• Title/Summary/Keyword: Fire Shutters

Search Result 16, Processing Time 0.019 seconds

A Fire Computer Simulation of Inner Space with Fire Shutters and Refuge Stairs (방화셔터와 피난계단이 존재하는 실내 환경의 화재 컴퓨터 시뮬레이션)

  • Yoo, Doo-Yul;Yang, Jung-Min
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1617-1624
    • /
    • 2013
  • This paper analyzes the relation between fire shutters and fire spread by conducting fire simulation on inner space with fire shutters. Using Fire Dynamics Simulator (FDS), a commercial fire simulation software, the simulation is done on an ideal inner robby, where fire size and the open/close of fire shutters are varied. Our simulation environment can derive significant fire parameters such as temperature variation of fire room walls and entrances of refuge stairs, variation of carbon dioxide, and soot spread. According to the simulation results, temperature and carbon dioxide distribution in refuge stairs have little dependence on vent open or close, but the part close of fire shutters blocks soot inflow to refuge stairs.

Analysis of the Working Conditions of Screen Fire Shutters in the Goyang Bus Terminal Fire (고양종합터미널화재 시 스크린방화셔터의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.82-91
    • /
    • 2018
  • This study analyzed the working conditions and problems of screen fire shutters in the Goyang Bus Terminal fire based on the fire investigation results. At that time, screen fire shutters in the 1st basement, which was under construction, did not work because the power was shut off. Four screen fire shutters in the 1st and 3rd floor did not work despite the power not being shut off. The following problems related to a screen fire shutter were found: shutting off the power to screen fire shutters for the fire compartment on each floor, even when the fire compartments were changed in each area; installing an integral type screen fire shutter without any regulations, installing a two-stage screen fire shutter in a place not related to obstacles during evacuation; stopping the function of the screen fire shutters for a fire compartment on each floor after a combustible sandwich panel was comparted; installing a screen fire shutter over 10 meters in width, in which its performance was not verified; and no safety control standards for reinstalling or maintaining a screen fire shutter.

A Study on the Analysis of Operation Reliability of Fire Doors and Fire Shutters Using Fire Statistical Data (화재통계자료를 활용한 방화문, 방화셔터 작동신뢰성 분석에 관한 연구)

  • Jin, Seung-hyeon;Kim, Hye-Won;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.119-120
    • /
    • 2020
  • In order to establish an evaluation method that can quantitatively evaluate the fire safety of existing buildings in Korea, a stochastic approach is needed to consider the extent of damage in the event of actual fire, along with the operation and installation of facilities. Accordingly, as a basic study for the establishment of fire safety assessment methods for buildings, this study aims to analyze the results of safety inspection and the degree of damage caused by the operation of fire doors and fire shutters in order to derive the reliability of fire doors and fire shutters. As a result, the results of inspection of fire shutters and fire doors and the results of operation using fire statisticians are as follows. As a result of the inspection, the positive rate of fire doors was about 82% and 98% of normal operation was derived from the fire investigation.

  • PDF

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

A Numerical Study on the Smoke Control in Center-Platform Type Subway Station Fires (섬식 지하철역사내 화재시 연기제어에 관한 수치해석적 연구)

  • Lee, Sung-Ryong;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.313-318
    • /
    • 2007
  • In this study, numerical simulations were carried out to analyze the effect of the smoke extraction system and fire shutters in subway station fires using FDS 4.0. Subway station used in the experiment was 145 m long. Simulation results are validated by comparing with experimental results. Simulation results showed good agreement with experimental results within $10^{\circ}C$. 10 MW polystyrene was used as a fuel in the numerical prediction. Numerical predictions were performed in the center-platform type subway station in case of a kiosk fire. Temperature and CO concentration were lowered by the operation of smoke extraction system. But, the operation of fire shutters had little effect on temperature and CO concentration in the platform level.

