• Title/Summary/Keyword: Fire cases

Search Result 585, Processing Time 0.025 seconds

Knowledge and Current Status about AED in the Public Facilities - Focused on the Gwangju City - (다중이용시설에서의 AED에 관한 지식 및 운영실태에 관한 연구 - 광주광역시 중심으로 -)

  • Park, Si-Goo;Park, Chang-Hyun;Chae, Min-Jung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.13-28
    • /
    • 2010
  • Purpose: In this study, we investigated the better application of the law which is about the AED installation and more effective ways of emergency medical care system, to understand the law and to research the current condition of public facilities which belong to local governments, and to seize the aspect of safety guards who currently work in order to provide the installation of AED in the public facilities and to provide more efficient emergency medical service with the effectuation of the immunity law of the good intention of first-aid treatment. Methods: In Gwang-ju, 234 public facilities have been identified by 31 December, 2008. With the exception of the duplication, we researched 158 facilities and received the answers from 95 of them. Results: In the research, 53% of them have had internal emergency first-aid education, and 55% of them didn't have this education and a CPR education manual, and 30% of the facilities even didn't know how to connect with the manager of the company for the first-aid department. On the other hand, most of them were highly interested in CPR and AED education on the ratio of 91% and 93%. 88% of them have been trained about first-aid, 51% of them haven't been retrained, 17% have never been trained. so, the reality of emergency system at public facilities is serious. 78% of them knew they are working at public facilities, though 49% of them didn't know about AED installation. 57% of them didn't know the fact there is the immunity law related with good intentions for first-aid treatment. 63% of the facilities have security guards, and 30% of them didn't answer the questions. Also, many of them agreed to the opinion that all employees should have first-aid training. At representative survey report of participator of public-facility, emergency treatment is 61%, 16% of patients calling. Accordingly they importantly think better doing an on-site first-aid than evacuating the patient. And the rates show that 57% of them answerers tend to call Fire-Office(119) for evacuating the patients, and 28% of them EMIC(1339) for the first-aid. Conclusions: In this study, we are suggest to improve the details of the efficient operations and management after the grasp of the uninstallation, indifference, and unreliable conditions of AED. 1) Need a publicity of AED install cognition which is an emergency medical instrument at public facilities. 2) Arrangement of safety agents at facilities and concerns about them for good management from the parties concerned. 3) Need a designation of legal details according to the decision of the AED installation and the standard of the AED installation. 4) Training about first-aid of safety guards and the persons concerned in the facilities should be practiced participation with the positive and through this, first-aid treatment could be done by anyone who knows the immunity law related to medical emergency. 5) The brochures for the potential users and the results form practicing the instructions need to be improved in many ways through recording the emergency cases that have happened.

  • PDF

A Study on Pricing Criteria of the Laboratory Safety Inspection and Diagnosis (연구실 점검 및 진단 대가기준에 관한 연구)

  • Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.170-176
    • /
    • 2018
  • Laboratory inspection and diagnosis is a means of investigating and assessing various hazards or the state of research equipment in a laboratory, then taking appropriate safety measures to prevent accidents and injury. In many cases, laboratory inspection and diagnosis carried out by agencies are performed in a perfunctory manner that only barely satisfies the legal requirements. The aim of the present study is to provide clearly established pricing criteria for laboratory inspection and diagnosis, so as to prevent recurrence of laboratory accidents and to establish a safe laboratory environment. In order to clarify previously unclear matters, such as the lower limit for bids submitted by laboratory inspection and diagnosis agencies, technical manpower requirements, and number of laboratories inspected and diagnosed per day, a questionnaire survey was administered to agency personnel. First, when asked what the lower limit for bids submitted by agencies should be in order to improve reliability of inspection and diagnosis results and make up for the shortcomings of the lowest-bidder-wins system, 85.5% of respondents answered that the lower limit for bids should stand at no lower than 90% of the estimated price. The level of technical expertise among the technical personnel committed to laboratory inspection and diagnosis was shown to impact the reliability of results, and questionnaire results indicated a need to vary technical expertise levels depending on the degree of hazard, substances handled, and equipment used in a given laboratory. Level of technical expertise(67.1%) and number of personnel(52.6%) were shown to have a greater impact on reliability of diagnosis than on reliability of inspection. According to the results, it is determined that three persons(specialist, advanced and intermediate) should be committed to inspections, while four persons(professional, specialist, advanced and intermediate) should be committed to diagnoses. The respondents indicated a larger number of laboratories could be inspected than diagnosed per day. This can be attributed to differences in the amount of work each task involves, and the time each task takes. Assuming a six-hour work day not counting transportation, paperwork and rest, it is thought that inspection of up to 36 laboratories will be possible if each laboratory is assigned no more than 10 minutes(34.7%), while up to 24 laboratories could be inspected and diagnosed if each laboratory is assigned 15 to 20 minutes(35.1%).

