• Title/Summary/Keyword: Fire Sensor

Search Result 423, Processing Time 0.033 seconds

A Design of Fire Monitoring System Based On Unmaned Helicopter and Sensor Network (무인헬기 및 센서네트워크 기반 화재 감시 시스템 설계)

  • Yun, Dong-Yol;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 2007
  • Recently, fires happen to occur owing to various factors. However, the demage caused by the fire is eyer increasing because timely actions could not be taken. To reduce the demage, a development of fire detection system which makes it possible to take adequate actions is requited. In this work, a sensor network-based fire detection system which utilizes both sensor nodes equipped with smoke sensor and unmaned helicopter is proposed. The proposed system is composed of unmaned helicopter which can gather the measurement data from the deployed sensor nodes and the embedded system which can get visual information on the firing spot and transmit these images to a remote server computer. The proposed system is applied to actual test bed to verify its feasibility.

A Study of Robotic Risk Confrontation Administration on the Ship Fire (선박 화재시의 Robot을 이용한 Risk 대응 관리 연구)

  • Park, Dea-Woo;Park, Young-suk;Nam, Jae-Min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.276-279
    • /
    • 2009
  • Is introducing ship automation system for the safety of ship and work environment mend recently. Is endeavoring for sea safety and fire at sea prevention solidifying control of standard technology and safety supervision aspect in IMO but sea accident and ship fire are happening continuously. Because using Robot in artistic talent of ship in this treatise, studied that correspond to Risk and manage. Attach fire perception sensor for Robot's Risk confrontation, and because using infrared rays sensor, TOUCH SWITCH, sound perception sensor, gas perception sensor, light perception sensor that is threaded in Robot and is achieved, controlled Robot, and establish Low-High value the speed of sound output use and DC MOTOR and COM SEN of when indicate Risk confrontation to Robot and establish Robot's Risk confrontation administration action.

  • PDF

Design of Integrated Smart Fire Protection System for Rack Storage (랙크식 창고 통합 스마트 화재대응 시스템 설계)

  • Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.26-36
    • /
    • 2020
  • It is very difficult to suppress fire by rapid flame spread through flue space between flammable commodities on the rack when a fire occurs in the rack storage. At present, the fire protection system for rack storage in Korea has many issues, and the new fire protection system was designed and developed by it. A smart system using the sensor network and artificial intelligence was designed to detect fire very rapidly and track the location of a fire. In the very early stages, the system was constructed using vertical open sprinkler pipes, wet pipes, and solenoid valves to allow water to spray near fire locations. Based on the design results, the system was installed and tested, and the full-scale test was successfully completed.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.

  • PDF

A Study on Integrated Fire Alarm System for Safe Urban Transit (안전한 도시철도를 위한 통합 화재 경보 시스템 구축의 연구)

  • Chang, Il-Sik;Ahn, Tae-Ki;Jeon, Ji-Hye;Cho, Byung-Mok;Park, Goo-Man
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.768-773
    • /
    • 2011
  • Today's urban transit system is regarded as the important public transportation service which saves passengers' time and provides the safety. Many researches focus on the rapid and protective responses that minimize the losses when dangerous situation occurs. In this paper we proposed the early fire detection and corresponding rapid response method in urban transit system by combining automatic fire detection for video input and the sensor system. The fire detection method consists of two parts, spark detection and smoke detection. At the spark detection, the RGB color of input video is converted into HSV color and the frame difference is obtained in temporal direction. The region with high R values is considered as fire region candidate and stepwise fire detection rule is applied to calculate its size. At the smoke detection stage, we used the smoke sensor network to secure the credibility of spark detection. The proposed system can be implemented at low prices. In the future work, we would improve the detection algorithm and the accuracy of sensor location in the network.