Suggestion of a Check List to Prevent Fall Incidents Through Case Analysis of Electric Shutters in Buildings (건축물 전동셔터 사례 분석을 통한 추락방지 체크리스트 제안)

  • Jung, Young-Min;Bang, Hong-Soon;Kim, Ok-Kyue
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.3
    • /
    • pp.259-268
    • /
    • 2022
  • Electric shutters for buildings are being developed in Korea and abroad on a regular basis and can be used in different types of buildings such as company buildings and fire stations, etc. However, the fall risk factors induced by a variety of functions of building electric shutters require safety control. We reviewed the technological trends and legal standards in Korea and abroad, analyzed incident cases, and identified fall risk factors requiring control. We inspected all the building electric shutters in Korea based on the fall risk factors. As a result, we identified 91 noncompliance cases, in 69 percent of all 132 locations. In this study, backed by the inspection results, we suggest a check list to prevent the fall of building electric shutters to ensure safety and conduct verification using a focus group interview.

A Study on the Effects of All-in-one Automatic Fire Shutters Installed in High School on Evacuation Time

  • Lee, Soon Beom;Kong, Ha Sung;Lee, Jai Young
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.182-192
    • /
    • 2022
  • This study analyzed the effects of the all-in-one automatic fire shutter (hereinafter referred to as "all-in-one shutter") installed along the fire compartment in a five-story high school building on the evacuation time by using the Pathfinder simulation program. When the all-in-one shutter was added as a new variable, the evacuation time was delayed, indicating insufficient evacuation safety. The evacuation time exceeded the appropriate standard when the evacuation exit was designated to the students in the present state of being placed on the 2nd, 3rd, and 4th floors and the all-in-one shutter was activated. When students were placed on the 1st, 2nd and 3rd floors under the same conditions, the evacuation time was also greatly exceeded. However, when the width of the entrance was set to 130cm, the evacuation time was almost the same as when the all-in-one shutter was not installed. In high-rise school buildings, the bottleneck caused by all-in-one shutters is becoming a major factor in evacuation barriers. To ensure the evacuation safety of school buildings, it has been judged that evacuation education and training to predict the evacuation time required through the all-in-one shutter entrance and induce an evacuation procedure suitable for the standard evacuation time should be carried out in parallel. The implications of this study and suggestions for effective fire compartments and follow-up studies were discussed.

A Study on the Hazard of Radiant Heat of the Fire Shutters in Fire (방화셔터 복사열의 위험성 예측에 관한 연구)

  • Jeon, Jun-Pyo;Min, Byung-Yeol;Jeon, Soo-Min;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.160-164
    • /
    • 2011
  • 국내 건축법에서는 화재의 확산을 방지하기 위해 방화구획을 설치하여 인명피해와 재산피해를 최소화 하고 있다. 따라서 방화구획 개구부의 방화문, 방화셔터 등 각종 배관 관통부 시스템의 화재저항 성능이 중요하다. 이에 본 연구에서는 방화구획 중 넓은 면적에 사용되는 방화셔터를 각 종류별 내화성능실험을 통하여 방화셔터의 방화성능 확인과 더불어 실험시 방화셔터에서 발생하는 복사열의 측정을 통하여 화재가 확대될 수 있는 위험성을 예측하였다.

  • PDF

A Numerical Study on the Smoke Control in Side-Platform Type Subway Station Fires (상대식 지하철 역사내 화재시 연기제어에 관한 수치해석적 연구)

  • Lee, Sung-Ryong;Ryou, Hong-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.81-86
    • /
    • 2008
  • In this study, numerical simulations were carried out to analyze the effect of the smoke extraction system and fire shutters in subway station fires using FDS 4.0. Subway station used in the experiment was 205 m long. Simulation results are validated by comparing with experimental results. Simulation results showed good agreement with experimental results within $20\;^{\circ}C$. 20 MW polystyrene was used as a fuel in the numerical prediction. Numerical predictions were performed in the side-platform type subway station in case of a train fire. Temperature and CO concentration were lowered by the operation of smoke extraction system.