A 2MC-based Framework for Sensor Data Loss Decrease in Wireless Sensor Network Failures (무선센서네트워크 장애에서 센서 데이터 손실 감소를 위한 2MC기반 프레임워크)

  • Shin, DongHyun;Kim, Changhwa
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.2
    • /
    • pp.31-40
    • /
    • 2016
  • Wireless sensor networks have been used in many applications such as marine environment, army installation, etc. The sensor data is very important, because all these applications depend on sensor data. The possibility of communication failures becomes high since the surrounding environment of a wireless sense network has an sensitive effect on its communications. In particular, communication failures in underwater communications occur more frequently because of a narrow bandwidth, slow transmission speed, noises from the surrounding environments and so on. In cases of communication failures, the sensor data can be lost in the sensor data delivery process and these kinds of sensor data losses can make critical huge physical damages on human or environments in applications such as fire surveillance systems. For this reason, although a few of studies for storing and compressing sensor data have been proposed, there are lots of difficulties in actual realization of the studies due to none-existence of the framework using network communications. In this paper, we propose a framework for reducing loss of the sensor data and analyze its performance. The our analyzed results in non-framework application show a decreasing data recovery rate, T/t, as t time passes after a network failure, where T is a time period to fill the storage with sensor data after the network failure. Moreover, all the sensor data generated after a network failure are the errors impossible to recover. But, on the other hand, the analyzed results in framework application show 100% data recovery rate with 2~6% data error rate after data recovery.

Effect of Gas- and Liquid-injection Methods on Formation of Bubble and Liquid Slug at Merging Micro T-junction (마이크로 T자형 합류지점에서 기체 및 액체의 주입 방법이 기포 및 액체 슬러그 생성에 미치는 영향)

  • Lee, Jun Kyoung;Lee, Chi Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.227-236
    • /
    • 2016
  • In the present experimental study, the effect of gas- and liquid-injected methods on the formation of bubble and liquid slug at the merging micro T-junction of a square microchannel with dimensions $600{\mu}m{\times}600{\mu}m$ was investigated. Nitrogen and water were used as test fluids. The superficial velocities of the liquid and gas were in the range of 0.05 - 1 m/s, and 0.1 - 1 m/s, respectively, where the Taylor flow was observed. The bubble length, liquid slug length, bubble velocity, and bubble generation frequency were measured by analyzing the images captured using a high-speed camera. Under similar inlet superficial velocity conditions, in the case of gas injection to the main channel at the merging T-junction (T_gas-liquid), the lengths of the bubble and liquid slug were longer, and the bubble generation frequency was lower than in the case of liquid injection to the main channel at the merging T-junction (T_liquid-gas). On the other hand, in both cases, the bubble velocity was almost the same. The previous correlation proposed using experimental data for T_liquid-gas had predicted the present experimental data of bubble length, bubble velocity, liquid slug length, and bubble generation frequency for T_gas-liquid to be ~24%, ~9%, ~39%, ~55%, respectively.

