• Title/Summary/Keyword: Fire Safety Indicator

Search Result 18, Processing Time 0.022 seconds

Fire Safety Consciousness Indicators Development and National Fire Safety Consciousness Research (소방안전의식 지표개발 및 국민 소방안전의식 조사 연구)

  • Jeong, Mu Heon;Park, In-sun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.89-94
    • /
    • 2015
  • The purpose of this study is to investigate national fire safety consciousness (FSC). A FSC survey would help with proper fire safety policy. Indicators to define and measure efficiently the FSC were broken down into five areas: prevention, alarm, evacuation, extinguishing, and damage expansion prevention. The indicators were developed using Parasuraman's method based on domestic and foreign research materials and meetings with experts. FSC was surveyed using the indicators on Gallup Korea. The results of the survey analysis show that evacuation is lowest, followed by extinguishing, alarm, prevention, and damage expansion prevention.

Analysis of Current Signals for Overcurrent and Series Arc in Traditional Market Shops (재래시장 상가에서 과전류 및 직렬아크의 전류 신호에 대한 분석)

  • Kim, Doo-Hyun;Hwang, Dong-Kyu;Kim, Sung-Chul;Kim, Sang-Ryull;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.42-48
    • /
    • 2012
  • This paper is aimed to analysis of electrical fire risk by overcurrent and series arc signals in traditional market shops Firstly, the field state investigation was conducted for shops at the traditional market (30 shops). At each shop in the traditional market, load characteristics were investigated and thermal characteristics in Panel were analyzed. Thermal characteristics in Panel is an indicator that can determine the impact of overcurrent. Results of the field state investigation found out four shops which showed abnormal thermal characteristics in Panel. Electrical load characteristics of these 4 shops were simulated by experimental setup consists of generator, motor and heater. In order to verify the electrical fire risk by electrical loads of 4 shops, arc and overcurrent experiments were conducted. The waveshapes of arc and overcurrent are investigated in both the time and frequency domains to find signal characteristics. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the shops in the traditional market.

Analysis on Emergency Power Supplies in Buildings and a Model for Safe Operation of the Emergency Power System (건축물의 비상전원 적용실태 및 자가발전설비의 안전 운전 모델에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2012
  • The purpose of this paper is to present a model for operating an emergency power system(EPS) that can secure a sufficient power supply used in case of a fire by analyzing the status of power supplies for emergency and firefighting operations. Investigations on the one of the causes of the operational failure of firefighting systems show evidence of EPS. Generally, when power to a building is interrupted, EPS supplies the emergency load(excepted firefighting load) first. When a power outage and a fire occur simultaneously, the EPS must be able to supply both the emergency load and the firefighting load, especially the firefighting load to the end. However, in order to save construction costs, emergency power generators in apartment, commercial, and business buildings can satisfy only one of the required loads. In cases like this, when a power outage and a fire occur simultaneously, there is a danger of firefighting equipment not operating due to insufficient power supply from the emergency generator. Therefore, an EPS must have a reserved firefighting power that can supply both the firefighting and the emergency load. Such EPS, when faced with a danger of an overload, will shut down the supply to all or part of the emergency load, thus securing a continuous power supply to the firefighting equipment. The generator power system with reserved firefighting power (RFP) will also have an indicator to show that the selective control is being used. General power generation systems for emergency load and firefighting load were found to have a demand factor of 50-60% with a lump. However, when installing an EPS, the builders must choose the higher demand factor suggested according to the official approval demand factor of the building.

A Conceptual Study of a Framework for Real-Time Railway Safety Monitoring and Control System Based on Safety Performance Monitoring Indicators (안전성과 모니터링지표 기반의 실시간 철도안전 감시제어 시스템의 프레임워크에 대한 개념 연구)

  • Lee, Donghoun;Tak, Sehyun;Kim, Sangahm;Yeo, Hwasoo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.526-538
    • /
    • 2016
  • The government of South Korea has made great efforts in the area of railway safety management by means of a railway safety law and an integrated railway safety plan established in 2004 after the Daegu subway fire accident. However, after certain railway incidents, a reactive railway safety management system has been implemented that has led to fatal accidents caused by the collision, derailment, and fire every year. Hence, this study is intended to propose a framework that integrates data from distributed detection devices into a real-time railway safety monitoring and control system for proactive safety management. Furthermore, we will provide a future development direction for safety performance monitoring indicators to determine whether the railway safety monitoring and control system works effectively. The proposed framework is expected to be a cornerstone for the real-time railway safety monitoring and control system to be implemented in the future.

