• Title/Summary/Keyword: Fire Risk Analysis

Search Result 502, Processing Time 0.024 seconds

A study on the Risks of Using Filtration Facilities at the Organic Light Emitting Diode(OLED) and Its Preventive Measures (유기발광다이오드(OLED) 소재 제조 현장 여과 설비사용 위험성 및 개선 방안 연구)

  • Jong-Ku Kwak;Chankyu Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.1-11
    • /
    • 2023
  • The size of the OLED material market is expected to grow from $1.1 billion in 2019 to $2.3 billion in 2023, with an average annual sustainable growth of more than 19%. Among the facilities mainly used by OLED material manufacturers, accidents such as fire, explosion, and leakage frequently occur when using filtration equipment, so it is necessary to improve the risk when using filtration equipment. In this study, it was divided into four main processes, namely, assembly and disassembly process, filtration process, wet cake recovery process, and washing process in order to derive the risks associated with the use of filtration equipment. Hazard factors were derived by conducting accident case investigations, preliminary interviews, and surveys. For the analysis of questionnaire results, statistical analysis such as frequency analysis and Pearson chi-square test analysis was performed using SPSS 21, and risk improvement measures were suggested using the analyzed results. It is expected that this study will serve as a basis for dealing with safety and risk factors that may occur as the size of the OLED market expands.

Comparative Analysis between a Real-Life Explosion Case and A Damage Prediction Program (J도 LPG충전소 가스 누출로 인한 폭발사례와 피해예측 프로그램의 비교 분석)

  • Yongho Yang;Soonju Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.3
    • /
    • pp.59-70
    • /
    • 2024
  • This study aims to estimate the scope of damage impact with a real-life explosion case and a damage prediction program (ALOHA) and suggest measures to reduce risk by comparing and analyzing the results using a Probit model. After applying it to the ALOHA program, the toxicity, overpressure, and radiant heat damage of 5 tons of storage scopes between 66 to 413 meters, and the real-life case also demonstrated that most of the damage took place within 300 meters of the LPG gas station. In the Probit analysis, the damages due to radiant heat were estimated as first-degree burns (13-50%), while structural damage (0-75%) and glass window breakage (94-100%) were expected from overpressure, depending on the storage volume. After comparing the real-life case and the damage prediction program, this study concluded that the ALOHA program could be used as the scope of damage impacts is nearly the same as the actual case; it also concluded that the analysis using the Probit model could reduce risks by applying calculated results and predicting the probability of human casualties and structural damages.

Analysis of Psychological and Physiological Changes According to the Experience of the Care Farm of Fire-fighters (소방공무원의 치유농장 체험 활동에 따른 심리·생리적 변화 분석)

  • Jang, Hye Sook;Yoo, Eunha;Kim, Jeong Hee;Jeong, Sun-Jin;Kim, Jae Soon;Ryu, Doo Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.27 no.1
    • /
    • pp.71-83
    • /
    • 2021
  • This study conducted a survey and analysis of saliva cortisol and psychological questionnaire in order to find out the psychological and physiological changes according to the experience of the care farm targeting fire-fighters. In the program to experience care farms, the total cortisol concentration as a stress hormone decreased after participation, and there was a statistically significant difference (z = 2.858, p <.01). As a result of the risk distribution analysis of the level of post-traumatic stress symptoms of firefighting officials who participated in the program to experience care farms, the high-risk group was found to be as high as 31.2%. In addition, the relative explanatory power of the independent variables that influence the loyalty of the care farm experience activity was found to have an effect in the order of program satisfaction, age, and reliability, and among them, program satisfaction was found to be the most influential variable. Therefore, it is believed that the care farm experience activities as the application of the healing program will have a positive effect on the activation of care farms in each region and the relief of stress symptoms of fire-fighters.

Assessing the risk of work-related musculoskeletal disorders in 119 EMT: a focus on patient-carrying tasks (119구급대원의 업무 관련성 근골격계 질환 위험성 평가 : 환자 운반 작업을 중심으로)

  • Jeong-Won Son
    • The Korean Journal of Emergency Medical Services
    • /
    • v.27 no.3
    • /
    • pp.33-46
    • /
    • 2023
  • Purpose: This study aims to evaluate the risk of work-related musculoskeletal disorders (WMSDs) in 119 EMT during patient-carrying tasks using a long backboard (LBB) and a variable stretcher. Methods: Manikins were used as patients, and 45 new 119 EMT from K Fire Academy were filmed performing patient-carrying tasks on stairs. The tasks were analyzed using Ovako working posture analysis system (OWAS) and Rapid entire body assessment (REBA). Results: In using LBB, the OWAS score was Mode 3(Mean 2.37, Maximum 3), requiring as soon as possible corrective action, the REBA score was Mode 11(Mean 9.16, Maximum 11), requiring immediate improvement. In using variable stretcher, the OWAS score was Mode 1(Mean 2.33, Maximum 3), non-necessity for corrective action, the REBA score was Mode 9(Mean 8.0, Maximum 11), requiring as soon as possible. Conclusion: In conclusion, improvement was needed in one task (carrying a patient using a LBB) in the OWAS and in two tasks (carrying a patient using a LBB, carrying a patient using a variable stretcher) in the REBA. Thereby, required attention and management of WMSDs during training. In addition, it is essential to carry out objective and quantitative assessments through ergonomic analysis by occupational health professionals when designing future training programs to prevent WMSDs.

Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System (BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석)

  • Seok-Hwan Cho;Jae-Sub Ko;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

Sensitivity analysis of input variables to establish fire damage thresholds for redundant electrical panels

  • Kim, Byeongjun;Lee, Jaiho;Shin, Weon Gyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.84-96
    • /
    • 2022
  • In the worst case, a temporary ignition source (also known as transient combustibles) between two electrical panels can damage both panels. Mitigation strategies for electrical panel fires were previously developed using fire modeling and risk analysis. However, since they do not comply with deterministic fire protection requirements, it is necessary to analyze the boundary values at which combustibles may damage targets depending on various factors. In the present study, a sensitivity analysis of input variables related to the damage threshold of two electrical panels was performed for dimensionless geometry using a Fire Dynamics Simulator (FDS). A new methodology using a damage evaluation map was developed to assess the damage of the electrical panel. The input variables were the distance between the electrical panels, the vertical height of the fuel, the size of the fire, the wind speed and the wind direction. The heat flux was determined to increase as the vertical distance between the fuel and the panel decreased, and the largest heat flux was predicted when the vertical separation distance divided by one half flame length was 0.3-0.5. As the distance between the panels increases, the heat flux decreases according to the power law, and damage can be avoided when the distance between the fuel and the panel is twice the length of the panel. When the wind direction is east and south, to avoid damage to the electrical panel the distance must be increased by 1.5 times compared to no wind. The present scale model can be applied to any configuration where combustibles are located between two electrical panels, and can provide useful guidance for the design of redundant electrical panels.

Study of the Risk of Ignition due to Internal Combustion Engines in Areas with Potentially Explosive Gas Atmospheres (잠재적 폭발위험장소에서 내연기관에 의한 점화 위험성에 관한 연구)

  • Kim, Yun Seok;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.1-8
    • /
    • 2016
  • Safety management in hazardous areas with potentially explosive gas atmospheres (here in after referred to as hazardous areas) in large scale facilities dealing with combustible or flammable materials at home and abroad is very important (significant) for the coexistence of the company and local society based on business continuity management (BCM) and reliance. For the safety management in hazardous areas, two systems are mainly used: (1) the control system for the prevention of combustible or flammable substances and (2) the explosion proof system for the elimination of ignition sources when flammable gases are leaked to inhibit the transition to fire or explosion accidents. While technology and regulations on explosion proof facilities or devices for electrical ignition sources are well developed and defined, those for thermal ignition sources need to be more developed and established. In this study, the internal combustion engine in hazardous areas was investigated to determine the risk of ignition. For this purpose, document searches were conducted on the relevant international standards and accidents cases and risk analysis reports. In addition, this study assessed the application cases of the diesel engine's safety equipment, such as spark arresters regarding the site of process safety management (PSM) system in central Korea. To practically apply these results to the hydrocarbon industry, the safety management method for explosion prevention in hazardous areas was provided by risk identification for ignition sources of internal combustion engines, such as diesel engines.

Risk Perception and Safety Knowledge of Scuba Divers

  • Cho, Byung-Jun;Ko, Jang-Sik;Kim, Gyoung-Yong;Kim, Yong-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.131-137
    • /
    • 2019
  • This study was aimed to identify a study on risk perception and safety knowledge and awareness of scuba diver. In order to achieve this purpose, a total of 310 customers over the age of 20 were selected as study participants form diving pools and dive resort in Seoul, Gyeonggi, Gangwon, Gyeongsang area using the convenience sampling method. However, only data from 295 customers were used after screening the data for reliability. The instrument for data collection was a questionnaire, and descriptive statistics, inter-item consistency reliability, t-test, ANOVA, post hoc test, correlation analysis, pearson chi-square test were conducted on the data using the SPSS 21.0 version statistical package program. The followings are the results: First, risk perception differs significantly according to age, education level, occupation and participation period. Second, participation period and safety knowledge have positive correlation.

A Study on Types of Disasters Affecting City Safety (도시안전에 영향을 미치는 재난유형에 관한 연구)

  • Choi, Yun-Cheul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.93-100
    • /
    • 2019
  • Modern society is transforming into an extreme climate environment. This is fatal to humans and ecosystems and is expected to cause large-scale damage. As this spokesman, natural disasters are increasing as this global average temperature rises. Social and economic damage by this tendency is also increasing. In addition, the frequency and scale of social disasters are increasing. Damage to the living area due to the damage of the infrastructure due to the increased reliance on infrastructure has been increasingly enlarged. In this research, various disasters such as natural disasters and social disasters analyze the impact on urban safety. A local autonomous entity K Priority Management Establish a kind of disaster, prepare crisis management manual, and use it as a basic material of education / training.

Night fire fighting helicopters operations and Aviation Safety (야간산불진화 헬기 운영과 항공안전)

  • Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.1
    • /
    • pp.145-151
    • /
    • 2014
  • Not only in Korea, but also in other countries, most helicopter accidents occur at low altitude. Analysis on accidents data collected both in Korea and other countries has brought two conclusions. Firstly, helicopter operations during the night hours carries a high risk. Secondly, the most common cause of night hour operations is loss of control due to the flight illusion. As an operation relying on a night vision in particular has a very high accident hazard, accompanying instruments such as NVG are ought to be provided. Hence, a thorough preparation and inspection on missions for night forest fire extinguishing should be required and perfect guidelines/road maps and enough training programs for the operation should be provided before the engagement in missions.