• Title/Summary/Keyword: Fire Protection Rate

Search Result 188, Processing Time 0.025 seconds

A Research on Thermal Properties & Fire Resistance of A Water Film Covered Glazing System for Large Atrium Space (대규모 아트리움에 적용되는 수박형성 유리벽의 열적 특성 및 내화성능에 관한 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.38-55
    • /
    • 1999
  • In order practically to use fire-defective glazing materials for the compartment wall where a fire-protection rating is mandated, there have been many trials internationally, This research focuses on a feasibility that, if certain water film covered all surface of glass, the glazing system can endure without breaking out under the compartment fire. First of all, a water film spray system was specially designed to wet the entire surface of the glass and also to have tiny small amount of water rebounded from the surface after emitted from nozzles. After this system has proven to have perfect performance, small-scale tests were done to find out if the water film covered glazing system react to the high temperature curve in a small furnace room. Finally, on basis of the obtained data, full-scale experiments were done so that water-film covered glazing system can pass the Korean Standard (KS) test for fire resistance, KS F2257.

  • PDF

Combustion Properties of Ethylene-propylene diene monomer/polypropylene/Clay Nanocomposites Based on EDPM/PP (EPDM/PP에 바탕을 둔 에칠렌-프로필렌 디엔 모노머/폴리프로필렌/클레이 나노복합체의 연소특성)

  • Chung, Yeong-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.410-417
    • /
    • 2011
  • Effects of ethylene-propylene diene monomer (EPDM)/polypropylene (PP), zinc oxide, stearic acid, and clay on the combustive properties based on EDPM/PP were investigated. The EDPM/PP/clay nanocomposites was compounded to prepare specimen for combustive analysis by cone calorimeter (ISO 5660-1). It was found that the specific mass loss rate (SMLR) in the nanocomposites decreased due to the fire resistance compared with unfilled EDPM/PP, while the nanocomposites showed the higher total heat release (THR), higher CO production release, and higher specific extinction area (SEA) than those of virgin EPDM/PP. The stearic acid for softening ruber increased the THR and amount of smoke by itself, combustible.

Evaluation of Combustion Characteristics of Outdoor Advertisement Materials (옥외 광고물 소재의 연소특성 평가)

  • Eom, Sang-Yong;Kim, Kyoung-Jin;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-84
    • /
    • 2012
  • Combustion characteristics of outdoor advertisement materials were evaluated for fire risk assessment about fire expanding. At this study, the flame retardancy and the limiting oxygen index (LOI) was measured by UL 94 and ASTM D 2863 respectively. At the result of flame retardancy, foamex was V-0 grade and those of others were out of grade. LOI measurement showed that the LOI of foamex was highest in the samples. The cone calorimeter test was done by ISO 5660-1 to find the combustion characteristics. The cone calorimeter test showed that the outdoor advertisement materials were not good to prevent of fire expanding. The time to ignition (TTI) of flex was the fastest and the peak heat release rate (PHRR) as well as the total heat release (THR) of acrylic panel was higher than those of others.

A Study on the Transition of Hydrogen-Air and LPG-Air Explosion to Fire (수소와 액화석유 가스의 공기혼합기의 폭발 후 화재로 전이 연구)

  • Oh Kyu-Hyung;Lee Sung-Eun;Rhie Kwang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.150-154
    • /
    • 2004
  • Gas explosion characteristics of hydrogen and liquefied petroleum gas(LPG) were measured in 6L cylindrical vessel, and experiment for explosion to fire transition phenomena of the gases were carried out using the 270L vessel. Explosion characteristics were measured using the stain type pressure transducer and explosion to fire transition phenomena was analyzed with the hish-speed camera. Base on the experiment, it was found that explosion pressure was most high slightly above the stoichiometric concentration, and explosion pressure rise rate and flame propagation velocity were proportional to the combustion velocity. And we find that those kind of explosion characteristics affect the explosion-to-fire transition, in addition, explosion flame temperature, flame residence time, are important parameters in explosion-to-fire transition.

Characteristics of Smoke Propagation in Railway Tunnels with Rescue Station (구난역을 갖는 철도 터널 내부의 연기거동 특성)

  • Jang, Won-Cheol;Kim, Dong-Woon;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.13-18
    • /
    • 2009
  • The main objective of the present study is to investigate smoke propagation in railway tunnels with rescue stations. In particular, based on measurement of HRR (heat release rate) for pool fires formed at different locations, the influence of fire source location on smoke behavior is examined. The fuel is n-heptane and pool fires are generated with a square length 4cm. With the use of MVHS (Modified Volumetric Heat Source) model for fire source, extensive numerical simulations are performed by using the commercial code FLUENT (Ver.6.3) Predicted smoke temperatures and smoke propagation are discussed. From numerical predictions, it is found that ventilation systems may be necessary in the railway tunnels because the smoke moves along the tunnel, and consequently it enters the non-accident tunnel. It is also confirmed that the cross-passage and fire protection wall systems contribute to control the smoke.

