• Title/Summary/Keyword: Fire Protect System

Search Result 78, Processing Time 0.026 seconds

The Report on Test Results of CO Fire Extinguishing System ($CO_2$ 소화설비 구성부품 성능시험보고)

  • Kim, Gi-Ok;Lee, Chan-Ju;An, Byeong-Ho
    • Fire Protection Technology
    • /
    • s.14
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

Imporovement Plan of Fire Inspection System (소방검사제도의 개선방안)

  • Lee, Jong-Young;Ki, Tae-Geun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.181-195
    • /
    • 2009
  • Modern constitution obtains its justice by protecting the people's basic legal rights. The constitutional rights can be more than a defensive measure against government power by modern viewpoints. The government has to create an atmosphere which the rights are not violated. The Constitution provides that the government has to make efforts to prevent disaster and protect the people from danger in Clause 34, Art. 6. The government has an obligation to protect the people's basic legal rights of life, health and property from fire damages, and those rights are gathering strength under a socialist state principle as fundamental ideology of modern societies. The present fire inspection system gains a point constitutionally but it still needs to be certified as the most suitable system. This article examines the solution to operate fire inspection system efficiently, given the reality of present system operation. It is necessary to improve the system by integrating the present fire inspection with the self fire inspection. Government needs to re-modification the Fire inspections system for prevent and promote (resolve) the problem which government officer (ex fire fighter) can make a irregularities and corruption as do it oneself.

A Study On fire Detecting Technologies in Subway and Fire protection methodologies (지하철 역사의 화재조기감지방법 및 내화대책에 대한 연구)

  • Yang, Tae-Seon;Kim, Eun-Chong;Lee, Euig-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.314-319
    • /
    • 2005
  • Nowadays, there so many fire accidents happened in subways and tunnels, buildings. In this paper, the behaviors of subway damaged by fire, the fire protection techniques for evaluating subway structures stability are presented. To protect the tunnel by fire, flame detector method is resonable.

  • PDF

A Study of Prevention Management System Model and Fire Safety Diagnose for Cultural Heritages -Based on Traditional wooden structure in kyong gi-Do- (중요문화재의 소방안전 진단 및 예방관리 시스템 모델 연구 -경기도내 전통적인 목조건축물 중심으로-)

  • 정길흥
    • Journal of the Korean Professional Engineers Association
    • /
    • v.32 no.6
    • /
    • pp.148-157
    • /
    • 1999
  • As cultural Heritages are source of the national history and a life transition, their extinction is a fatal shock as result of cutoff the genealogy of the creative national spirit. So, we have necessarily to protect them, and to get the duty and the responsibility which the cultural inheritance hands over tnem to descendants with preserving and meaning safely at present time. In these days, the risk of fire in the Cultural Heritages building is increased because of rash changing environments from the indiscreet development of them. Accordingly, in order to get the original transmission of the Cultural Heritages, this paper involves being intensive the fire safety information of the Cultural Heritage in kyonggi-do province, analyzing their diagnoses, and studying a Fire Safety Prevention Management model to protect and to maintain them continuously. Therefore, it is to contribute from this approach to collecting fire safety information, analyzing diagnostic problems in fire accidents, and to manage the prevention method for protecting and maintaining the Cultural Heritages.

  • PDF

Study on Improvement of Fire Investigation System (화재조사제도 개선방안에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.101-110
    • /
    • 2009
  • As the current fire investigation system in Korea has been performed mainly by the public sector such as fire service, police, etc., private fire investigation system such as 'private fire investigator system' to protect rights and interests of the sufferers from the fire accidents due to defective products showed very deficient. In addition, since the laws and regulations concerned about fire investigation are distributed into and applied for each organization, a lot of problems have been generated such as civil appeals due to duplicated investigations among similar organizations, excess reaction to exclude other organization from the fire investigation field, inefficient waste of administration force due to duplicated operation of fire investigation organization and manpower, etc. This study has surveyed generation operation conditions and problems of the fire investigation system in Korea and drawn its improvement method on the public and private sectors.

