• Title/Summary/Keyword: Fire Safety Test

Search Result 543, Processing Time 0.024 seconds

A Development and Performance Experiment on In-rack Sprinkler Head for Rack Type Warehouse (적층식 대형창고 스프링클러헤드 개발 및 성능실험)

  • Kim, Woon-Hyung;Lee, Jun;Hong, Seong-Ho;Kim, Jong-Hoon;Yang, So-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.214-222
    • /
    • 2019
  • Purpose: The purpose of this study is to develop a sprinkler head that can be controlled and initial suppressed by installing it in a rack-type warehouse. Method: Considering the spray radius and spray pattern, various deflectors were designed, and the spray angle, discharge characteristics and protection performance test was conducted, and these results were compared and analyzed. Results: An optimal sprinkler head was developed to protect full load, front side of a commodity with minimum water volume 115L/min. Conclusion: The developed head of K-115 and 1Bar pressure was tested with one tier storage confirming that the fire control is carried out without burning all the loadings. In addition, the vertical distance from the top of the load to the deflector shall be separated by 450mm and installed to allow sufficient discharge to the outer part of the commodity.

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

Estimation of Strength Parameter of Soil-NSS Mixture by Triaxial Compression Test (삼축압축시험을 이용한 NSS 혼합토의 강도정수 평가)

  • Oh, Sewook;Lee, Gilho;Kwon, Hyekkee;Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.65-71
    • /
    • 2013
  • Despite of the various merits of soil pavement, it has not been widely adapted because portland cement was conventionally used as soil stabilizer to improve the mechanical properties such strength parameters. Recently, natural soil stabilizer(NSS) were developed and virtually adopted to several case of soil pavement construction under control of heavy metal pollution compared to cement-used cases. However, the application of natural soil stabilizer is not settled yet, and empirical design have been widely adopted. In this study, therefore, the strength parameter of soil-NSS mixture was estimated by some triaxial compression tests, CU-test. From the tests, the relationship between curing period and strength parameter such as internal friction and effective cohesion was examined. As a result, effective cohesion of dredged clay and granite soil increased as curing time is increased. However, internal friction is almost same result in all soil type used in this study.

Child-Care Facility and Kindergarten's Demands on Foodservice Support by Center for Child-Care Foodservice Management (CCFSM) in Seoul and Gyeonggi-do (서울.경기지역 보육시설 및 유치원 대상 어린이급식관리지원센터 지원 요구도 분석)

  • Kim, Soo-Youn;Yang, Il-Sun;Yi, Bo-Sook;Baek, Seung-Hee;Shin, Seo-Young;Lee, Hae-Young;Park, Moon-Kyung;Kim, Young-Shin
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.6
    • /
    • pp.730-739
    • /
    • 2011
  • The purpose of this study was to analyze the differences between child-care facilities and kindergartens towards the need for foodservice support by Center for Child-Care Foodservice Management (CCFSM). For this study, questionnaires were sent out from August of 2008 to April of 2009 to directors of 1,478 child care facilities and 299 kindergartens in Seoul and Gyeonggi-do via postal service. A total of 267 questionnaires were usable with 203 (13.7%) of child-care facilities and 64 (21.4%) of kindergartens. Statistical data were analyzed by SPSS 15.0 for descriptive analysis and t-test. For political and administrative support, government funding for foodservice was the highest need and hiring nutritionists was significantly different by type of facility (p < 0.01). Both child-care facilities (4.29) and kindergartens (4.41) demanded the balanced menu from CCFSM. There were significant differences of "information about food material sanitation management" (p < 0.05), "hygiene safety management method according to working process" (p < 0.05), "hygiene safety management method of foodservice facilities and equipment" (p < 0.05). In education and training contents from center, "types and methods to manage foodservice facilities and equipment" for directors, "dietary education by age" for teachers, and "the rules of personal sanitation and working process" and "gas, electricity and fire prevention" for culinary workers had the highest mean score of requirements.