Experimental Performance Evaluation of a Fire System for Apartment Buildings (공동주택 전용화재시스템의 성능평가를 위한 실험적 연구)

  • Jung, Jong-Jin;Hong, A-Reum;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.51-56
    • /
    • 2015
  • In Korea, measures to maintain sustainable fire safety performance for apartment buildings are insufficient in terms of fire-fighting products, skilled personnel, and maintenance status. Also, because of the particular features of a fire compartment, it has structural problems that are very likely to cause damage to human life when a fire occurs. Currently, problems with the fire supervisory system installed in an apartment building cannot be checked in real time, so it is difficult to identify the location of a fire accurately. Protected areas are also not assigned to each household, and residents cannot be clearly informed of the occurrence of a fire. As a consequence, safety evacuation cannot be secured. In addition, it is impossible to test the operation performance for water detectors in sprinkler fire extinguishing systems outside of the household. Therefore, an experiment was conducted to evaluate the performance of a remote fire supervisory system. The results show that the system satisfies all performance requirements. Also, an household alarm system was installed in each household to alert of any occurrence of a fire accurately, and the performance of the alarm system was improved to ensure that residents were quickly evacuated.

A Study on the Safety Management Standards and Safety Indicators Private Lodging in Farming and Fishing Villages in Rural Area (농어촌민박의 안전관리 기준 및 안전지표에 관한 연구)

  • Suh, hey-sung;Lee, Yong-soo;Kim, Youna-ah
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Various support is provided for the increase in the number of private lodging users in farming and fishing villages and related government policies. However, the bed-and-breakfast accommodation in rural areas lack safety standards or safety indicators for the service pension Gangneung, carbon monoxide leak accident in December 2018, 2020 East Sea in January, Pension. Large gas explosion, accident and is threatening the security of their citizens. Unlike lodging facilities, private lodging in farming and fishing villages is allowed to operate with certain requirements such as fire extinguishers and fire alarms. The purpose of this study is to present safety standards and safety indicators for lodging facilities in farming and fishing villages, which are necessary for the operation management and inspection of local governments and the government related to lodging in farming and fishing villages. Through the study, safety management areas of private lodging in farming and fishing villages were divided into facility safety, fire safety, food safety and living safety, and detailed inspection indicators were presented. There is an academic implication that research on safety management of lodging facilities has been expanded through safety research in areas related to private lodging in farming and fishing villages. It has practical implications in that it provides management standards and indicators that can be used for safety management of private lodging in farming and fishing villages. The limitations of this study are that more studies on private lodging in farming and fishing villages are expected to be conducted through the results of this study, and the lack of research on accommodation safety has prevented more detailed indicators from being derived.

Analyzing the Current State of Commercial Mobile Network Communication Systems for Mountain Disaster Response (산지 재난대응을 위한 상용 이동통신망 통신체계 현황분석)

  • Sihyeong Lee;Jungrim Ryu;Minho Baek
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.3
    • /
    • pp.654-662
    • /
    • 2024
  • Purpose: This study analyzes the current status of open coverage of commercial mobile communication networks, which is an indicator for determining whether the disaster safety communication network call area is secured in mountainous areas, with the aim of more stable operation of the disaster safety communication network. Method: We measured the perceived communication quality on forest roads in a large mountainous area in Samcheok City and compared it with the publicly available commercial cellular network coverage data of three telecommunications companies after spatial overlapping, and found that there was a spatial mismatch between the publicly available commercial cellular network coverage and the perceived communication quality measurement results. Result and Conclusion: Therefore, for the stable operation of the disaster safety communication network in mountainous areas, it is necessary to secure additional PS-LTE mobile base stations and take measures to improve the accuracy of publicly available commercial mobile network coverage.

