• Title/Summary/Keyword: Fire Risk Analysis

Search Result 496, Processing Time 0.03 seconds

Risk Analysis of Jet Flame Occurred at Hydrogen Fuel Cell Vehicle (수소자동차의 제트화염 발생에 따른 위험성 분석)

  • Byoungjik, Park;Yangkyun, Kim;Ohk Kun, Lim
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.158-165
    • /
    • 2022
  • Eco-friendly policies proposed by the government of The Republic of Korea have encouraged the use of eco-friendly vehicles. Hydrogen vehicles have exhibited the highest growth rate, although the current number of registered vehicles is low. In hydrogen vehicles, a thermally activated pressure relief device (TPRD) is installed to prevent explosions in the hydrogen gas cylinder. When discharged due to low ignition energy, hydrogen gas readily forms a jet flame. The risks induced by such jet flames were analyzed through a numerical analysis. Jet flames can activate TPRDs installed in nearby hydrogen gas cylinders. As a result, high-voltage cables exposed in the lower area of a vehicle can ignite within seconds. There was a 9.5-kW/m2 area around the vehicle (which can result in casualties) at a distance of ~5 m from the hydrogen gas cylinder, and a 37.5-kW/m2 area (which can cause significant damage) in the form of an inverted triangle toward the lower section of the vehicle. We believe that the risk factors analyzed herein should be considered for addressing accidents in hydrogen vehicles.

Experimental study on the combustion characteristics of titanium alloy (티타늄 합금 폐기물의 연소 특성에 관한 실험적 연구)

  • Lee, Jun-Sik;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • Most titanium alloy waste with cutting oil was discarded without recycling process so that it can be caused by metal and oil fires. However, there is no fire management system and studies on the titanium or titanium alloy waste in spite of high fire risk. The purpose of this experimental study is to identify the fire risk of the titanium alloy waste with cutting oil. We collected the 120g waste which was made in the biomedical titanium alloy cutting process. The waste was burned and conducted thermal image analysis with infrared camera. The experimental results which illustrated the process, characteristics, and trends of fire are presented. Firstly, the cutting oil was burned and partially the titanium alloy waste was burned. The maximum temperature of the fire was more than $650^{\circ}C$ in some specific spots. These results means when a lot of titanium alloy waste with cutting oil was ignited, this fire could connect the titanium fire. In other words, the fire has a flammable liquid fire and combustible metal fire at the same time. The experimental study could be used fire prevention, response, and investigation of the titanium alloy waste.

Risk Prediction and Analysis of Building Fires -Based on Property Damage and Occurrence of Fires- (건물별 화재 위험도 예측 및 분석: 재산 피해액과 화재 발생 여부를 바탕으로)

  • Lee, Ina;Oh, Hyung-Rok;Lee, Zoonky
    • The Journal of Bigdata
    • /
    • v.6 no.1
    • /
    • pp.133-144
    • /
    • 2021
  • This paper derives the fire risk of buildings in Seoul through the prediction of property damage and the occurrence of fires. This study differs from prior research in that it utilizes variables that include not only a building's characteristics but also its affiliated administrative area as well as the accessibility of nearby fire-fighting facilities. We use Ensemble Voting techniques to merge different machine learning algorithms to predict property damage and fire occurrence, and to extract feature importance to produce fire risk. Fire risk prediction was made on 300 buildings in Seoul utilizing the established model, and it has been derived that with buildings at Level 1 for fire risks, there were a high number of households occupying the building, and the buildings had many factors that could contribute to increasing the size of the fire, including the lack of nearby fire-fighting facilities as well as the far location of the 119 Safety Center. On the other hand, in the case of Level 5 buildings, the number of buildings and businesses is large, but the 119 Safety Center in charge are located closest to the building, which can properly respond to fire.

