• Title/Summary/Keyword: Fire cases

Search Result 588, Processing Time 0.024 seconds

An Experimental Study on the Risk of Vertical Flame for a Extended-Balcony (발코니 확장에 따른 수직화염 확대 위험성에 관한 실험적 연구)

  • Shin, Yi-Chul;Youn, Yoo-Hyuk;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.283-288
    • /
    • 2008
  • Since installing a balcony can significantly reduce the spread of fire, fire spread to the upper levels was confirmed, comparing the cases with and without balcony extension. It was confirmed that the fire can spread not only to the next higher level but also to two levels higher due to the outburst of flame which reached a significant temperature in the case without balcony, while the possibility of fire spread to the upper level reduced considerably with the balcony. this study is compared and analyzed to vertical diffusion appearance of an externally venting flame. An installed balcony is also applied to fire test 6.54kW to analyze about effect of a balcony.

  • PDF

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

A Study on the Application of Gypsum Board through the Application of Fire Resistance Ceiling Structure (내화천장구조 적용을 통한 석고보드 활용 확대에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.217-218
    • /
    • 2019
  • Fire resistance ceiling system is the structure of which the ceiling installed under the slave of the structure has the fire resistance performance. Because of having the fire resistance performance, fire resistive coatings on steel beams can be reduced and large span structures can be constructed. So, it have advantages of convenience for construction, shorten for construction time and cost reducing. In foreign country, it is general that one system consisting of slave and ceiling is constructed as a fire resistance system, in these cases, gypsum boards are mostly used as ceiling materials. The purpose of this study was to explain the possibility of expanding the use of gypsum boards by securing fire resistance performance of these ceilings.

  • PDF

A Study on the Main Characteristics and Factors of the Process of Beginning Egress during the Fire at the Buildings - Focus on Overseas Fire Cases including the Japanese - (건축물 화재 시 피난개시과정의 주요 특성 및 요소에 관한 연구 - 일본 등 해외 화재사례를 중심으로 -)

  • Park, Jae-Sung
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.59-68
    • /
    • 2012
  • Predicting occupants' behaviors from the start of the fire to egress and reducing the time required for such process are critical matters that can decide success and failure of safe egress. In this research, research literatures and theories and fire cases were compared and analyzed so as to prepare logical grounds that could predict the process of beginning egress. As a result of this research, there was a significant difference in the time elapsed until people start evacuating due to spatial positions and quarantine from the place from which the fire originated and their auditive and olfactory signs did not recognize the fire instantly and they showed a strong tendency to recognize the fire by visual sign, warning announcement for egress and notice by others. And the results also showed that only a very small minority of occupants evacuated as soon as they perceived the fire and that variation in the time elapsed until evacuation begun for occupants were wider as the size of building was bigger and that accommodations such as hotel had wider variation in the time elapsed regardless of the size of buildings.

Forest Fire Ignition Patterns Caused by Farming Activities (영농활동으로 인한 산불발생 특성)

  • Koo, Kyo-Sang;Lee, Byung-Doo;Lee, Myung-Bo;Lee, Si-Young;Kim, Jeong-Hun;Park, Houng-Sek;ParK, Geon-Young
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • Farming activity was the second cause of forest fire following the carelessness. In this study, 74 forest fires caused by farming activity and waste burning in 2009 was investigated for analyzing ignition patterns. The main cause to bring about forest fire was the farming waste burning as 25 cases, burning of farming waste matter after product and household waste burning were the second causes as 19 cases. Landcovers which transfer flame from ignition point to forest were fallow field graveyard, field fruit farm, field levee fallow field. The average distance between ignition point and forest sleeve was 19 m, and the maximum distance was 130 m. The probability of forest fire ignition was high in the 100 m buffer zone from the forest sleeve that is the prohibition rule of fire use for forest fire prevention at the forest fire season.

An Analysis of Emergency Transport Proportional Population (인구비례 응급출동 현황 분석)

  • Kim, Chul-Tae
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.449-456
    • /
    • 2014
  • This study aimed to reveal the statistical correlation between the distribution of jurisdictional population and the incidence of mobilization, which consisted with cases of patient transfer and non-transfer to hospital. For this study, we collected and analysed the data for populational status, area, and cases of patient transfer and non-transfer to hospital from 5 fire stations in D city, from January 2010 to December 2012. Total numbers of mobilization were highest in J fire station and this supreme tendency were also seen in both cases (transfer and non-transfer). On the contrary, those of B fire station were lowest. In case of populational status of specific jurisdiction, S fire station was identified to possess the highest while D fire station showed the lowest. However, influences of jurisdictional population on occurrence of patient transfer and / or non-transfer to hospital were not seemed to be shown.

A Study on the Proposal of Durability and Service Life of Fire Door in apartment house (공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구)

  • Kwon, Yeong-Jin;Kim, Yun-Seong;Jin, Seung-Hyeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

Fire Identification based on Physical Properties of Bean Oil (대두유의 물리적 특성에 따른 화재감식)

  • Jin, Bog-Kwon;Jung, Soo-Il
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.246-251
    • /
    • 2008
  • Oil Fire easily generates fire in the pressure of the atmosphere and below the normal temperature. Because these discharge flammable gas and ignite within the combustibles limit in conditioning to be assisted air and an invariable density. But Kitchen Fire shows very specific properties of matter and energy Qualification in most cases even though the same oil fires occured. In this Paper, around these specific character that Kitchen Fire have Properties of matter or energy Qualification studied on the genetic mechanism and counter measure scheme.

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.