Development of a precision smoke particle detector to sense a fire in early state (초기화재 감지를 위한 정밀한 연기 입자 감지 장치 개발)

  • 김희식;김영재;이호재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1734-1737
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of somke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility form the fire. We need to develope a new high precision smoke detection system to keep expensive industrial facilities most reliably form fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke particles in the air. It is operated continously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities, such as power plants, underground common tunnel, main control rooms, computer rooms etc.

  • PDF

Development of DC Arc Generator to protect against Malfunctions and Fires caused by Arcing (아크 발생에 따른 고장 및 화재를 보호하기 위한 직류 아크 Generator 개발)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.123-128
    • /
    • 2021
  • As the spread of DC power distribution systems increases, the occurrence of failures and fire accidents are also increasing. In particular, the ESS fire accident, which is a component of the smart grid, and the fire accident of the solar power system, which is a direct current system, are caused by problems in the electrical connection between system components as the supply of new and renewable energy rapidly increases and old facilities increase. An arc that can cause a direct fire by releasing the induced light and heat has been pointed out as one of the causes of fire. Therefore, the problem of such an arc defect is that it is impossible to block an arc accident in advance with the existing overcurrent circuit breaker and earth leakage circuit breaker. In this paper, we intend to develop a test equipment that satisfies international standardization and to develop a DC arc generator to protect against failure and fire caused by arcing.

Fire test procedures for flammability of bulkhead, ceiling and deck finish materials (선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법)

  • Kim, S.Y.;Kim, D.S.;Ahn, B.H.;No, H.S.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.157-159
    • /
    • 2007
  • It is very important to protect life, property at sea from any fire. Recommendation on improved fire test procedures for surface flammability of bulkhead ceiling and deck finish materials specifies a procedure for measuring fire characterizing their flammability and thus their suitability for use in marine construction. In this paper we investigated the positive expected by fire test procedures for flammability of bulkhead ceiling and deck finish materials. Also, unusual materials were analyzed. Finally, we suggest methods to solve several problems related to unusual materials.

  • PDF

Consideration on Fire-prevention Facilities for Wooden Cultural Heritages (목조문화재 보존을 위한 소방시설에 대한 고찰)

  • Kim, Tae-Goo
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.155-171
    • /
    • 2010
  • Wooden cultural heritages have many factors of fires and structural characteristics vulnerable to the fire extinguishing. Also, they are surrounded with forests and so remote from fire stations, which make it difficult to handle it quickly when fires break out. Wooden cultural heritages made of wood materials belong to the general fire in a Class A. Taking characteristics such as a smoldering and a backfire from the that fire of wooden materials into consideration, extinguishing the fire by the cooling system is the most effective. If the fire can't be put out at the early stage, it is almost impossible to protect wooden cultural heritages from the fire, because wooden structures can be destroyed in a high temperature and in a short time and it takes around average 7 minutes to reach its peak of flames in the process of a fire. According to the geographical and environmental situation of the cultural heritages, currently, the fire-prevention facilities such as the auto fire detector for the prompt detection, the water mist fire suppression system for the 1st early and urgent fire suppression and the outdoor fire hydrant and the water curtain etc. for the 2nd full-scale suppression and the prevention of the fire gaining force are being installed for the wooden cultural heritages.

  • PDF

연기농도 계측용 광학식 미세입자 감지장치 개발

  • 김영재;김희식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.128-132
    • /
    • 1997
  • The conventional fire detection devices are operated after a processed fire phase, which are sensing only a high density of smoke level or high temperature heat. They are not so precision to detect a fire in the early phase to protect the facility from the fire. We need to develope a new high precision smoke detection system to keep expensive industial facilities most reliably from fire. A new optical precision smoke detection system was developed. It monitors very low level density of smoke psrticles in the air. It is operated continuously through many years without a stop or any malfunction. The developed precision smoke detection system will be installed in important industrial facilities,such as power plants, underground common tunnel,main control rooms,computer rooms etc.

  • PDF