• Title/Summary/Keyword: Fire Risk Analysis

Search Result 496, Processing Time 0.029 seconds

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.

The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder (화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석)

  • Kim, Jong Yoon;Jeon, Yong Han
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.253-260
    • /
    • 2015
  • In this study, using the FDS as the fire simulation and evacuation simulations of the Pathfinder, set the main control room of the building to the fire point fire safety assessment studies were carried out. At first the quantitative result such as distribution of visibility as time passing, distribution of temperature, distribution of CO density produced results using fire-simulation and evacuation-simulation was carried out based on the result that produced the final safety evaluation result as being calculated of evacuation time. As the risk increased with the distribution of visibility at the result of fire-simulation, evacuation-simulation was carried out using the result. Finally the result was made 127.9 sec that everyone could evacuate. The numerical results are analyzed in case of the places in the building required safe egress time for safety a as the analysis to be no more than available safe egress time was analyzed to be secured. The results of this safety evaluation represent that more smooth evacuation safety performance can be secured by linking the event of fire firefighting equipment as a result of simulating the worst conditions.

  • PDF

Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel (중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.9-17
    • /
    • 2016
  • In the case of a medium length road tunnel, the installation of a smoke control facility is not mandatory so users can suffer considerable injuries if a fire breaks out. Therefore, this study analyzed the high-temperature air and toxic gas generated by fire proliferating with time when a smoke barrier is not installed and when the installation interval is 100, 150, 200, and 250 m through 3-dimensional numerical analysis, evacuation simulation, and Quantitative Risk Assessment Methodology targeting the medium length road tunnel. As a result, the diffusion of the high-temperature air and toxic gas occurring from the a fire was delayed when the smoke barrier was installed in a medium length road tunnel compared to that when it was not installed. In addition, when the installation interval of a smoke barrier was 100m and the numerical analysis target was 100m, the diffusion of high-temperature air and toxic gas generated by the fire was delayed more than in the other cases, which was most suitable for tunnel users to evacuate.

A Systematic Review and Meta-Analysis of Fire Needling Treatment for Knee Osteoarthritis: Focused on Comparative Studies with Manual Acupuncture Treatment during Recent Five Years (퇴행성 슬관절염의 화침 치료에 대한 체계적 문헌 고찰 및 메타분석: 최근 5년간의 호침 치료 비교 연구를 중심으로)

  • Ko, Hong-Je;Yoo, Jae-Hee;Shin, Jeong-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.36 no.2
    • /
    • pp.104-114
    • /
    • 2019
  • Objectives : The purpose of this study is to review the effectiveness of fire needling treatment for knee osteoarthritis in comparison with manual acupuncture treatment. Methods : Through four foreign online databases (PubMed, Cochrane library, EMBASE, and CNKI) and five domestic online databases (NDSL, RISS, KISS, OASIS, and KTKP), we searched for clinical studies that performed fire needling treatment for knee osteoarthritis until May 10, 2019. Only randomized controlled trials were selected and we assessed the risk of bias according to the Cochrane RoB criteria. This review examined the selected studies into first author, publication year, sample size, outcome measurements, results, acupoints, treatment time & period and so on. Results : A total of 7 RCTs were selected in this review and all were conducted in China. Treatment period of more than 4 weeks and treatment visits of 10 to 20 times were the most common. EX-LE4 and ST35 (=EX-LE5) acupoints were most frequently selected in treatment. Among the evaluation indexes, a total efficacy rate was used the most. Most of fire needling groups showed more significant results compared with the manual acupuncture groups statistically. Conclusions : All studies showed that fire needling treatments for knee osteoarthritis were more effective than manual acupuncture treatments statistically. Therefore, the results of this study could be utilized as a preliminary data for another clinical research on fire needling treatment for knee osteoarthritis. However, further well-designed randomized controlled trials will be needed to develop sufficient evidence about the effectiveness and safety of fire needling treatment for knee osteoarthritis in the future.

