• 제목/요약/키워드: Fire Protection Rate

검색결과 188건 처리시간 0.023초

산업재해 예방을 위한 재정지원사업의 수요자 설문조사를 통한 제도적 개선방안 연구 (A Study on the Institutional Improvement Plan through Consumer Survey of Financial Support Programs for Industrial Accident Prevention)

  • 배동철
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.62-71
    • /
    • 2018
  • The purpose of this study is to conduct surveys on demanders using financial aid projects to prevent industrial accidents and to improve them. It is divided into clean business and loan support business through the structured questionnaire. In the case of clean business, the following results were obtained. Most of the applications were received within three months after application. The most important factor considered by the consumer is the amount of support, which is considered to consider the substantial improvement as follows.The expectation for the reduction of industrial accidents after the project was 96.1% and compared to before and after the actual business, it showed a 46.8% decrease from the previous year. In addition, the cost decreased by 21.8%, the facility utilization rate increased by 24.4%, the sales increased by 15.9%, and the average number of workers increased by 6.0. As for the sustainability of the business, 86.6% of the respondents said that they should continue to do so. The following results were obtained in the case of loan support projects. Industrial accidents decreased by 45.2% from the previous year. Costs decreased by 19.4%, facility utilization rose by 26.7%, sales increased by 14.9%, and the number of workers increased by an average of 2.8. In the case of suppliers, prevention of industrial accidents at the business sites participating in the clean business was the highest factor (67.0%). 89% of respondents were aware of the disposal criteria for ineligible suppliers. 50.6% of the respondents answered that it is appropriate to maintain the current level, and 39.4% of respondents answered that they should strengthen. The prices for the support items were more than 15% higher than the market prices.

기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구 (A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System)

  • 구재현
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 연구는 실내 쾌적성 제어를 위하여 룸 에어컨의 환기성능을 분석한다. 실험장치는 환경공조챔버, 룸 에어컨, 추적가스 측정시스템, 급기팬과 제어기로 구성된다. 환기성능은 ASTM Standard E741-83 기준에 근거하여 환경공조챔버 내 CO2 추적가스기법을 사용한 체강법에 의해 재실자와 급기 환기량에 따라 평가된다. 급기 환기량 증가에 따라 환기성능이 증가함을 파악하였으며 재실자가 없는 경우 CO2 가스는 빠르게 감소하며 이때의 환기성능은 55%까지 증가한다. 그리고 1명의 재실자가 있는 경우 1시간 경과후 급기량 570 lpm에서 환기성능은 자연감쇠와 비교하여 25%까지 증가한다. 실험 데이터를 사용하여 환경공조챔버 내 룸 에어컨의 환기성능 모델링을 도출하였다.

원형 물탱크내의 격벽수에 따른 유동장 해석 (Analysis of Flow Field in the Circular Water Tank According to the Number of Baffles)

  • 김정환;강동열;정태준;김세영;최종욱;추병길
    • 대한환경공학회지
    • /
    • 제31권1호
    • /
    • pp.15-20
    • /
    • 2009
  • 정수장에서 사용되고 있는 원형 물탱크내의 물은 잔류염소농도 0.1 mg/L 이상을 유지하여야 한다. 일반적으로 잔류염소 농도는 물탱크의 구조, 크기 그리고 물의 유량에 따라 다르다. 잔류염소농도는 염소의 확산시간을 최대한 확보하는 것이 가장 중요하며, 그것을 위하여 일반적으로 원형 물탱크내의 격벽을 설치한다. 본 연구에서는 수치해석을 이용한 유동해석을 수행하여 물과 염소의 농도분포를 구하였다. 유동해석 결과 격벽사이에서 유동내 와류가 발생하였으며, 격벽의 수가 증가할수록 염소가 물에 확산되는 시간을 확보할 수 있었다.

사무소 건물 태양열급탕시스템의 LCC 최적화에 따른 에너지성능 변화 분석 (Energy Performance Variation of Solar Water Heating System by LCC Optimization in an Office Building)

  • 고명진;최두성;장재동;김용식
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.89-98
    • /
    • 2011
  • This study examined the energy performance according to the main design parameters of a solar water heating system for an office building using the life cycle cost (LCC) optimization simulations. The LCC optimization simulations of the system were conducted with TRNSYS and GenOpt employing the Hooke-Jeeves algorithm for cases where water temperature was $60^{\circ}C$ and $50^{\circ}C$. The results showed that for water temperature at $60^{\circ}C$ and $50^{\circ}C$ the global radiation incident on the collector could be decreased by 16.98% and 28.52%, collector useful energy gain could be decreased by 15.04% and 22.59%, energy to load from storage tank could be decreased by 10.86% and 18.06% and AH energy to load could be increased by 16.86% and 38.50% respectively compared to a non-optimized system. The annual average collection efficiency of the collector was increased by 0.88% for $60^{\circ}C$ and 2.78% for $50^{\circ}C$ because of increase of collector slope and decrease of the mass flow rate per collector area. The annual average efficiency of the system was increased by 1.74% and 3.47% compared to the basis system. However, the annual solar fraction of the system was decreased by 6.68% for $60^{\circ}C$ and 11.26% for $50^{\circ}C$ due to decrease of collector area and storage tank volume.