Development of Tunnel-Environment Monitoring System and Its Installation III -Measurement in Solan Tunnel- (터널 환경 측정 시스템 개발 및 측정 III -솔안터널 측정결과 분석-)

  • Park, Won-Hee;Cho, Youngmin;Kwon, Tae-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.637-644
    • /
    • 2016
  • This paper is a follow-up to previous papers entitled, "Development of Tunnel-Environment Monitoring System and Its Installation" I [1] and II [2]. The target tunnel of these studies is the Solan Tunnel, which is a loop-type, single-track, 16.7-km-long tunnel located in mountainous terrain and passing through the Baekdudaegan mountain range. It is an ordinary railway tunnel designed for both freight and passenger trains. We analyzed the environmental conditions of the tunnel using temperature and humidity data recorded over approximately one year. The data were recorded using the Tunnel Rough Environment Measuring System (TREMS), which measures environmental data in subway and high-speed train tunnels and is installed in three locations inside the tunnel. Previous studies analyzed environmental conditions inside tunnels located in or near a city, whereas the tunnel in this study is located in a mountainous area. The tunnel conditions were compared with those measured outside the tunnel for each month. Hourly changes during summer and winter periods were also analyzed, and the environmental conditions at different locations inside the tunnel were compared. The results are widely applicable in studies on the thermal environment and air quality of tunnels, as well as for computer analysis of tunnel airflow such as tunnel ventilation and fire simulations.

Design and Experimental Verification of Uni-Injector Using Gas Methane and Lox as Propellants (가스메탄/액체산소를 추진제로 하는 단일 인젝터 설계 및 실험적 검증)

  • Jeon, Jun Su;Min, Ji Hong;Jang, Ji Hun;Ko, Young Sung;Kim, Sun Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.275-283
    • /
    • 2013
  • An injector that uses methane gas ($CH_4$) and liquid oxygen ($LO_x$) as propellants was designed to verify the combustion characteristics of an engine that uses methane, which is one of the next-generation propellants. A swirl/shear coaxial-type injector was used, and flow analysis was performed using Fluent to determine the main design parameters of the injector. A hydraulic test was performed to understand the atomization and spray pattern characteristics of the injector. Next, a combustion test was performed at the design point to understand the ignition and combustion stability. Additional combustion tests were performed according to the O/F ratio to investigate the combustion characteristics and stabilities using the characteristic exhaust velocity ($C^*$) and fluctuation of the chamber pressure. The experimental results showed that the combustion efficiency was greater than 90%, and the pressure fluctuation was lower than 2% under all conditions.

Mechanical Characteristics of Ultra High Strength Concrete with Steel Fiber Under Uniaxial Compressive Stress (강섬유로 보강된 초고강도 콘크리트의 일축압축 상태에서의 기계적 특성)

  • Choi, Hyun-Ki;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.521-530
    • /
    • 2015
  • Design of fiber reinforced ultra-high strength concrete members should be verified with analytical or experimental methods for safety. Members with compressive strength larger than limitation of current design code usually be designed with analytical verification using stress-strain relation of concrete and reinforcements. For this purpose, mechanical characteristics of steel fiber reinforced ultra-high strength concrete were defined under uniaxial compression. Mix proportions of test specimens were based on reactive powder concrete and straight steel fibers were mixed with different volume fraction. Compressive strength of matrix were distributed from 80 MPa to 200 MPa. Effect of fiber inclusion were investigated : increase of compressive strength of concrete, elastic modulus and strain corresponding to peak stress. For the wide range application of investigation, previously tested test specimens were collected and used for investigation and estimation equation. Based on the investigation and evaluation of previous research results and estimation equation of mechanical characteristics of concrete, regression equations were suggested.

Job Satisfaction and Work Stress of EMT-paramedic's According to type of Occupation (1급 응급구조사의 직종에 따른 직무만족도 및 업무스트레스)

  • Kim, Duk-Won;Cho, Seong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.584-593
    • /
    • 2017
  • This study provides basic data needed to improve the working environment of the first class emergency medical technicians, in order to decrease their job stress and increase their job satisfaction. Job stress and satisfaction were compared and analysed in emergency medical technicians who were working for 119 rescue and hospitals at the time when twenty-one years had passed after the initial training of emergency medical technicians in order to identify differences between 119 rescue and hospitals, and their advantages and disadvantages. The subjects of the study were 182 first-class emergency medical technicians who were working in twenty-eight 119 rescue centers and fourteen national and local emergency medical centers in Gwangju, Jeollanamdo and Jeollabukdo. The study subjects were interviewed by questionnaire. For statistical analysis, SPSS/WIN 20.0 was used, and the results were analysed with chi-square, t-test, ANOVA, and ANCOVA testing. There was no significant difference in job stress between the subjects working in 119 rescue centers (2.92) and those working in hospitals(3.01). The satisfaction score of fire-fighting workers was 2.98 and that of hospital workers was 2.54. Hospital workers' satisfaction was significantly lower (p<0.001). The score of hospital workers' pay satisfaction was the lowest($2.07{\pm}0.62$). The job stress decreased and job satisfaction increased with decreasing monthly average number of patients(p<0.001), increasing monthly income(p=0.047), and more frequent holidays they had(p<0.001), the less. For less job stress and higher job satisfaction, welfare conditions both at 119 rescue and hospitals should be improved. 119 rescue centers should develop violence prevention measures and offer resting places for emergency medical technicians. Hospitals should pay more attention to the yearly pay increase rate and stability in employment types.