A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump (초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul;Sung, Gi-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Ultra-high pressure positive displacement pump can discharge high pressure water with mass volume, which depends on periodic changes in volume that made by rotation motor. Its high efficiency of discharge is one of the most strong point of positive displacement pump. Due to its simple system structure, it can be miniaturized and lightened. Positive displacement pump can discharge high pressure with stable flow rate, irrespective of pressure fluctuate. This is the reason that positive displacement pump was used instead of centrifugal pump. In this study, shutoff operating system was developed for positive displacement pump to secure safety of high pressure operate. This shutoff system contains controller system, electronic clutch, and relief valve, and each part is mutual supplementation. Speed test was carried out in order to check operation of controller program and electronic clutch and fluid flow, venting experiment of the relief valve. It was confirmed that segment system of ultra-high pressure positive displacement pump is operated.

Combustion Characteristics of Pinus rigida Specimens Treated with Phosphorus-Nitrogen Additives (인-질소 첨가제로 처리된 리기다 소나무 시험편의 연소특성)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.13-19
    • /
    • 2015
  • This study was performed to test the combustive properties of Pinus rigida specimens treated with phosphorus (P) and nitrogen (N) additives. Each Pinus rigida specimen was painted three times with 15 wt% P-N additive solutions at room temperature. After drying the treated specimens, the combustion properties were examined using a cone calorimeter (ISO 5660-1). The time to ignition (TTI) for the treated specimens was 90 to 148 s except for the specimen treated with PP/$4NH_4^+$, and the time to flameout (TF) was 556 to 633 s, which was longer than that of virgin plate. While the The specimens treated with P-N additives showed 12.5 to 43.4% higher mean heat release rate ($HRR_{mean}$) and 11.8 to 43.1% higher total heat release (THR) than virgin plate. The effective heat of combustion (EHC) was by 2.9 to 17.5% lower than that of virgin plate. It can thus be concluded that the combustion-retardation properties were partially improved compared to those of virgin plate.

Prediction of Poor Contact by Analysis of Electrical Signal and Thermal Characteristics (전기적 신호와 열적특성 분석에 의한 접촉불량 예측)

  • Lee, Heung-Su;Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.36-41
    • /
    • 2012
  • Electrical Connections often cause fires due to poor contact. Occurrence rate of these fires tends to increase annually. The reason why poor contacts occur is often because it is the low mechanical pressure at the contact points. A typical connection method using mechanical pressure is a screw terminal type. This study reviewed these poor contact cases in the screw terminals. In order to get reproduction of such cases, two types of experiments were conducted. the first one was conducted under the normal contact condition, and the other one was conducted under the poor contact condition that screw terminal of breaker was loosen and did not meet the requirements of toque value. In both types of experiments, compulsory vibration was adopted as a variable to aggravate poor contacts. Each of various current values(4.5A, 9.0A, 13.5A) is input. In these experiments, relationships of a contact, electrical signal such as current and electric pulse by ZCT and thermal characteristics according to vibration effect are analyzed. The suggested data and results in this study provide the useful resources helping to investigate fires due to poor contact, and they develop the detector for poor contact and finally reduce the electrical fire occurrence rate.

Combustion-Retardation Properties of Low Density Polyethylene and Ethylene Vinyl Acetate Mixtures with Magnesium Hydroxide (수산화마그네슘이 첨가된 저밀도 폴리에틸렌과 에틸렌 비닐 아세테이트 혼합물의 난연성)

  • Chung, Yeong-Jin;Lim, Hyung Mi;Jin, Eui;Oh, JungKyoo
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.439-443
    • /
    • 2011
  • It was performed to test the combustive properties of low density polyethylene and ethylene vinyl acetate (LDPE-EVA) mixture by the addition of magnesium hydroxide. Flame retardant of natural magnesium hydroxide was added to the mixture of LDPE-EVA in 40 to 80 wt% concentration. The composite was compounded to prepare specimen for combustive analysis by cone calorimeter (ISO 5660-1). Comparing with virgin LDPE-EVA, the specimens including the magnesium hydroxide had lower combustive properties. It is supposed that the combustion-retardation properties in the composites improved due to the endothermic decomposition of magnesium hydroxide. The specimens with magnesium hydroxide showed both the lower peak heat release rate (PHRR) and lower effective heat of combustion (EHC) than those of virgin polymer. As the magnesium hydroxide content increases, time to ignition increased and the peak heat release rate decreased.

A Study on the Explosion Characteristics of by Product Gas of Carbon Black Manufacturing Process (카본블랙 제조 부생가스의 폭발 특성연구)

  • Oh Kyu-Hyung;Lee Sung-Eun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.60-64
    • /
    • 2006
  • Explosion range and explosion characteristics of by product gas from carbon black manufacturing process were studied. About 75% of the by product gas were composed with water vapour and nitrogen. And the combustible component in the gas were hydrogen, methane, acetylene and carbon mono-oxide. Because of the combustible components in the by product gas there are explosion hazards in the gas handling process. Explosion range of the gas by experiment was from 17.1% to 70.7% and the value has considerable difference with the calculated value from Lechatelier law. Explosion pressure of the gas was $5.4kg/cm^2$ and the average explosion pressure rise rate was $39.2kg/cm^2/s$. Based on the experimental result we can expect that a explosion or fire accident during the handling the gas can make a severe loss, therefore there should be a explosion prevention or protection measures in the gas handling process.

  • PDF