A Study on Disaster Prevention and Risk Assessment System Applying Combustion Velocity at Traditional Housing Zone (전통건축물보존지구내에서의 연소속도식을 고려한 방재계획의 수립과 재난위험도평가 시스템 구축에 관한 연구)

  • 김희성;노삼규
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2001
  • The purpose of this study is to set up disaster prevention plan and risk assessment system considering combustion velocity at traditional housing zone. The combustion velocity analysis could contribute to build in disaster prevention technique through the potential risk analysis of the area, such analysis also able to set up comprehensive disaster prevention management system. Following results have achieved through the combustion velocity calculation. \circled1 The combustion velocity was calculated in order of the below winds, the above winds and the side winds. \circled2 It must be careful to set up disaster prevention plan in case of the below winds. \circled3 The combustion velocity was calculated at the density Bone where neighboring Distance and Length was small. \circled4 It proved that factors of each parameter not mostly effect to analyse the combustion velocity in limit of the 30 minutes after ignition. \circled5 At the density zone where Distance and Length is small the duration of transfer to neighboring house takes up to 4 minutes, it is required to set up of emergency response plan to minimize the fire dispersion.

  • PDF

A Study on Analysis Method of Fire path for Shipping Chemical (선박적재 화학물의 화재사고 경로 분석기법에 관한 고찰)

  • Kang, Yu-Mi;Yang, Hyeongsun;Park, Deuk-Jin;Yim, Jeong-Bin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.267-267
    • /
    • 2019
  • The purpose of this study is to understand the risk of chemical product, Styrene Monomer(SM), shipped in a vessel. SM is harmful chemical product which can make injury, explosion and/or fire in a vessel. The understand of SM risk is very important to protect seafarer's body and vessel safety. This research can be expected that the understanding of SM risk by a seafarer's to prevent accidents by SM explosion/fire. In this study we used event tree analysis method using chemical reaction cased by explosion. As a result, we founded various chemical reaction and visualization for explosion path.

  • PDF

An Experimental Study for Vertical Flame Spread Analysis of Aluminum Composite Panel (알루미늄 복합 패널의 수직 화염전파속도 분석을 위한 실험적 연구)

  • Kim, Il-Kwon;Kim, Bong-Chan;Ku, In-hyuck;Seo, Dong-Gu;Lim, Nam Gi;Kwun, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.315-317
    • /
    • 2013
  • To analyze vertical fire spreadability of aluminum composite panel, real scale test of aluminum composite panel and fire retardant aluminum composite panel was conducted as well as analysis of domestic code, test and domestic reaserch resulted in following conclusion. Fire spread risk assessment of aluminum Composite Panel is impossible with the current regulations (Cone Calorimeter Test). It need to changes of regulatory and combustion expanded risk assessment and regulatory changes in the test methods need to be judged. Also, there is quite a big different between the general aluminum Composite Panel and semi-non combustible of aluminum Composite Panel. However it is also deemed to be danger when present in the sidewall to the top consisting of fire spread. From now on, it is needed the study about interpretation of fire spread and sidewall of vertical fire spread analysis not only experiments for aluminum Composite Panel.

  • PDF

Beliefs of University Employees Leaving During a Fire Alarm: A Theory-based Belief Elicitation

  • Christopher Owens;Aurora B. Le;Todd D. Smith;Susan E. Middlestadt
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.201-206
    • /
    • 2023
  • Background: Despite workplaces having policies on fire evacuation, many employees still fail to evacuate when there is a fire alarm. The Reasoned Action Approach is designed to reveal the beliefs underlying people's behavioral decisions and thus suggests causal determinants to be addressed with interventions designed to facilitate behavior. This study is a uses a Reasoned Action Approach salient belief elicitation to identify university employees' perceived advantages/disadvantages, approvers/disapprovers, and facilitators/barriers toward them leaving the office building immediately the next time they hear a fire alarm at work. Methods: Employees at a large public United States Midwestern university completed an online cross-sectional survey. A descriptive analysis of the demographic and background variables was completed, and a six-step inductive content analysis of the open-ended responses was conducted to identify beliefs about leaving during a fire alarm. Results: Regarding consequence, participants perceived that immediately leaving during a fire alarm at work had more disadvantages than advantages, such as low risk perception. Regarding referents, supervisors and coworkers were significant approvers with intention to leave immediately. None of the perceived advantages were significant with intention. Participants listed access and risk perception as significant circumstances with the intention to evacuate immediately. Conclusion: Norms and risk perceptions are key determinants that may influence employees to evacuate immediately during a fire alarm at work. Normative-based and attitude-based interventions may prove effective in increasing the fire safety practices of employees.