Oral Hygiene Knowledge and the Actual Condition of Oral Care for the Students in the Public Health and non-Public Health Departments (보건계열학과와 비보건계열학과 학생들의 구강위생지식 및 관리 실태)

  • Lee, Jong-Do;Shin, Du-Man;Park, Jong-Tack
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.447-455
    • /
    • 2012
  • Purpose: This study was to investigate oral hygiene knowledge and the actual condition of oral care for the students in the public health and non-public health Departments. Methods: The survey sample consisted of 262 randomly selected students. 197 of them are public health-related students and 65 are non-public health-related students. The questionnaires used in this study consisted of 4 items for general information, oral health status of 2 items, 5 items for Oral hygiene knowledge and actual condition of oral care of 5 items. Collected data were analyzed by Frequency Analysis t-test and Crosstabs using SPSS(Statistical Package for Social Sciences) Win 19.0 statistics program. Results: Regarding general characteristics of the subjects, there were 53.8% of first-year student, 26.0% of second-year student and 20.2% of third-year student among 52.3% of males and 47.7% of females. The subjects received less than "100,000" won(13.0%), "100,000-190,000" won (5.0%), "200,000-290,000" won(30.9%), "300,000-390,000" won (33.2%) and more than "400,000" won(17.9%) a month for an allowance. The subjects had 'none' (44.3%), '1'(6.5%), '2'(12.6%), '3'(5.0%), '4'(5.3%), 'more than' 5(0.8%) of dental caries and 'do not know' were 25.6%. The numbers of dental prosthetics were 'no' (35.5%), '1'(13.7%), '2'(17.2%), '3'(10.3%), '4'(11.5%), and 'more than 5'(11.8%). The public health students(84.8%) had a higher positive response rate than the non-public health students(66.2%). The public health students(80.2%) had a higher negative response rate than the non-public health students(78.5%) in the result of onset of gum disease pain awareness. The non-public health students(65.5%) had a higher negative response rate than the public health students(68.3%)) in the result of heredity of gum disease. The t-test showed that public health-related department students(M=8.264, SD=0.821) had more knowledge about oral hygiene than non-public health-related department students(M=8.015, SD=1.082). 'do not use' in the oral care products except toothpaste and toothbrush showed that public health-related department students(60.4%) use the products more than non-public health-related department students(66.2%). Conclusion: In this study, public health-related department students had higher oral hygiene knowledge and actual condition of oral care compared to non-public health-related students, but low in practical action. Due to the lower level of dental care products use in non-public health-related department, a continuous oral care education program is required.

Evaluation of Field Application and Optimum Operational Condition for Heavy Metals Analysis Using Environment-Friendly Bismuth Film Electrode (친환경 비스무스 필름 전극을 이용한 중금속 분석 최적조건 도출 및 현장 적용성 평가)

  • Kim, So-Youn;Yang, Yong-Woon;Jeon, Sook-Lye
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.137-142
    • /
    • 2011
  • This study was conducted to establish the optimal electrolyte and bismuth concentrations using bismuth film electrode in laboratory and to confirm the possibilities of using this operational condition for heavy metals monitoring in field. In lab test, heavy metal measurement was not accurate more than 600 ppb when heavy metal (Pb, Cd, Zn) range 100~1,000 ppb was measured with bismuth 2,000 ppb. So, bismuth and heavy metal was reacted about 1:1 with ASV method. In electrolyte test, 0.1 M acetate buffer (pH 4.5), 0.1 M chloroacetate buffer (pH 2.0), 0.1 M HCl (pH 2.0), 0.1 M $HNO_3$ (pH 2.0) was tested. As a results, 0.1 M acetate buffer was most suitable in ASV measurement with bismuth film electrode. In field application, Pb, Cd and Zn was measured respectively 36~45 ppb, 84~91 ppb, 90~98 ppb when heavy metal (Pb, Cd, Zn) 100 ppb was spiked in field sample. These results were identified of matrix effect in field sample, So relationship between heavy metal measurement and matrix effects will be studied.