• Title/Summary/Keyword: Fire Safety Design

Search Result 676, Processing Time 0.026 seconds

Proposal of Legislation of Smoke Compartment for Prevention and Control of Smoke Diffusion in Buildings (건축물의 연기확산 방지 및 제어를 위한 방연구획의 법제화 제안)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Kim, Hye-Won
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.96-97
    • /
    • 2019
  • According to building law, there are only regulations on the fire prevention compartments that can perform the function of partial smoke compartment, but the building law management of the smoke compartment for effective smoke diffusion prevention and control is not possible. The lack of control on the smoke compartment such as leakage rate on the penetrating part, and the lack of leakage rate in the design of smoke control of fire safety law resulted in the absence of fundamental safety technology. Therefore, this study seeks to find solutions to domestic problems after reviewing relevant domestic laws and regulations.

  • PDF

Estimating Door Open Time Distributions for Occupants Escaping from Apartments

  • Hopkin, Charlie;Spearpoint, Michael;Hopkin, Danny;Wang, Yong
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 2021
  • The door open time, resulting from occupants evacuating from apartments, is an important parameter when assessing the performance of smoke ventilation systems in high-rise apartment buildings. However, the values recommended in UK design guidance appear to have limited substantiation. Monte Carlo simulations have been carried out considering variabilities in door swing time, flow rate and number of occupants. It has been found that the door open time can be represented by a lognormal distribution with a mean of 6.6, 8.7 and 11.1 s and a standard deviation of 1.7, 3.2 and 4.7 s for one, two and three-bedroom apartments, respectively. For deterministic analyses, it is proposed that the 95th percentile values may be adopted in line with recommended practice for other fire safety design parameters such as fuel load density and soot yield, giving door open times of 10 s to 19 s, depending on the number of bedrooms.

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Flow Rate of Supply and Leakage (보충량과 누설량을 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. As one of the fire safety standards designed to secure the smoke safety, NFSC501A (Design Guide for Smoke Control System of Special Evacuation Stairwell and Lobby) has been proposed, preventing smoke from penetrating into the smoke-free escape route by raising the pressure of the smoke control zone higher than fire area. For model building of 20 stories, pressurization system was designed according to standard and pressure field of compartments in whole building induced by pressurization system was analyzed using the network model.

Overview of Fire Safety onboard International Space Station(ISS): Characteristics of Flame Ignition, Shape, Spread, and Extinction in Microgravity (국제우주정거장 화재안전 연구개괄: 마이크로중력화염의 특성(점화/형상/전파/소멸특성))

  • Park, Seul-Hyun;Hwang, Cheol-Hong
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.21-29
    • /
    • 2012
  • Due to a significant leap in the science and technology, the manned space exploration that has started with suborbital flights is now being expanded into the deep space. The space superpowers such as the U.S. and Russia have been making an effort to further develop the manned space technology. Among such technologies, the fire safety technology in microgravity has recolonized as one of the most critical factors that must be considered for the manned space mission design since the realistic fire broke out onboard the Mir station in 1997. In the present study, the flame characteristics such as flame ignition, shape, spread, and extinction that are critical to understand the fire behavior under microgravity conditions are described and discussed. The absence of buoyancy in microgravity dominates the mass transport driven by diffusiophoretic and thermophorectic fluxes (that are negligible in normal gravity) and influences the overall flame characteristics-flame ignition, shape, spread, and extinction. In addition, the cabin environments of the pressurized module (PM) including the oxygen concentration, ambient pressure, and ventilation flow(which are always coupled with microgravity condition during the ISS operation) are found to be the most important aspects in characterizing the fire behavior in microgravity.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.

Experimental study on cyclically-damaged steel-concrete composite joints subjected to fire

  • Ye, Zhongnan;Jiang, Shouchao;Heidarpour, Amin;Li, Yingchao;Li, Guoqiang
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.351-364
    • /
    • 2019
  • Earthquake and fire are both severe disasters for building structures. Since earthquake-induced damage will weaken the structure and reduce its fire endurance, it is important to investigate the behavior of structure subjected to post-earthquake fire. In this paper, steel-concrete composite beam-to-column joints were tested under fire with pre-damage caused by cyclic loads. Beforehand, three control specimens with no pre-damage were tested to capture the static, cyclic and fire-resistant performance of intact joints. Experimental data including strain, deflection and temperature recorded at several points are presented and analyzed to quantify the influence of cyclic damage on fire resistance. It is indicated that the fire endurance of damaged joints decreased with the increase of damage level, mainly due to faster heating-up rate after cyclic damage. However, cracks induced by cyclic loading in concrete are found to mitigate the concrete spalling at elevated temperatures. Moreover, the relationship between fire resistance and damage degree is revealed from experimental results, which can be applied in fire safety design and is worthwhile for further research.

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.

A Study on PBD case of Evacuation in Japan for PBD Approach of Korea. (국내 PBD 기술의 정립을 위한 해외 성능적 피난안전설계사례에 관한 조사)

  • Kim, Dong-Eun;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.322-327
    • /
    • 2008
  • Fire safety provisions have to be determined through Performance -based design in many project. There is a need for quick estimation of evacuation time for scenario analysis in hazard assessment. The key equations on estimating evacuation time have to be known. In Japan There are many experience of PBD according to the Architectural law. It is the aim of this study to investigate the PBD case of Evacuation in Japan for PBD Approach of Korea.

  • PDF

Reliability of the Performance-Based Design: International Cases (성능위주설계의 신뢰성 확보를 위한 외국 사례 검토)

  • Hwang, Jun-Ho;Moon, Sung-Woong;Choi, Kyu-Chool;Ryu, Sang-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.151-154
    • /
    • 2011
  • 법률 중심적인 사양위주 설계의 한계를 극복하고자 국내 외 다양한 분야에서 성능위주 설계가 사용되고 있다. 국내에 도입된 소방 설비에 대한 성능위주 설계는 도입단계로 볼 수 있어, 선진국의 사례를 통해 도입 초기인 현재 발생할 수 있는 문제점과 대안을 분석하였다.

  • PDF

AN OVERVIEW OF THE FINDINGS OF THE Combustion Behaviour of Upholstered Furniture PROJECT

  • Grayson, Stephen J;Sundstrom, Bjorn;Van Hees, Patrick
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.93-103
    • /
    • 1997
  • This paper gives an overview of the CBUF project. The work described is the collective effort of 11 CBUF partners, laboratories, universities, industries, in 8 countries. It became possible to do this research thanks to the European Commission interest in the burning behaviour of upholstered furniture and their willingness to sponsor this large effort. The opportunity to work with the many of the most prominent fire researchers and furniture experts have been extremely rewarding. All the expertise of these scientists have resulted in a lot of research results that are presented. The article only gives the main findings and conclusions of the project, namely the presentation of the fire safety design procedure of the CBUF project. Other articles will deal with specific modelling topics and an extensive description of the project can be found in the final CBUF report EUR 16477 EN.

  • PDF