistance of concrete and limited temperature of steel reinforcement. The fire proof concrete mixed fiber has widely been used to meet spalling safety on the many construction sites, the most researches about the fire proof concrete mixed fiber had being carried out focused on fire resistance, compressive strength and cast in place of concrete. But the most important thing is column shortening used the fire proof concrete within the vertical members. In this paper, the fire proof concrete filled spalling safety standards was experimented by required material when the column shortening is revised between normal concrete and fire proof concrete mixed fiber and then the results have done a comparative analysis. Also, The paper aimed to indicate a basic data for revision of column shortening of fire proof concrete.

  • PDF

A Study on the Causes of False Alarm by NFPA921 in Semiconductor Factory (반도체공장의 NFPA921에 의한 비화재보 원인조사 방안)

  • Sang-Hyuk Hong;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.87-94
    • /
    • 2023
  • This study analyzed and identified various causes of caustic alarms of 163 fire detectors that occurred from January 2019 to December 2021 at domestic semiconductor manufacturing plants equipped with about 30,000 fire detectors, and proposed a new non-fire prevention cause investigation plan by applying the NFPA 921 scientific methodology. The results of the study are as follows. First, in terms of necessary recognition and problem definition, an analog detector and an integrated monitoring system were proposed to quickly determine the location and installation space information of the fire detector. Second, in order to prevent speculative causes and errors in various analyses in terms of data analysis and hypothesis establishment, non-fire reports were classified into five by factor and defined, and the causes of occurrence by factor were classified and proposed. Finally, in terms of hypothesis verification and final hypothesis selection, a non-fire prevention improvement termination process and a final hypothesis verification sheet were proposed to prevent the cause from causing re-error.

Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature (화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동)

  • Han, Byung-Chan;Kwon, Young-Jin;Kim, Jae-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2007
  • Concrete tunnel lining must be designed to having the fireproof performance because the lining are sometimes exposed to very high temperature due to traffic accident. Such fire temperature may cause explosion of concrete, or collapse of tunnel structure. The purpose of this study is to obtain the fundamental fireproof behavior of fire resistance-engineered cementitious composites(FR-ECC) under fire temperature in order to use the fire protection material in tunnel lining system. The present study conducted the experiment to simulate fire temperature by employing 2 types of FR-ECC and investigated experimentally the explosion and cracks in heated surface of these FR-ECC. Employed temperature curve were hydro carbon(HC, ECl) criterion, which are severe in various criterion of fire temperature. The numerical analysis is carried out the nonlinear transient heat flow analysis and verified against the experimental data. The complex features of behavior in fire conditions, such as thermal expansion, plasticity, cracking or crushing, and material properties changing with temperature are considered. By the use of analytical model, the concrete tunnel subjected to fire loads were analyzed and discussed. With comparison of current concrete materials and FR-ECC, the experimental and analytical results of FR-ECC shows the better fire resistance performance than the other.

Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS (태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

Experiments on Egress of Persons with Mobile Disability in Train Car (철도차량에서의 지체장애인 피난 실험)

  • Kim, Jong-Hoon;Kim, Woon-Hyung;Roh, Sam-Kew;Lee, Duck-Hee;Jung, Woo-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.865-872
    • /
    • 2009
  • Korean railroad company is continuously improving the service for the disabled. They also install and reform many facilities for them. However, It is not considered the importance of egress when fire occurred in a cabin Now, Fire hazard analysis and risk assessment are introduced into domestic regulations for improving fire safety performance of train car and railroad facilities. Considering the fact that fire safety evaluation process doesn't fully include disabled person, fundamental egress data for them is very important for life safety aspect. In this paper, Egress experiments and analysis were conducted to measure the movement speed of the disabled with Mugunghwa and Saemaul.

The Study for Fire Prevention of Main Wooden Cultural Properties of Korea (국가지정 목조문화재의 소방대책에 관한 실태조사)

  • Back, Min-Ho;Lee, Ji-Hyang
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is searched in the on actual condition and analysis about the fire fighting measure of 123 main wooden cultural properties designated by the Cultural Heritage Administration. First, the management of wooden cultural properties and the present condition of fire occurrence are arranged. Second, The field research and the information research of related government agencies are done from August. 2008 to October. 2008 about 123 main wooden cultural properties: Cultural properties designation classification, location classification, building area, number of possession cultural properties, present condition of fire fighting, a fire engine drive direction for fire suppression, number of self-defense fire brigade, fire administrator nomination, and the distance and time from a fire station are arranged in this study. Third, the inside and outside present conditions are classified and analyzed by average index for the fire occurrence risk of 123 main wooden cultural properties. And the basic data is arranged for the fire fighting measure of main wooden cultural properties.

Analysis on the effect of the forest fire and rainfall on landslide in Gangwon area (강원지역 산사태발생지의 산불발생이력과 강우특성에 관한 분석)

  • Jun, Kyoung-Jea;Lee, Seung-Woo;Yune, Chan-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1020-1025
    • /
    • 2009
  • Recently, unusual change of weather occurred in world wide region causes localized heavy rainfall and consequently disasters like landslide and debris flow in steep slope area. And the main factors of these disasters are rainfall and forest fire. To verify the existing landslide prediction and warning system, information about landslide and rainfall were collected for a data base system and analysed.

  • PDF

Fire Characteristics of Flaming and Smoldering Combustion of Wood Combustibles Considering Thickness (목재 가연물의 두께에 따른 화염연소와 훈소상태에서의 화재특성)

  • Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.67-72
    • /
    • 2015
  • A series of fire tests was conducted to examine the fire characteristics of flaming and smoldering combustion of engineered wood products, which have been widely used for furniture and finishing materials in buildings. The engineered wood products of MDF, plywood, and chipboard were ignited by a radiant cone heater with incident heat flux of $50kW/m^2$. During the fire test, key parameters representing the fire characteristics such as the heat release rate, yield rate of combustion product, and effective heat of combustion were quantified in terms of thickness. The tests show two peak points of HRRPUA due to lateral fire propagation in the initial stage, followed by later fire penetration through the specimen thickness. The mass loss rate of flaming combustion was 5 times higher than that of smoldering combustion, while the CO yield rate of smoldering combustion was 10 times higher than that of flaming combustion. This study can contribute to the understanding of fire behavior of wood combustibles and provide useful data for fire analysis.