Flame Instability in Heptane Pool Fires Near Extinction (소화근처 헵탄 풀화재의 화염불안정성)

  • Jeong, Tae Hee;Lee, Eui Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1193-1199
    • /
    • 2012
  • A cup burner experiment was performed to investigate the effect of the oxidizer velocity and concentration on flame instability near extinction. Heptane was used as a fuel and air diluted by nitrogen and carbon dioxide was used in the oxidizer stream. Two types of flame instabilities at the flame base and at axial downstream were observed near extinction. The instability at the flame base could be characterized by cell, swing, and rotation modes, and the cell mode changed to the rotation mode through the swing mode as the oxidizer velocity increased. To assess the parameters for the flame instability, the initial mixture strengths, Lewis number, and adiabatic flame temperature were investigated under each condition. The Lewis number might be the most important among them, but it is impossible to generalize because of the insufficient number of cases. Furthermore, the axial periodic flickering motion disappeared at low and high oxidizer velocities near extinction. This resulted from the fact that low oxidizer velocity induced evaporated fuel velocity below the critical velocity and high velocity made the reacting fuel velocity comparable.

A Study on the Mechanical Properties of Fiber Reinforced Concrete by Kenaf Dosages (양마의 혼입량에 따른 섬유보강 콘크리트의 역학적 특성에 관한 연구)

  • Kwon, Yeong-Ho;Jun, Woo-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • The purpose of this study is to establish experimentally the mechanical properties of fiber reinforced concrete using kenaf dosages and propose the usable method of kenaf fiber in the concrete industry as natural fiber materials. Kenaf fiber help make the concrete strength including tensile and flexural stronger, more resistant to plastic and drying shrinkage, less amount of carbon dioxide because of having a rough surface and excellent tensile strength of fiber and improving the concrete's corrosion resistance. It is to select the kenaf dosages of 4 cases (0, 0.3, 0.6 and $0.9kg/m^3$ and perform various tests including slump, air content, plastic and drying shrinkage, flexural and tensile strength for fiber reinforced concrete. The results of this study are as follows : In case of increasing kenaf fiber dosages, show the slump decrease and air content increase, also take effect results for increasing concrete strength including flexural and tensile, decreasing plastic and drying shrinkage. therefore, considered test results and cost, the optimum dosages of kenaf fiber is proposed about $0.6kg/m^3$ and need to study on the site application considering concrete quality and another compared tests.

A Study on Obtaining Feedback Function of Disaster Information Management using Information & Communication Technology (ICT기술을 이용한 방재정보 관리의 환류기능 확보에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.73-88
    • /
    • 2015
  • Due to the cases of recent global warming and unusual weather etc., large-scale natural disasters such as typhoons, floods, snow damage occur frequently across the continents such as Southeast Asia and North America, South America etc. and risks of earthquakes and tsunami are also increasing gradually in Korea which has been regarded as a safe zone and disaster types are also being diversified such as typhoons, floods, heat waves, heavy snow and damage scale is also enlarged. In addition, due to geographical characteristics or lack of infrastructure, disasters tended to occur intensively around a specific region or city in the past but disasters occur throughout the country in recent years so preparation for disaster prevention has emerged as an urgent challenge issue. Therefore, considering that the plan of obtaining the effective feedback function of disaster Information is very important in the proactive and software aspects for disaster reduction, this paper analyzed this three aspects of contents, procedural and contextual aspects and proposed the plan. First, in the content aspect, building disaster prevention information communication Infrastructure, building urban and regional disaster prevention system, obtaining concurrency and sharing of information and second, in the procedural aspect, active utilization of ICT(Information and Communication Technology) of the prevention stage, disaster prevention information collection and analysis reinforcement of the preparation stage, improvement of decision-making structure and field command system of the response stage, recovery system related information promotion of the recovery stage were proposed as alternatives and finally, in the contextual aspect, if disaster prevention information is effectively managed through maintenance of disaster prevention information related systems, obtaining domainality by disaster prevention work, improvement of the ability to judge the situation, obtaining comprehensive and feedback function etc, it is considered to significantly contribute to reducing natural disasters.