Case Study on the Analysis of Disaster Vulnerabilities (Focused on the Fire & Explosion in the N-Industrial Complex) (재난 취약성 분석에 관한 사례연구(N공단의 화재·폭발을 중심으로))

  • Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.94-100
    • /
    • 2021
  • In general, the industrial complex is a place where factories of various industries are concentrated. It is only as efficient as it is designed. However, the risks vary as there are various industries. These features are also associated with various types of disasters. The dangers of natural disasters such as a typhoon, flood, and earthquake, as well as fire and explosions, are also latent. Many of these risks can make stable production and business activities difficult, resulting in massive direct and indirect damage. In particular, decades after its establishment, the vulnerabilities increase even more as aging and small businesses are considered. In this sense, it is significant to assess the vulnerability of the industrial complex. Thus analysing fire and explosion hazards as stage 1 of the vulnerability evaluation for the major potential disasters for the industrial complex. First, fire vulnerabilities were analyzed quantitatively. It is displayed in blocks for each company. The assessment block status and the fire vulnerability rating status were conducted by applying the five-step criteria. Level A is the highest potential risk step and E is the lowest step. Level A was 11.8% in 20 blocks, level B was 22.5% in 38 blocks, level C was 25.4% in 43 blocks, level D was 26.0% in 44 blocks, and level E was 14.2% in 24 blocks. Levels A and B with high fire vulnerabilities were analyzed at 34.3%. Secondly, the vulnerability for an explosion was quantitatively analyzed. Explosive vulnerabilities were analyzed at 4.7% for level A with 8 blocks, 3.0% for level B with 5, 1.8% for level C with 3, 4.7% for level D with 8, and 85.8% for level E with 145. Levels A and B, which are highly vulnerable to explosions, were 7.7 %. Thirdly, the overall vulnerability can be assessed by adding disaster vulnerabilities to make future assessments. Moreover, it can also assist in efficient safety and disaster management by visually mapping quantified data. This will also be used for the integrated control center of the N-Industrial Complex, which is currently being installed.

An effective prevention facilities for railway tunnel design by using Quantitative Risk Analysis (효율적 방재시설을 위한 정량적 위험도 분석)

  • Kwon, Soon-Sub;Shin, Hwa-Cheol;Jung, Ji-Seung;Min, Dae-Hing
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1080-1084
    • /
    • 2007
  • Recently, as demands of new railway and the relocation of existing line, a number of tunnel structures have been constructed. Tunnel structures contribute to minimize the cost and time of transport, but in case of railway fire accident bring serious damages of human life caused by narrowness of shelter, smoke and high temperature, difficulty in rescue. For that reason, at the beginning of plan of tunnel, the optimum design of safety facility in tunnel for minimizing the risks and satisfying the safety standard is needed. In this study, QRA(Quantitative Risk Analysis) technique is applied to design of railway tunnel for assuring the safety function and estimating the risk of safety. The case study is carried out to verify the QRA technique for railway tunnels in Iksan-Sili.

  • PDF

Evaluation of Human Factors in Ship Accidents in the Domestic Sea (국내 해양선박사고의 인적 오류의 요인 평가)

  • Kim, Dong-Jin;Kwak, Su-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.87-98
    • /
    • 2011
  • In this study, we investigated and identified criterial human factors(errors), most of which lead to terrible ship accidents such as collisions, sinking, fire and explosions resulting both in human lives and physical damages to ships as well as surrounding environments. To this end, we went through the accident reports of 413 cases over 2005~2009 period and classified the human factors into 6 major factors with 19 sub ones which were constructed in hierarchical order. The relative importance of major factors was calculated and among others the lack of awareness turned out to be the most important factor with the weight of 0.391. The contributions of the results in the research are two fold: it will help (i) identify the root causes of ship accidents and prevent further potential ship related incidents, (ii) analyze the degree of the risk associated with the ship accidents, when risk analysis is performed.