Methods for Nonlinear Structural Response Analysis of Offshore Structures with Passive Fire Protection under Fires (해양플랜트 구조물의 화재 사고 시 PFP 효과를 고려한 비선형 구조응답 해석 기법에 대한 연구)

  • Kim, Jeong Hwan;Lee, Dong Hun;Ha, Yeon Chul;Kim, Bong Ju;Seo, Jung Kwan;Paik, Jeom Kee
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.294-305
    • /
    • 2014
  • In offshore structures, fire is one of the most important hazardous events. The concern of fires has recently been reflected in the rules and quantified risk assessment based design practice. Within the framework of quantified risk assessment and the management of offshore installations, therefore, more refined computations of the consequences or hazardous action effects due to fire are required. To mitigate fire risk, passive fire protection(PFP) is widely used on offshore structures. This study presents methods for a nonlinear structural response analysis considering the PFP effects under fires. It is found that a structural response analysis is most likely to use valuable technology for the optimization and design of offshore structures with PFP. Thermal and structural response analyses have been performed using LS-DYNA and FAHTS/USFOS. The results of these structural response analyses are compared with each other.

A Study on Fire Spread and Evacuation Risk of Conduit Combustion in Ceiling Hiding Place (천장 은폐장소 전선관 연소에 따른 화재확산 및 피난 위험도에 관한 연구)

  • Park, Kwang-Muk;Jeon, Jae-Kam;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.55-65
    • /
    • 2020
  • In this study, the ISO 5660 and ISO 5659 combustion tests were conducted with synthetic resin conduits (CD, VE) and metal conduit (ST) used for wiring work in electrical facilities, which can be installed in ceiling concealed places. Then, fire spreading and evacuation risks were analyzed based on the measured data. In the ISO 5660 test, CD of 120.5 MJ/㎡, VE of 81.9 MJ/㎡, and ST of 4.9 MJ/㎡ were measured. In the ISO 5659 test, the CD 1320, VE 731, and ST 102 were measured, and then the maximum smoke densities were measured for CD 605 s, VE 740 s, and ST 1,200 s. In terms of fire spreading and evacuation risk, the CD conduit, VE conduit, and ST conduit were in order. In the fire spreading risk analysis, total heat emission was calculated as 4,820 MJ/㎡, 4,267 MJ/㎡, and 196 MJ/㎡ for CD, VE, and ST, respectively. Evacuation risk analysis shows at transmittance of 89%, CD is 127 s, VE is 35 s, and ST is 969 s. At transmittance of 79%, representing almost invisible concentration, CD is 157 s and VE is 50 s. The CD and VE conduits had a high fire spreading and evacuation risks, while the ST conduit had little effect on fire spreading and evacuation risk.

A Study on the Fire Simulation for Vertical Fire Diffusion Analysis of Jecheon Sports Center (제천스포츠센터의 수직 화재확산 해석을 위한 화재시뮬레이션 분석에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.79-80
    • /
    • 2022
  • In December 2017, a fire at the Jecheon Sports Center caused 29 deaths and 40 injuries, and about 2 billion won in property damage. It is a facility used by unspecified people as a publicly used establishment with a piloti structure. The damage was expanded due to the ignition of combustible exterior materials, Lack of fire protection in horizontal and vertical penetrations. Although legislation has improved since the fire, it is not retroactively applied, increasing the risk of fire in existing buildings. Accordingly, it is necessary to examine the case of the Jecheon Sports Center fire and draw out the problems. In this study, the fire simulation results and the Jecheon Sports Center fire are comparatively analyzed and used as basic data for fire reduction measures in publicly used establishment. As a result of the fire simulation drive, in the case of the second floor, the room temperature exceeded the human life safety standard of 60 ℃ after about 700 seconds had passed. In the case of three floor, it is predicted that the indoor temperature will exceed about 350 ℃. and temporary complexation will occur in the indoor combustibles.

  • PDF