• Title/Summary/Keyword: Fire analysis

Search Result 3,402, Processing Time 0.028 seconds

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

COMBUSTION TOXICITY ANALYSIS: ADVANCES USING A SPECIALIZED SAMPLING TECHNIQUE FOR FOURIER TRANSFORM INFRARED (FTIR) ANALYSIS

  • Talandis, Jonas;Innes, J.D.;Cox, A.W.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.178-184
    • /
    • 1997
  • The cone calorimeter as defined by ISO 5660, ASTM 1354, and NFPA 264A is used to assess the reaction to fire of almost any material that must be evaluated in the fire science field. Typical combustion gas analyses include oxygen, CO and CO2. Oxygen consumption is used to determine rate of heat release. Analysis of combustion gases other than oxygen, CO and CO2 has been attempted using filters to remove the solid smoke particles before analysis. This method has generated unreliable results due to the adsorption of many gas components on the active carbon . particles deposited on the filters. A technique using fourier Transform Infrared (FTIB) analysis without filtration will be disclosed and a discussion will be presented of the analytical results of toxic gases produced from various flame retarded polymeric materials. Use of such data in lethal toxic potency determinations is also reviewed.

  • PDF

Analysis on Deployment of Fire Service Force in Korea (한국 소방력배치의 실태 분석)

  • Back, Min-Ho;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.55-70
    • /
    • 2006
  • The purpose of this study is to analyze an adequate deployment of fire service force to be prepared to respond appropriately and effectively in Korea by settlement pattern. In order to examine the deployment of fire service force by the present standard, we analyzed the logical basis and the deployment of fire service force by city and province. We also classified clusters for settlement pattern through the statistical methods and raised several points for the existing deployment model of fire service force by the classified settlement pattern. As a result, it was confirmed that the deployment of fire service force by the settlement pattern was irrelevant to fire service need.

A Study on the Analytical Method for Fire Resistance Calculation of Asymmetric Slimfloor Beam (비대칭 슬림플로어 합성보의 내화성능 산정에 관한 해석적 방법 연구)

  • Park, Soo-Young;Park, Won-Sup;Kim, Heung-Youl;Hong, Gap-Pyo
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.31-37
    • /
    • 2010
  • Asymmetric Slimfloor Beam (ASB) is a composite beam developed in Europe whose asymmetric H beam is partially inserted in concrete slab. Recently in Korea, Asymmetric Slimfloor Beam has been studied in order to save the story height of a building, reduce the amount of construction materials and increase the fire resistance of a building. On this study, the fire resistance of Asymmetric Slimfloor Beam was checked by a fire test and moment capacity was calculated at fire resistance time by a heat-transfer analysis. Using the analysis result, 3-hour fire resistance constructions consisted of fireproof gypsum boards and ASB were selected and fire resistances of selected constructions were checked.

A Study on Improvement of Fire Service Deployment Standard in Korea (한국 소방력배치 기준의 개선에 관한 연구)

  • Lee, Hae-Pyeong;Back, Min-Ho
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.28-42
    • /
    • 2006
  • The purpose of this study is to offer the improvement for deployment of fire service force in Korea by settlement patterns on the basis of analysis for the present standard and deployment of fire service force. For the adequate deployment and operation of fire service force by settlement patterns, we carried out the analysis of the present standard calculated with allocation of the authorized strength. We also classified clusters for settlement pattern through the statistical methods. We proposed the standard for deployment of fire service force reflected with environmental and need factors through the introduction of standardized index.

A Study on Sensitivity Analysis for Numerical Solution of Passenger Train Fire (여객 열차 화재의 수치해석을 위한 민감도 분석)

  • Kim, Woo-Seok;Roh, Sam-Kew;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • The aim of this study is to analyse the sensitivity of fire simulation parameters including grid size and solid angle number which affect the performance of subway cabin fire simulation by FDS 4.07 version. The results of sensitivity analysis shows average of $10{\sim}20%$ differences in plume temperature, upper layer temperature, and layer height depending on the change of grid size. The study also shows that simulation with 0.05m grid size produces better resolution than that with coarse one which is 0.1m.