Investigation of Potential Fire Hazard Resources of Bridges on National Routes by Field and Web-based Satellite (현장 및 실내조사를 통한 일반국도교량의 화재위험요소 분석)

  • Kim, Yongjae;Kim, Seungwon;Ann, Hojune;Kong, Jungsik;Park, Cheolwoo
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.105-115
    • /
    • 2017
  • PURPOSES : The occurrence of unexpected disasters, including fire events, increases as the road network becomes complicated and traffic volume increases. When a fire event occurs on and under bridges, the damage extensively influences direct damage to structures, vehicles, and human life and secondary socioeconomic issues owing to traffic blockage. This study investigated potential fire-hazard risks on bridges of the Korean national route road. METHODS : The investigation was conducted using field investigation and analysis with satellite pictures and road views from commercial websites and the Bridge Management System (BMS). From the filed investigation, various potential fire resources were identified. The satellite pictures and road views were helpful in measuring and recognizing conditions underneath bridges, stowage areas, etc. RESULTS : There are various potential fire resources underneath bridges such as piled agricultural products, parked petroleum tanks, construction equipment, and attached high-voltage cables. A total of 94.6% of bridges have underneath clearances of less than 15 m. A bridge underneath volume that can stow a potential fire hazard resource was $7,332m^3$ on average, and most bridges have about $4,000m^3$ of space. Based on the BMS data, the amounts of PSC and steel girders were 29% and 25%, respectively. CONCLUSIONS : It was found that the amount of stowed potential fire hazard resources was proportional to the underneath space of bridges. Most bridges have less than 15 m of vertical clearance that can be considered as a critical value for a bridge fire. The fire risk investigation results should be helpful for developing bridge fire-protection tools.

A study on the Risks of Using Filtration Facilities at the Organic Light Emitting Diode(OLED) and Its Preventive Measures (유기발광다이오드(OLED) 소재 제조 현장 여과 설비사용 위험성 및 개선 방안 연구)

  • Jong-Ku Kwak;Chankyu Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.1-11
    • /
    • 2023
  • The size of the OLED material market is expected to grow from $1.1 billion in 2019 to $2.3 billion in 2023, with an average annual sustainable growth of more than 19%. Among the facilities mainly used by OLED material manufacturers, accidents such as fire, explosion, and leakage frequently occur when using filtration equipment, so it is necessary to improve the risk when using filtration equipment. In this study, it was divided into four main processes, namely, assembly and disassembly process, filtration process, wet cake recovery process, and washing process in order to derive the risks associated with the use of filtration equipment. Hazard factors were derived by conducting accident case investigations, preliminary interviews, and surveys. For the analysis of questionnaire results, statistical analysis such as frequency analysis and Pearson chi-square test analysis was performed using SPSS 21, and risk improvement measures were suggested using the analyzed results. It is expected that this study will serve as a basis for dealing with safety and risk factors that may occur as the size of the OLED market expands.

Assessing the risk of work-related musculoskeletal disorders in 119 EMT: a focus on patient-carrying tasks (119구급대원의 업무 관련성 근골격계 질환 위험성 평가 : 환자 운반 작업을 중심으로)

  • Jeong-Won Son
    • The Korean Journal of Emergency Medical Services
    • /
    • v.27 no.3
    • /
    • pp.33-46
    • /
    • 2023
  • Purpose: This study aims to evaluate the risk of work-related musculoskeletal disorders (WMSDs) in 119 EMT during patient-carrying tasks using a long backboard (LBB) and a variable stretcher. Methods: Manikins were used as patients, and 45 new 119 EMT from K Fire Academy were filmed performing patient-carrying tasks on stairs. The tasks were analyzed using Ovako working posture analysis system (OWAS) and Rapid entire body assessment (REBA). Results: In using LBB, the OWAS score was Mode 3(Mean 2.37, Maximum 3), requiring as soon as possible corrective action, the REBA score was Mode 11(Mean 9.16, Maximum 11), requiring immediate improvement. In using variable stretcher, the OWAS score was Mode 1(Mean 2.33, Maximum 3), non-necessity for corrective action, the REBA score was Mode 9(Mean 8.0, Maximum 11), requiring as soon as possible. Conclusion: In conclusion, improvement was needed in one task (carrying a patient using a LBB) in the OWAS and in two tasks (carrying a patient using a LBB, carrying a patient using a variable stretcher) in the REBA. Thereby, required attention and management of WMSDs during training. In addition, it is essential to carry out objective and quantitative assessments through ergonomic analysis by occupational health professionals when designing future training programs to prevent WMSDs.