금속제조업 재해 현황과 안전의식에 관한 연구 (A Study of Metal Manufacturing Disaster Situation and Safety Consciousness)

  • 전관옥;이신복;이동호
    • 문화기술의 융합
    • /
    • 제4권4호
    • /
    • pp.429-438
    • /
    • 2018
  • 최근 제조업에서 발생하고 있는 사고로 인하여 중대 재해 및 중대 산업사고로 이어지고 지역사회 재난으로까지 확대되는 경향을 나타내고 있다. 안전행정부는 제3차(2015-2019)국가안전관리기본계획에 따라 산업현장 재해 및 재난을 최소화하기 위한 기업재난관리 차원의 개선대책을 발표하고 적극 홍보하고 있다. KOSHA 2015~2017년도의 산업재해 발생 현황을 보면 금속 관련 제조업의 재해율이 1.57%로 전 업종 평균 0.50% 대비 약 3배 이상 높게 나타났다. 재해 원인을 조사해 본 결과 작업자의 불안전한 행동에 기인하여 발생된 비율이 72%로 높게 나타났다. 또한 불완전한 행동은 안전의식과 밀접한 관계를 가지고 있어 이 분야에 종사하고 있는 작업자를 대상으로 안전의식에 대한 설문조사를 실시하였다. 안전의식이 사고 예방에 가장 긍정적인 영향을 미치고 있고 사고발생을 감소시키는 요인으로 나타났다.

인-질소 첨가제로 처리된 시험편의 연소 시에 발생하는 일산화탄소와 이산화탄소 생성 (Emission of Carbon Monoxide and Carbon Dioxide Gases during Fire Tests of Specimens Treated with Phosphorus-Nitrogen Additives)

  • 정영진
    • 공업화학
    • /
    • 제26권5호
    • /
    • pp.609-614
    • /
    • 2015
  • 이 연구에서는 피로인산/4암모늄이온, 메틸렌피페라지노메틸-비스-포스폰산, 메틸렌피페라지노메틸-비스-포스폰산/4암모늄이온의 화학 첨가제로 처리된 리기다 소나무의 연소독성가스의 생성을 고찰하였다. 15 wt%의 화학 첨가제 수용액으로 각각 리기다 소나무에 3회 붓칠하여 실온에서 건조시킨 후, 콘칼로리미터(ISO 5660-1)를 이용하여 연소독성가스의 생성을 시험하였다. 그 결과, 화학 첨가제로 처리한 시험편의 1차-최대질량감소율도달시간(1st-$TMLR_{peak}$)은 무처리 시험편에 비교하여 (66.7~250.0)%의 지체된 시간을 나타내었다. 반면에 첨가제로 처리한 시험편에 대한 최대일산화탄소 생성($CO_{peak}$), (0.0136~0.0178)% 및 최대이산화탄소 생성($CO_{2\;peak}$), (0.04432~0.3648)%은 공시험편보다 높게 나타났다. 특별히 $O_2$의 생성농도는 사람에게 치명적일 수 있는 수준인 15%보다는 훨씬 높으므로 그로 인한 위험성은 배제할 수 있었다. 그러나 화학 첨가제로 처리한 시험편은 처리하지 않은 시험편과 비교하여 연소-유독성을 부분적으로 증가시켰다.

알루미늄 합성수지 복합 구조 스프링클러 파이프의 변위 흡수 특성 연구 (A Study on the Plastic deformation Absorption Characteristics of Aluminum-Polyethylene Composite Structure Sprinkler Pipe)