Study on the Reliability Analysis of Wood Floor System Exposed to Fire (화염에 노출된 목재 마루 시스템의 신뢰성 해석에 관한 연구)

  • Kim, Gwang-Chul;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.66-74
    • /
    • 2004
  • Fire performance is the important criterion for evaluating of safety of wood structures which exposed to the standard fire condition. Endurance time and time-to-failure are used as the criteria for fire performance in many countries. Reliability analysis about wood floor system which exposed to fire was carried out as preliminary research for reliability-based design on fire. Analyses were conducted by two methods, numerical analysis method and deterministic method.. They didn't show the difference between two methods. The reliability of floor exposed to fire showed strong dependence on the coefficient of variation of member and did not be influenced by the strength or load of member.

Spatial Econometrics Analysis of Fire Occurrence According to Type of Facilities (시설물 유형에 따른 화재 발생의 공간 계량 분석)

  • Seo, Min Song;Yoo, Hwan Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.129-141
    • /
    • 2019
  • In recent years, fast growing cities in Korea are showing signs of being vulnerable to more disasters as their population and facilities increase and intensify. In particular, fire is one of the most common disasters in Korea's cities, along with traffic accidents. Therefore, in this study, we analyze what type of factors affect the fire that threatens urban people. Fire data were acquired for 10 years, from 2007 to 2017, in Jinju, Korea. Spatial distribution pattern of fire occurrence in Jinju was assessed through the spatial autocorrelation analysis. First, spatial autocorrelation analysis was carried out to grasp the spatial distribution pattern of fire occurrence in Jinju city. In addition, correlation and multiple regression analysis were used to confirm spatial dependency and abnormality among factors. Based on this, OLS (Ordinary Least Square) regression analysis was performed using space weighting considering fire location and spatial location of each facility. As a result, First, LISA (Local Indicator of Spatial Association) analysis of the occurrence of fire in Jinju shows that the most central commercial area are fire department, industrial area, and residential area. Second, the OLS regression model was analyzed by applying spatial weighting, focusing on the most derived factors of multiple regression analysis, by integrating population and social variables and physical variables. As a result, the second kind of neighborhood living facility showed the highest correlation with the fire occurrence, followed by the following in the order of single house, sales facility, first type of neighborhood living facility, and number of households. The results of this study are expected to be useful for analyzing the fire occurrence factors of each facility in urban areas and establishing fire safety measures.

A Study on the Analysis, and Improvement of Fire Investigation Related to Product Liability Law (제조물 책임법에 따른 화재조사의 실태분석 및 개선방안에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.112-119
    • /
    • 2010
  • In this research paper, the analysis, and improvement, of conditions of fire investigation related to products were derived. The results of the research showed that the main entity that plays the role of coordinator on the scene of fire investigation is unclear, systematic devices to protect the rights and interests of fire victims are inadequate, there are limitations in deriving the cause of fire due to the lack of fire appraisal organizations in fire departments, and the product companies are passive in their initial actions. As for improvement measures, it was found that the adoption of the system in which fire departments can play the role of mediator on the scene of fire investigation, the establishment and operation of fire appraisal organizations and research institutes in fire departments, and the establishment of network between fire departments and product companies are needed.

Analysis of the Causes of Multiple Casualties in an Electronics Factory Fire (전자공장 화재의 다수 사상자 발생원인 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.130-139
    • /
    • 2019
  • The electronics factory fire, that occurred at 15:40 on August 21, 2018, killed nine people and injured six. This study analyzes the causes of many of the casualties from the fire, and is based on fire investigation results and so on. The findings suggest that major causes included failure of the automatic alarm system to function, failure of the emergency broadcasting system to function, the fire suddenly spreading due to polyurethane foam in a ceiling on the 4thfloor, a power outage immediately after the fire started, a sprinkler system that was not working, a delay in reporting the fire, and improper management of fire facilities by a fire safety management company.