A Basic Study for Securing the Business Continuity of Local Governments in the Event of Earthquake and Tsunami (지진 및 지진해일 발생 시 지방자치단체의 업무연속성 확보를 위한 기초 연구)

  • Shin, Hojoon;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.227-234
    • /
    • 2015
  • In this study, the theoretical review was carried out on the concepts regarding the continuity of operation plan and business continuity management plan, international standard ISO22301 and common required functions for disaster response, and the business continuity guideline of local governments in Japan and establishment cases were analyzed to draw matters to be reflected for establishing the business continuity plan of local governments according to the occurrence of earthquake and tsunami. In conclusion, the standard guideline of central government should be prepared for establishing the business continuity plan of local governments and the foundation to establish the plan smoothly based on such guideline should be provided. Also, the business continuity plan should be prepared based on the previous established safety management plans by reflecting the regional characteristics of local governments. And, in order to establish the business continuity plan that fits the region, proper investigations can be carried out to examine the characteristics of each organizations, resources, facilities and environments. Lastly, detailed scenario on the scale of earthquake and tsunami occurrence and damages is prepared to establish the business continuity plan of local governments and conditions for prompt countermeasures according to the scale.

A Study on the Effects of Marine Accidents by Navigation Officers' Fatigue (항해사의 피로가 해양사고에 미치는 영향 평가에 관한 연구)

  • Cho, Jun-Young;Keum, Jong-Soo;Jang, Woon-Jae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.2
    • /
    • pp.201-207
    • /
    • 2010
  • Recently, about 600 cases of marine accidents occur annually in Korea. According to many studies and analyses on occurrence of marine accidents, 70~80% of marine accidents were caused by human factors. Among the human factors, navigation officers' fatigue is very important factor. Although navigation officers' fatigue serves as an important role in marine accidents, there is no method to exactly examine the degree of officers' fatigue. Accordingly, this study analyzed human factors according to types of marine accidents and extracted important five factors affecting navigation officers' fatigue through the questionnaire survey by means of literatures and 5-point scale. In addition, evaluation factors of marine accident risks caused by fatigue factors were divided and structured by using ISM. Lastly, it found out the importance of each fatigue factor drawn by AHP and decided marine accidents that were most highly caused by navigation officers' fatigue in order. At the result, weights were high as sleep time 0.385, stress 0.302, health condition 0.139, rest time 0.099, alcohol and drug 0.074 in fatigue factors, and death and injury 0.328, collision 0.308, grounding 0.195, sinking 0.094, fire accident 0.075 in evaluation factors of marine accident risks. Therefore, the control plan to lower marine accident risks should be prepared on the basis of high weight factors.

Rearranging Emergency Medical Service Region Using GIS Network Analysis - Daejeon Metropolitan City Case Study (GIS 네트워크 분석을 활용한 응급의료서비스 권역 재조정 방안 - 대전광역시 사례 연구)

  • Kwon, Pil;Lee, Young Min;Huh, Yong;Yu, Ki Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.3
    • /
    • pp.11-21
    • /
    • 2015
  • Emergency Medical Service(EMS) has become focused due to all kinds of disaster and a great number of casualties. The 119 emergency vehicles' dispatching methods are now being focused, for travel time of ambulances are the critical components in terms of saving human lives. Therefore, this study tried to rearrange 119 EMS regions more efficiently. For this study, Daejeon Metropolitan City's real call cases were analyzed. In order to rearrange the regions, OD Cost Matrix analysis was performed between 800 thousands random points and 26 departments in the Daejoen Metropolitan City. By creating Thiessen Polygon from the random points, a new region was created. As a results, average areas of the regions were reduces from 32 square kilometers to 20 square kilometers, and average time of arrivals are were also improved. Hence, if related organizations plan to rearrange EMS regions, they may utilize this study.