  • 김준곤;김광범;노성여
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.426-433
    • /
    • 2019
  • 지진의 2차사고 중 화재 및 가스 폭발에 의한 사고는 아파트형 주거 형태와 대형 복합화 된 건물이 많은 도시 일수록 인명피해의 우려가 커지게 되고, 이를 방지하기 위하여 화재 방호 계통 스프링클러 시스템의 경우 내진 설계가 필수적으로 수행되어야 한다. 하지만 현재 일반적으로 사용하고 있는 화재 방호 계통 스프링클러 시스템 배관은 대부분 스테인리스 계열의 금속 파이프를 사용하고 있고 일부 특수 위치에서 합성수지 계열의 파이프를 사용하고 있어 진동 및 지진 등에 취약한 소재가 적용되고 있다. 이에 본 연구에서는 폴리에틸렌(Polyethylene, 이하 : PE)과 알루미늄(Aluminum, 이하 : Al)의 다층구조 복합관이 보유한 변위 흡수 유연성이 진동 환경과 지진 발생에 대한 내진 성능을 상승 시키는 특성으로 판단하였고, PE-Al-PE 복합관을 기존 스테인리스 관, PE관과 비교하여 내진 성능을 실험 하였다. 내진 특성은 스프링클러 파이프가 전달하는 진동의 양과 범위를 측정하면 진동에 대한 흡수 정도를 알 수 있고 이는 지진에 대하여 대상체가 자체적으로 진동을 감쇠하는 내진 특성 판단의 방법으로 횡 형 진동 측정법으로 발생한 진동의 최초 응답 변위에 대한 대수 감쇠율을 비교하여 파이프의 내진 특성을 확인하였다.

경사도변화 계측을 통한 백제 송산리 고분군의 지하 벽체거동특성과 안정성 (Characteristics of Subsurface Movement and Safety of the Songsanri Tomb Site of the Baekje Dynasty using Tiltmeter System)

  • 서만철;박은주
    • 지질공학
    • /
    • 제7권3호
    • /
    • pp.191-205
    • /
    • 1997
  • 백제 시대의 대표적인 문화재들이 다수 출토된 무령왕릉을 포함한 송산리 고분군에 대한 고분벽체의 거동을 장기적으로 계측하여 분석하였다. 본 연구는 송산리 고분군의 안정성을 판단하여 보존대착을 수립하기위한 목적으로 이루어졌으며, 각 고분의 중요지점에 총 11개의 2축 경사변화측정센서를 설치하고 매 20분마다 자동계측하여 약 15개월 동안 (1996년 7월 14일~1997년 9월 30일) 관측을 실시하였다. 무령왕릉의 벽체거동은 연도입구의 호벽이 최대거동을 보여 직각변위(N-S Tilt) 성분이 2.3mm/m/yr로 남쪽방향인 전실쪽으로 거동하고 있는 것으로 밝혀졌다. 무령왕릉 현실 서측벽의 남쪽 등 상감 상부의 벽돌이 1971년 발굴 이후 남쪽으로 기울어진 병형을 보이며 고분구조가 남쪽 방향으로 거동함을 증명하고 있다. 현실 동측벽의 거동 또한 1.523mm/m/yr로 현실 내부로의 거동이 심한편이다. 더구나 우기에는 그 변위가 약 2배에 달하는 것으로 판단되어 고분군 주위의 지반이 침투수에 노출되는 우기에는 고분의 구조안전에 심각한 문제가 있는 것으로 판단된다. 5호분은 전체적으로 벽체의 전후방향 거동이 벽체의 전단방향 변위보다 크게 나타난다. 또한 틸트의 급격한 불연속은 없고 일정한 방향으로 계속적인 미약한 변동을 보이고 있다. 6호분 역시 건기의 최대 거동 수치가 8.8mm/m/yr로써 다른 고분의 우기시의 거동수치를 훨씬 초과한다. 고분벽체의 대.소의 변형 사건은 강수 및 온도변화와 밀접한 관련성이 있는 것으로 밝혀졌다. 온도변화에 의한 벽체거동의 영향은 고분내의 온도가 급격히 상승할 때는 온도가 일정하게 유지될 때보다 거동 비율이 훨씬 크다. 상승했던 온도가 다시 하강되면 벽체는 온도가 상승하기 전의 상태로는 돌아가지 않고 잔여변형을 발생시켜 영구변형으로 남게 되는 이력현상을 보이고 있다. 또한, 무령왕릉 주변의 지하수위 관측 결과 현재 고분축조부지의 배수체계가 원지반보다 불량함을 의미하여, 불량한 배수체계는 고분의 구조안전에 영향을 미치는 것으로 판단된다. 이와같이 고분군에 발생한 모든 변위들은 발굴 후 인위적인 환경변화와 지속적인 강우침투의 영향과 배수불랴으로 인한 주변지반 및 내벽의 물성치의 저하로 인하여 고분의 내벽에 상당량의 변위가 발생한 것으로 판단된다. 무령왕릉 벽체거동 특성 분석 결과 무엇보다 강우침투 및 지아수유입을 막는 차수대책이 시급하며, 고분내에 있는 제습기에 의한 상승효과흐 제거하여야 할 것으로 판단된다.

  • PDF