Fire Risk Index and Grade Evaluation of Combustible Materials by the New Chung's Equation-XII (새로운 Chung's equation-XII에 의한 연소성 물질의 화재위험성지수 및 등급 평가)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.388-396
    • /
    • 2023
  • The evaluation of fire risk for combustible materials was carried out using Chung's equations-X, Chung's equations-XI, and Chung's equation-XII, which were newly established. The fire risk index-XII (FRI-XII) and fire risk rating (FRR) were calculated for specimens including camphor tree, cherry, rubber tree, and elm. The combustion characteristics were determined using a cone calorimeter according to ISO 5660-1. Chung's equations caculated the fire performance index-X (FPI-X) and fire growth index-X (FGI-X) values ranged from 89.34 to 1696.75 s2 /kW and from 0.0006 to 0.0107 kW/s2 , respectively. In addition, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) varied from 0.08 to 1.48 and from 0.67 to 11.89, respectively. The fire risk index-XII (FRI-XII), which is an indicator of fire risk, showed that camphor tree had a value of 148.63 (fire risk rating: G), indicating a very high fire risk. This suggests that combustible materials with a high concentration of volatile organic compounds have lower FPI-X and FPI-XI values, higher FGI-X and FGI-XI values, and consequently higher FRI-XII values, indicating an increased fire risk.

Students', Teachers', and Parents' Safety Concerns Affecting Students' Safety Behaviors of Elementary Schools in Korea (학생, 부모, 교사의 안전 관심도가 초등학교 어린이의 안전행동에 미치는 영향)

  • Lee, Myung-Sun
    • Korean Journal of Health Education and Promotion
    • /
    • v.22 no.4
    • /
    • pp.41-56
    • /
    • 2005
  • Objectives: More than 80% of unintentional injury was related to risk-taking behaviors involved in child accidents. Therefore, diverse care and concerns on safety should be provided from teachers as well as parents to build child safety behaviors. The purpose of this study was to identify the effects of safety concerns from students, teachers, and parents on elementary students' safety behaviors in Korea. Methods: The 5th and 6th grade students participated in this study in 14 elementary schools in Korea and the total number of students was 1,033. The study schools were selected by the stratified cluster sampling method throughout 7 metropolitan areas in Korea. Data were collected by the self-administered survey and the questionnaires were delivered to the vice-principals of the designated schools by ground postal service and the vice-principals conducted survey data collection. The questions on students' safety concerns, teachers' safety concerns, parents' safety concerns, safety practices, safety education, and demographics were included in the survey. All survey responses were encoded into SPSS program and t-test, ANOVA, and multiple regression analysis were utilized. Results: The students taking accidents one time more per year were more than 60% and the two thirds of them recognized that their accidents were due to their risk behaviors. Parents' education on safety practices was more frequent than teachers' education; furthermore, teachers' concerns on safety behaviors were poorer than students' or parents' concerns. In terms of safety behaviors, the scores of fire and home-related safety behavior were high but the scores of traffic and bicycle, in particular, helmet wearing practice were low. Three concerns from students, parents, and teachers all were significantly related to children's safety behaviors. Conclusions: In conclusion, safety concerns from the close networks are the important indicator of child safety behaviors and, the safety training programs, therefore, for parents and teachers as well as for students need to be developed for improving children's safe behaviors.

A Study on the Utilization of Safety Practice Index to Increase the Effectiveness of Safety Management (안전관리 실효성 증대를 위한 안전실천지수 활용 방안 연구)

  • Kim, Heon-Seok;Kim, Jong-In;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.1
    • /
    • pp.44-49
    • /
    • 2021
  • Domestic industrial accidents continue to increase, with 2,142 deaths in 2018, up by 185 (9.5%) from 1,957 deaths in 2017. Industrial accidents that cause loss of human lives pose a serious risk to businesses because of the strengthening of safety regulations and the changing public perception of social responsibility. Accordingly, to prevent industrial accidents, companies regularly conduct onsite safety activities and conduct education and training to raise awareness among employees. However, many such corporate activities are not conducted voluntarily and practically by employees but mostly by formal implementation. To discontinue this customary and passive behavior of employees and establish a mature safety culture, strengthening the execution power of safety management at the site is of paramount importance, and to this end, we aim to utilize the safety practice index (SPI). In this study, the SPI calculated on the basis of the results of the 2018 and 2019 risk management and safety activities of a site was compared with the reported safety accidents. The results confirmed that the SPI index can be used as a valid indicator for safety activities for accident prevention, such as strengthening leadership and safety policies to grade and manage safety management levels for a certain period of time or by a department or to convert weaknesses into strengths.