  • PDF

Early Fire Detection System for Embedded Platforms: Deep Learning Approach to Minimize False Alarms (임베디드 플랫폼을 위한 화재 조기 감지 시스템: 오경보 최소화를 위한 딥러닝 접근 방식)

  • Seong-Jun Ro;Kwangjae Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.298-304
    • /
    • 2024
  • In Korea, fires are the second most common type of disaster, causing large-scale damages. The installation of fire detectors is legislated to prevent fires and minimize damage. Conventional fire detectors have limitations in initial suppression of failures because they detect fires when large amounts of smoke and heat are generated. Additionally, frequent malfunctions in fire detectors may cause users to turn them off. To address these issues, recent studies focus on accurately detecting even small-scale fires using multi-sensor and deep-learning technologies. They also aim at quick fire detection and thermal decomposition using gas. However, these studies are not practical because they overlook the heavy computations involved. Therefore, we propose a fast and accurate fire detection system based on multi-sensor and deep-learning technologies. In addition, we propose a computation-reduction method for selecting sensors suitable for detection using the Pearson correlation coefficient. Specifically, we use a moving average to handle outliers and two-stage labeling to reduce false detections during preprocessing. Subsequently, a deep-learning model is selected as LSTM for analyzing the temporal sequence. Then, we analyze the data using a correlation analysis. Consequently, the model using a small data group with low correlation achieves an accuracy of 99.88% and a false detection rate of 0.12%.

Implementation of Multiple Sensor Data Fusion Algorithm for Fire Detection System

  • Park, Jung Kyu;Nam, Kihun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.7
    • /
    • pp.9-16
    • /
    • 2020
  • In this paper, we propose a prototype design and implementation of a fire detection algorithm using multiple sensors. The proposed topic detection system determines fire by applying rules based on data from multiple sensors. The fire takes about 3 to 5 minutes, which is the optimal time for fire detection. This means that timely identification of potential fires is important for fire management. However, current fire detection devices are very vulnerable to false alarms because they rely on a single sensor to detect smoke or heat. Recently, with the development of IoT technology, it is possible to integrate multiple sensors into a fire detector. In addition, the fire detector has been developed with a smart technology that can communicate with other objects and perform programmed tasks. The prototype was produced with a success rate of 90% and a false alarm rate of 10% based on 10 actual experiments.

Design and Implementation of a Real-time Automatic Disaster and Information Broadcasting System (시뮬레이션 프로그램 기반 실시간 자동재난 및 안내방송시스템의 설계)

  • Lee, Byung-Mun;Park, Jung-In;Kang, Un-Gu
    • Journal of Digital Convergence
    • /
    • v.10 no.7
    • /
    • pp.141-152
    • /
    • 2012
  • The typical evacuation guidance system based on fire detectors, which is being widely used in theaters and large buildings, is often operated in an analog manner. In case of fire, it often causes the system to lose a wired line or wireless fire detection sensor, resulting in the difficulty of transmitting signals from a wired or wireless fire detection sensor to the main fire monitoring device. Accordingly, this paper has proposed the broadcasting system for disaster management, having an efficient evacuation guidance plan when a disaster occurs. The system reacts to an emergency situation along with fire alarm sirens in real time. We have implemented the above system by means of a simulation program that prints the evacuation guidance information (e.g., location and time of fire, and evacuation path) on an LCD located in a building through the fire sensor network in case of an emergency (e.g., actual fire). We have developed the simulation system by using mathematical algorithms, such as the optimal path search and the fire smoke diffusion algorithm. This simulation program considers the structure of a building and the location where the fire has initially occurred, applying it to the simulator.

The devepoement of a raid and fire preventable system using the Zigbee communication and multi-sensor (ZigBee 통신 및 다중센서를 이용한 방범.방재 시스템 개발)

  • Han, Young-Oh
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.5
    • /
    • pp.193-200
    • /
    • 2009
  • In this paper, the raid and fire preventable system using Zibee module with IEEE 802.15.4 wireless communication standard and multi-sensor was developed displaying raid and firing condition with wireless network. The raid preventable system is designed using a ultrasonhe waves sensor and infrared sensor. The fire preventable system is designed using a thermistor. The datas for raid and firing condition are communicated from enddevice to coordinator with wireless network and are displayed on PC monitor.

  • PDF